Intracranial vessel segmentation from time-of-flight MRA using pre-processing of the MIP Z-buffer: accuracy of the ZBS algorithm

被引:30
作者
Chapman, BE
Stapelton, JO
Parker, DL
机构
[1] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15213 USA
[2] Univ Utah, Dept Radiol, Med Imaging Res Lab, Salt Lake City, UT 84108 USA
关键词
magnetic resonance angiography; segmentation; intracranial vessels;
D O I
10.1016/j.media.2003.12.002
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We evaluate the accuracy of a vascular segmentation algorithm which uses continuity in the maximum intensity projection (MIP) depth Z-buffer as a pre-processing step to generate a list of 3D seed points for further segmentation. We refer to the algorithm as Z-buffer segmentation (ZBS). The pre-processing of the MIP Z-buffer is based on smoothness measured using the minimum chi(2) value of a least square fit. Points in the Z-buffer with chi(2) values below a selected threshold are used as seed points for 3D region growing. The ZBS algorithm couples spatial continuity information with intensity information to create a simple yet accurate segmentation algorithm. We examine the dependence of the segmentation on various parameters of the algorithm. Performance is assessed in terms of the inclusion/exclusion of vessel/background voxels in the segmentation of intracranial time-of-flight MRA images. The evaluation is based on 490,256 voxels from 14 patients which were classified by an observer. ZBS performance was compared to simple thresholding and to segmentation based on vessel enhancement filtering. The ZBS segmentation was only weakly dependent on the parameters of the initial MIP image generation, indicating the robustness of this approach. Region growing based on Z-buffer generated seeds was advantageous compared to simple thresholding. The ZBS algorithm provided segmentation accuracies similar to that obtained with the vessel enhancement filter. The ZBS performance was notably better than the filter based segmentation for aneurysms where the assumptions of the filter were violated. As currently implemented the algorithm slightly under-segments the intracranial vasculature. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 126
页数:14
相关论文
共 20 条
[11]   CURVES: Curve evolution for vessel segmentation [J].
Lorigo, LM ;
Faugeras, OD ;
Grimson, WEL ;
Keriven, R ;
Kikinis, R ;
Nabavi, A ;
Westin, CF .
MEDICAL IMAGE ANALYSIS, 2001, 5 (03) :195-206
[12]   Improved vessel visualization in MR angiography by nonlinear anisotropic filtering [J].
Orkisz, MM ;
Bresson, C ;
Magnin, IE ;
Champin, O ;
Douek, PC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (06) :914-919
[13]   THE APPLICATION OF MAGNETIZATION-TRANSFER TO MR-ANGIOGRAPHY WITH REDUCED TOTAL POWER [J].
PARKER, DL ;
BUSWELL, HR ;
GOODRICH, KC ;
ALEXANDER, AL ;
KECK, N ;
TSURUDA, JS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) :283-286
[14]  
Parker DL, 2000, JMRI-J MAGN RESON IM, V11, P378, DOI 10.1002/(SICI)1522-2586(200004)11:4<378::AID-JMRI5>3.3.CO
[15]  
2-R
[16]  
ROBERTS JA, 2002, P ISMRM, P2471
[17]  
Rossnick S, 1986, P IEEE COMP CARD C I, P193
[18]  
Sato Y, 1998, Med Image Anal, V2, P143, DOI 10.1016/S1361-8415(98)80009-1
[19]  
TSURUDA J, 2002, P ISMRM, P1053
[20]   An adaptive segmentation algorithm for time-of-flight MRA data [J].
Wilson, DL ;
Noble, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (10) :938-945