Determination of trehalose-6-phosphate in Arabidopsis seedlings by successive extractions followed by anion exchange chromatography-mass spectrometry

被引:31
作者
Delatte, Thierry L. [1 ]
Selman, Maurice H. J. [1 ]
Schluepmann, Henriette [2 ]
Somsen, Govert W. [1 ]
Smeekens, Sjef C. M. [2 ]
de Jong, Gerhardus J. [1 ]
机构
[1] Univ Utrecht, Dept Biomed Anal, NL-3584 CA Utrecht, Netherlands
[2] Univ Utrecht, Dept Mol Plant Physiol, NL-3584 CH Utrecht, Netherlands
关键词
Trehalose-6-phosphate; Anion exchange chromatography; Mass spectrometry; Arabidopsis thaliana; Solid-phase extraction; Liquid-liquid extraction; SUGAR PHOSPHATES; STARCH SYNTHESIS; TREHALOSE; 6-PHOSPHATE; REDOX ACTIVATION; METABOLITES; PYROPHOSPHORYLASE; QUANTIFICATION; SUCROSE; PATHWAY;
D O I
10.1016/j.ab.2009.03.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for the detection of trehalose-6-phosphate (T6P) in tissue of the model plant Arabidopsis thaliana is presented. Liquid-liquid extraction (LLE) and mixed mode solid-phase extraction (SPE) were used for sample pretreatment followed by anion exchange chromatography (AEC) coupled with electrospray ionization mass spectrometry (MS) for highly selective quantitative analysis. LLE of plant material was performed with chloroform/acetonitrile/water (3:7:16, v/v/v) followed by SPE with Oasis MAX material, which significantly reduced the complexity of the extracts. On-line coupling of MS with gradient AEC Using a sodium hydroxide eluent was accomplished with a postcolumn ion suppressor. The method allows specific quantification of T6P with good linearity for spiked plant extracts, from 80 nM to 1.3 mu M (r(2) > 0.98). The limit of detection in plant extracts was 40 nM. The recovery of the method was above 80% for relevant T6P levels. The method was applied to the determination of TGP in seedlings from four Mutant A. thaliana lines (TRR1-4) resisting growth arrest Caused by external supply of trehalose. Results reveal that T6P accumulation differed Substantially in the four mutant lines and wild type (WT). It is (concluded that the Mutants Circumvent the growth arrest observed in WT seedlings on 100 mM trehalose by different mechanisms. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:12 / 17
页数:6
相关论文
共 28 条
[1]   Hydrophilic interaction chromatography/electrospray mass spectrometry analysis of carbohydrate-related metabolites from Arabidopsis thaliana leaf tissue [J].
Antonio, Carla ;
Larson, Tony ;
Gilday, Alison ;
Graham, Ian ;
Bergstroem, Ed ;
Thomas-Oates, Jane .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (09) :1399-1407
[2]   Quantification of sugars and sugar phosphates in Arabidopsis thaliana tissues using porous graphitic carbon liquid chromatography-electrospray ionization mass spectrometry [J].
Antonio, Carla ;
Larson, Tony ;
Gilday, Alison ;
Graham, Ian ;
Bergstroem, Ed ;
Thomas-Oates, Jane .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1172 (02) :170-178
[3]   Analysis of carbohydrates by anion exchange chromatography and mass spectrometry [J].
Bruggink, C ;
Maurer, R ;
Herrmann, H ;
Cavalli, S ;
Hoefler, F .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1085 (01) :104-109
[4]   Oligosaccharide analysis by capillary-scale high-pH anion-exchange chromatography with on-line ion-trap mass spectrometry [J].
Bruggink, C ;
Wuhrer, M ;
Koeleman, CAM ;
Barreto, V ;
Liu, Y ;
Pohl, C ;
Ingendoh, A ;
Hokke, CH ;
Deelder, AM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 829 (1-2) :136-143
[5]   Quantification of intracellular metabolites in Escherichia coli K12 using liquid chromatographic-electrospray ionization tandem mass spectrometric techniques [J].
Buchholz, A ;
Takors, R ;
Wandrey, C .
ANALYTICAL BIOCHEMISTRY, 2001, 295 (02) :129-137
[6]   Polysaccharides analysis of sinorhizobial capside by on-line anion exchange chromatography with pulsed amperometric detection and mass spectrometry coupling [J].
Chataigne, G. ;
Couderc, F. ;
Poinsot, V. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1185 (02) :241-250
[7]   Improved protocols for quantitative determination of metabolites from biological samples using high performance ionic-exchange chromatography with conductimetric and pulsed amperometric detection [J].
Groussac, E ;
Ortiz, M ;
François, J .
ENZYME AND MICROBIAL TECHNOLOGY, 2000, 26 (9-10) :715-723
[8]  
Jensen NBS, 1999, BIOTECHNOL BIOENG, V63, P356, DOI 10.1002/(SICI)1097-0290(19990505)63:3<356::AID-BIT12>3.0.CO
[9]  
2-1
[10]   Determination of sugar phosphates by high-performance anion-exchange chromatography coupled with pulsed amperometric detection [J].
Jeong, Ji-Seon ;
Kwon, Ha-Jeong ;
Lee, Yong-Moon ;
Yoon, Hye-Ran ;
Hong, Seon-Pyo .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1164 (1-2) :167-173