Distortion and Signal Loss in Medial Temporal Lobe

被引:101
作者
Olman, Cheryl A. [1 ,2 ]
Davachi, Lila [3 ,4 ]
Inati, Souheil [3 ,4 ]
机构
[1] Univ Minnesota, Dept Psychol, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Radiol, Minneapolis, MN 55455 USA
[3] NYU, Dept Psychol, New York, NY 10003 USA
[4] NYU, Ctr Neural Sci, New York, NY 10003 USA
关键词
ECHO-PLANAR FMRI; GRADIENT-ECHO; HUMAN BRAIN; SPIN-ECHO; PHYSIOLOGICAL NOISE; SPATIAL-RESOLUTION; BOLD FMRI; 7; T; EPI; ARTIFACTS;
D O I
10.1371/journal.pone.0008160
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
070301 [无机化学]; 070403 [天体物理学]; 070507 [自然资源与国土空间规划学]; 090105 [作物生产系统与生态工程];
摘要
Background: The medial temporal lobe (MTL) contains subregions that are subject to severe distortion and signal loss in functional MRI. Air/tissue and bone/tissue interfaces in the vicinity of the MTL distort the local magnetic field due to differences in magnetic susceptibility. Fast image acquisition and thin slices can reduce the amount of distortion and signal loss, but at the cost of image signal-to-noise ratio (SNR). Methodology/Principal Findings: In this paper, we quantify the severity of distortion and signal loss in MTL subregions for three different echo planar imaging (EPI) acquisitions at 3 Tesla: a conventional moderate-resolution EPI (36363 mm), a conventional high-resolution EPI (1.5x1.5x2 mm), and a zoomed high-resolution EPI. We also demonstrate the advantage of reversing the phase encode direction to control the direction of distortion and to maximize efficacy of distortion compensation during data post-processing. With the high-resolution zoomed acquisition, distortion is not significant and signal loss is present only in the most anterior regions of the parahippocampal gyrus. Furthermore, we find that the severity of signal loss is variable across subjects, with some subjects showing negligible loss and others showing more dramatic loss. Conclusions/Significance: Although both distortion and signal loss are minimized in a zoomed field of view acquisition with thin slices, this improvement in accuracy comes at the cost of reduced SNR. We quantify this trade-off between distortion and SNR in order to provide a decision tree for design of high-resolution experiments investigating the function of subregions in MTL.
引用
收藏
页数:10
相关论文
共 46 条
[1]
Improved BOLD detection in the medial temporal region using parallel imaging and voxel volume reduction [J].
Bellgowan, PSF ;
Bandettini, PA ;
van Gelderen, P ;
Martin, A ;
Bodurka, J .
NEUROIMAGE, 2006, 29 (04) :1244-1251
[2]
Selection of voxel size and slice orientation for fMRI in the presence of susceptibility field gradients: application to imaging of the amygdala [J].
Chen, NK ;
Dickey, CC ;
Yoo, SS ;
Guttman, CRG ;
Panych, LP .
NEUROIMAGE, 2003, 19 (03) :817-825
[3]
Functional MR imaging using gradient-echo echo-planar imaging in the presence of large static field inhomogeneities [J].
Constable, RT .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (06) :746-752
[4]
Compensation of susceptibility-induced signal loss in echo-planar imaging for functional applications [J].
Cordes, D ;
Turski, PA ;
Sorenson, JA .
MAGNETIC RESONANCE IMAGING, 2000, 18 (09) :1055-1068
[5]
Item, context and relational episodic encoding in humans [J].
Davachi, Lila .
CURRENT OPINION IN NEUROBIOLOGY, 2006, 16 (06) :693-700
[6]
Positive or negative blips? The effect of phase encoding scheme on susceptibility-induced signal losses in EPI [J].
De Panfilis, C ;
Schwarzbauer, C .
NEUROIMAGE, 2005, 25 (01) :112-121
[7]
Optimized EPI for fMRI studies of the orbitofrontal cortex [J].
Deichmann, R ;
Gottfried, JA ;
Hutton, C ;
Turner, R .
NEUROIMAGE, 2003, 19 (02) :430-441
[8]
The medial temporal lobe and recognition memory [J].
Eichenbaum, H. ;
Yonelinas, A. P. ;
Ranganath, C. .
ANNUAL REVIEW OF NEUROSCIENCE, 2007, 30 :123-152
[9]
A dissociation of encoding and retrieval processes in the human hippocampus [J].
Eldridge, LL ;
Engel, SA ;
Zeineh, MM ;
Bookheimer, SY ;
Knowlton, BJ .
JOURNAL OF NEUROSCIENCE, 2005, 25 (13) :3280-3286
[10]
ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139