Optimal Dose Levels in Screening Chest CT for Unimpaired Detection and Volumetry of Lung Nodules, with and without Computer Assisted Detection at Minimal Patient Radiation

被引:24
作者
Christe, Andreas [1 ]
Szucs-Farkas, Zsolt [2 ]
Huber, Adrian [1 ]
Steiger, Philipp [1 ]
Leidolt, Lars [1 ]
Roos, Justus E. [3 ]
Heverhagen, Johannes [1 ]
Ebner, Lukas [1 ]
机构
[1] Hosp & Univ Bern, Inselspital, Dept Radiol, Bern, Switzerland
[2] Hosp Ctr Biel, Dept Radiol, Biel, Switzerland
[3] Duke Univ, Dept Radiol, Durham, NC 27710 USA
关键词
SUBSOLID PULMONARY NODULES; AIDED DETECTION; MULTIDETECTOR CT; CONTRAST-MEDIUM; TOMOGRAPHY; ANGIOGRAPHY; PERFORMANCE; ACCURACY; GUIDELINES; PATTERNS;
D O I
10.1371/journal.pone.0082919
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
070301 [无机化学]; 070403 [天体物理学]; 070507 [自然资源与国土空间规划学]; 090105 [作物生产系统与生态工程];
摘要
Objectives: The aim of this phantom study was to minimize the radiation dose by finding the best combination of low tube current and low voltage that would result in accurate volume measurements when compared to standard CT imaging without significantly decreasing the sensitivity of detecting lung nodules both with and without the assistance of CAD. Methods: An anthropomorphic chest phantom containing artificial solid and ground glass nodules (GGNs, 5-12 mm) was examined with a 64-row multi-detector CT scanner with three tube currents of 100, 50 and 25 mAs in combination with three tube voltages of 120, 100 and 80 kVp. This resulted in eight different protocols that were then compared to standard CT sensitivity (100 mAs/120 kVp). For each protocol, at least 127 different nodules were scanned in 21-25 phantoms. The nodules were analyzed in two separate sessions by three independent, blinded radiologists and computer-aided detection (CAD) software. Results: The mean sensitivity of the radiologists for identifying solid lung nodules on a standard CT was 89.7%+/- 4.9%. The sensitivity was not significantly impaired when the tube and current voltage were lowered at the same time, except at the lowest exposure level of 25 mAs/80 kVp [80.6%+/- 4.3% (p = 0.031)]. Compared to the standard CT, the sensitivity for detecting GGNs was significantly lower at all dose levels when the voltage was 80 kVp; this result was independent of the tube current. The CAD significantly increased the radiologists' sensitivity for detecting solid nodules at all dose levels (5-11%). No significant volume measurement errors (VMEs) were documented for the radiologists or the CAD software at any dose level. Conclusions: Our results suggest a CT protocol with 25 mAs and 100 kVp is optimal for detecting solid and ground glass nodules in lung cancer screening. The use of CAD software is highly recommended at all dose levels.
引用
收藏
页数:11
相关论文
共 39 条
[1]
Lung cancer: Performance of automated lung nodule detection applied to cancers missed in a CT screening program [J].
Armato, SG ;
Li, F ;
Giger, ML ;
MacMahon, H ;
Sone, S ;
Doi, K .
RADIOLOGY, 2002, 225 (03) :685-692
[2]
Adult reference levels in diagnostic and interventional radiology for temporary use in Switzerland [J].
Aroua, A ;
Besançon, A ;
Buchillier-Decka, I ;
Trueb, P ;
Valley, JF ;
Verdun, FR ;
Zeller, W .
RADIATION PROTECTION DOSIMETRY, 2004, 111 (03) :289-295
[3]
Pulmonary nodules at chest CT: Effect of computer-aided diagnosis on radiologists' detection performance [J].
Awai, K ;
Murao, K ;
Ozawa, A ;
Komi, M ;
Hayakawa, H ;
Hori, S ;
Nishimura, Y .
RADIOLOGY, 2004, 230 (02) :347-352
[4]
Air trapping: Comparison of standard-dose and simulated low-dose thin-section CT techniques [J].
Bankier, Alexander A. ;
Schaefer-Prokop, Cornelia ;
De Maertelaer, Viviane ;
Tack, Denis ;
Jaksch, Peter ;
Klepetko, Walter ;
Gevenois, Pierre Alain .
RADIOLOGY, 2007, 242 (03) :898-906
[5]
Bongartz G., 2004, European guidelines for multislice computed tomography
[6]
Accuracy of low-dose computed tomography (CT) for detecting and characterizing the most common CT-patterns of pulmonary disease [J].
Christe, Andreas ;
Charimo-Torrente, Jaled ;
Roychoudhury, Kingshuk ;
Vock, Peter ;
Roos, Justus E. .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (03) :E142-E150
[7]
CT patterns of fungal pulmonary infections of the lung: Comparison of standard-dose and simulated low-dose CT [J].
Christe, Andreas ;
Lin, Margaret C. ;
Yen, Andrew C. ;
Hallett, Rich L. ;
Roychoudhury, Kingshuk ;
Schmitzberger, Florian ;
Fleischmann, Dominik ;
Leung, Ann N. ;
Rubin, Geoffry D. ;
Vock, Peter ;
Roos, Justus E. .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) :2860-2866
[8]
CT Screening and Follow-Up of Lung Nodules: Effects of Tube Current-Time Setting and Nodule Size and Density on Detectability and of Tube Current-Time Setting on Apparent Size [J].
Christe, Andreas ;
Torrente, Jaled Charimo ;
Lin, Margaret ;
Yen, Andrew ;
Hallett, Rich ;
Roychoudhury, Kingshuk ;
Schmitzberger, Florian ;
Vock, Peter ;
Roos, Justus .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) :623-630
[9]
Performance evaluation of a computer-aided detection algorithm for solid pulmonary nodules in low-dose and standard-dose MDCT chest examinations and its influence on radiologists [J].
Das, M. ;
Muehlenbruch, G. ;
Heinen, S. ;
Mahnken, A. H. ;
Salganicoff, M. ;
Stanzel, S. ;
Guenther, R. W. ;
Wildberger, J. E. .
BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (971) :841-847
[10]
Small pulmonary nodules:: Effect of two computer-aided detection systems on radiologist performance [J].
Das, Marco ;
Muehlenbruch, Georg ;
Mahnken, Andreas H. ;
Flohr, Thomas G. ;
Guendel, Lutz ;
Stanzel, Sven ;
Kraus, Thomas ;
Guenther, Rolf W. ;
Wildberger, Joachim E. .
RADIOLOGY, 2006, 241 (02) :564-571