An embedded barcode for "connected" malaria rapid diagnostic tests

被引:30
作者
Scherr, Thomas F. [1 ]
Gupta, Sparsh [1 ]
Wright, David W. [2 ]
Haselton, Frederick R. [1 ,2 ]
机构
[1] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Dept Chem, Nashville, TN 37235 USA
关键词
LATERAL FLOW ASSAYS; CLINICAL MALARIA; PAPER; CAPTURE; PERFORMANCE; MICROSCOPY; PARASITES; PLATFORM; QUALITY; FIELD;
D O I
10.1039/c6lc01580h
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Many countries are shifting their efforts from malaria control to disease elimination. New technologies will be necessary to meet the more stringent demands of elimination campaigns, including improved quality control of malaria diagnostic tests, as well as an improved means for communicating test results among field healthcare workers, test manufacturers, and national ministries of health. In this report, we describe and evaluate an embedded barcode within standard rapid diagnostic tests as one potential solution. This information-augmented diagnostic test operates on the familiar principles of traditional lateral flow assays and simply replaces the control line with a control grid patterned in the shape of a QR (quick response) code. After the test is processed, the QR code appears on both positive or negative tests. In this report we demonstrate how this multipurpose code can be used not only to fulfill the control line role of test validation, but also to embed test manufacturing details, serve as a trigger for image capture, enable registration for image analysis, and correct for lighting effects. An accompanying mobile phone application automatically captures an image of the test when the QR code is recognized, decodes the QR code, performs image processing to determine the concentration of the malarial biomarker histidine-rich protein 2 at the test line, and transmits the test results and QR code payload to a secure web portal. This approach blends automated, sub-nanomolar biomarker detection, with near real-time reporting to provide quality assurance data that will help to achieve malaria elimination.
引用
收藏
页码:1314 / 1322
页数:9
相关论文
共 38 条
[21]  
Organization W. H., 2008, IN QUAL ASS MAL RAP
[22]  
Organization W. H., 2011, MALARIA RAPID DIAGNO, P124
[23]   Minimising human error in malaria rapid diagnosis: clarity of written instructions and health worker performance [J].
Rennie, Waverly ;
Phetsouvanh, Rattanaxay ;
Lupisan, Socorro ;
Vanisaveth, Viengsay ;
Hongvanthong, Bouasy ;
Phompida, Sarnlane ;
Alday, Portia ;
Fulache, Mila ;
Lumagui, Richard ;
Jorgensen, Pernille ;
Bell, David ;
Harvey, Steven .
TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2007, 101 (01) :9-18
[24]   Overdiagnosis of malaria in patients with severe febrile illness in Tanzania: a prospective study [J].
Reyburn, H ;
Mbatia, R ;
Drakeley, C ;
Carneiro, I ;
Mwakasungula, E ;
Mwerinde, O ;
Saganda, K ;
Shao, J ;
Kitua, A ;
Olomi, R ;
Greenwood, BM ;
Whitty, CJM .
BMJ-BRITISH MEDICAL JOURNAL, 2004, 329 (7476) :1212-1215
[25]   Low cost, simple three dimensional electrochemical paper-based analytical device for determination of p-nitrophenol [J].
Santhiago, Murilo ;
Henry, Charles S. ;
Kubota, Lauro T. .
ELECTROCHIMICA ACTA, 2014, 130 :771-777
[26]   WHAT IS CLINICAL MALARIA - FINDING CASE DEFINITIONS FOR FIELD-RESEARCH IN HIGHLY ENDEMIC AREAS [J].
SCHELLENBERG, JRMA ;
SMITH, T ;
ALONSO, PL ;
HAYES, RJ .
PARASITOLOGY TODAY, 1994, 10 (11) :439-442
[27]   Mobile phone imaging and cloud-based analysis for standardized malaria detection and reporting [J].
Scherr, Thomas F. ;
Gupta, Sparsh ;
Wright, David W. ;
Haselton, Frederick R. .
SCIENTIFIC REPORTS, 2016, 6
[28]   End-user errors in applying two malaria rapid diagnostic tests in a remote area of Sudan [J].
Seidahmed, Osama M. E. ;
Mohamedein, Muneir M. N. ;
Elsir, Afrah A. ;
Ali, Fayez T. ;
Malik, El Fatih M. ;
Ahmed, Eldirdieri S. .
TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2008, 13 (03) :406-409
[29]   IS FEVER A GOOD SIGN FOR CLINICAL MALARIA IN SURVEYS OF ENDEMIC COMMUNITIES [J].
SMITH, T ;
HURT, N ;
TEUSCHER, T ;
TANNER, M .
AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 1995, 52 (04) :306-310
[30]   HIGH-SENSITIVITY OF DETECTION OF HUMAN MALARIA PARASITES BY THE USE OF NESTED POLYMERASE CHAIN-REACTION [J].
SNOUNOU, G ;
VIRIYAKOSOL, S ;
ZHU, XP ;
JARRA, W ;
PINHEIRO, L ;
DOROSARIO, VE ;
THAITHONG, S ;
BROWN, KN .
MOLECULAR AND BIOCHEMICAL PARASITOLOGY, 1993, 61 (02) :315-320