Fluorescent fiber optic calcium sensor for physiological measurements

被引:630
作者
Shortreed, M
Kopelman, R
Kuhn, M
Hoyland, B
机构
[1] UNIV MICHIGAN,DEPT CHEM,ANN ARBOR,MI 48109
[2] MOLEC PROBES INC,EUGENE,OR 97402
关键词
D O I
10.1021/ac950944k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new optical sensor based on covalent immobilization of a newly synthesized calcium-selective, long-wavelength, fluorescent indicator has been constructed, with a response dynamic range optimal for physiological measurements, Immobilization occurs via photoinitiated copolymerization of the indicator with acrylamide on the distal end of a silanized 125 mu m diameter multimode optical fiber. The working lifetime of this sensor is limited only by photobleaching of the indicator. Due to the inherent hydrophilic nature of the acrylamide polymer, the response time of this new sensor is governed by simple aqueous diffusion of the ionic calcium, This results in sensor response times fast enough to monitor some concentration fluctuations at physiological rates. The ability to monitor calcium concentration fluctuations in a high background level of magnesium is also demonstrated with a calculated selectivity of 10(-4.5).
引用
收藏
页码:1414 / 1418
页数:5
相关论文
共 28 条
[1]  
Ammann, 1986, ION SELECTIVE MICROE
[2]  
[Anonymous], FLOW CYTOMETRY PRACT
[3]   AN OPTICAL CALCIUM-ION SENSOR [J].
ASHWORTH, DC ;
HUANG, HP ;
NARAYANASWAMY, R .
ANALYTICA CHIMICA ACTA, 1988, 213 (1-2) :251-257
[4]   FIBER OPTIC SENSOR FOR CA2+ BASED ON AN INDUCED CHANGE IN THE CONFORMATION OF THE PROTEIN CALMODULIN [J].
BLAIR, TL ;
YANG, ST ;
SMITHPALMER, T ;
BACHAS, LG .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :300-302
[5]   OPTICAL SENSOR FOR CALCIUM - PERFORMANCE, STRUCTURE, AND REACTIVITY OF CALCICHROME IMMOBILIZED AT AN ANIONIC POLYMER FILM [J].
CHAU, LK ;
PORTER, MD .
ANALYTICAL CHEMISTRY, 1990, 62 (18) :1964-1971
[6]   A CALCIUM-SELECTIVE OPTRODE BASED ON THE FLUORESCENCE OF DANSYLATED TROPONIN [J].
ECKERTTILOTTA, SE ;
SCOUTEN, WH ;
HINES, J .
APPLIED SPECTROSCOPY, 1991, 45 (03) :491-495
[7]   PREPARATION AND CHARACTERIZATION OF LYOPHILIZED POLYACRYLAMIDE ENZYME GELS FOR CHEMICAL ANALYSIS [J].
HICKS, GP ;
UPDIKE, SJ .
ANALYTICAL CHEMISTRY, 1966, 38 (06) :726-&
[8]  
JUNTER GA, 1988, ELECTROCHEMICAL DETE
[9]   FIBER-OPTIC CALCIUM(II) SENSOR WITH REVERSIBLE RESPONSE [J].
KAWABATA, Y ;
TAHARA, R ;
IMASAKA, T ;
ISHIBASHI, N .
ANALYTICA CHIMICA ACTA, 1988, 212 (1-2) :267-271
[10]   FLUORESCENCE LIFETIME IMAGING OF CALCIUM USING QUIN-2 [J].
LAKOWICZ, JR ;
SZMACINSKI, H ;
NOWACZYK, K ;
JOHNSON, ML .
CELL CALCIUM, 1992, 13 (03) :131-147