Impact of variance components on reliability of absolute quantification using digital PCR

被引:46
作者
Jacobs, Bart K. M. [1 ]
Goetghebeur, Els [1 ]
Clement, Lieven [1 ]
机构
[1] Univ Ghent, Dept Appl Math Comp Sci & Stat, B-9000 Ghent, Belgium
来源
BMC BIOINFORMATICS | 2014年 / 15卷
关键词
Digital PCR; Absolute nucleic acid quantification; CNV; Variance component; Precision; Accuracy; Reliability; Experimental design; Polymerase chain reaction; GUIDELINES MINIMUM INFORMATION; POLYMERASE-CHAIN-REACTION; REAL-TIME PCR; QUANTITATION; DNA; PUBLICATION;
D O I
10.1186/1471-2105-15-283
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Digital polymerase chain reaction (dPCR) is an increasingly popular technology for detecting and quantifying target nucleic acids. Its advertised strength is high precision absolute quantification without needing reference curves. The standard data analytic approach follows a seemingly straightforward theoretical framework but ignores sources of variation in the data generating process. These stem from both technical and biological factors, where we distinguish features that are 1) hard-wired in the equipment, 2) user-dependent and 3) provided by manufacturers but may be adapted by the user. The impact of the corresponding variance components on the accuracy and precision of target concentration estimators presented in the literature is studied through simulation. Results: We reveal how system-specific technical factors influence accuracy as well as precision of concentration estimates. We find that a well-chosen sample dilution level and modifiable settings such as the fluorescence cut-off for target copy detection have a substantial impact on reliability and can be adapted to the sample analysed in ways that matter. User-dependent technical variation, including pipette inaccuracy and specific sources of sample heterogeneity, leads to a steep increase in uncertainty of estimated concentrations. Users can discover this through replicate experiments and derived variance estimation. Finally, the detection performance can be improved by optimizing the fluorescence intensity cut point as suboptimal thresholds reduce the accuracy of concentration estimates considerably. Conclusions: Like any other technology, dPCR is subject to variation induced by natural perturbations, systematic settings as well as user-dependent protocols. Corresponding uncertainty may be controlled with an adapted experimental design. Our findings point to modifiable key sources of uncertainty that form an important starting point for the development of guidelines on dPCR design and data analysis with correct precision bounds. Besides clever choices of sample dilution levels, experiment-specific tuning of machine settings can greatly improve results. Well-chosen data-driven fluorescence intensity thresholds in particular result in major improvements in target presence detection. We call on manufacturers to provide sufficiently detailed output data that allows users to maximize the potential of the method in their setting and obtain high precision and accuracy for their experiments.
引用
收藏
页数:13
相关论文
共 26 条
[1]   Digital PCR hits its stride [J].
Baker, Monya .
NATURE METHODS, 2012, 9 (06) :541-544
[2]   Single molecule detection in nanofluidic digital array enables accurate measurement of DNA copy number [J].
Bhat, Somanath ;
Herrmann, Jan ;
Armishaw, Paul ;
Corbisier, Philippe ;
Emslie, Kerry R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (02) :457-467
[3]   The applicability of digital PCR for the assessment of detection limits in GMO analysis [J].
Burns, M. J. ;
Burrell, A. M. ;
Foy, C. A. .
EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2010, 231 (03) :353-362
[4]   The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments [J].
Bustin, Stephen A. ;
Benes, Vladimir ;
Garson, Jeremy A. ;
Hellemans, Jan ;
Huggett, Jim ;
Kubista, Mikael ;
Mueller, Reinhold ;
Nolan, Tania ;
Pfaffl, Michael W. ;
Shipley, Gregory L. ;
Vandesompele, Jo ;
Wittwer, Carl T. .
CLINICAL CHEMISTRY, 2009, 55 (04) :611-622
[5]   Digital PCR strategies in the development and analysis of molecular biomarkers for personalized medicine [J].
Day, Elizabeth ;
Dear, Paul H. ;
McCaughan, Frank .
METHODS, 2013, 59 (01) :101-107
[6]   THE EVALUATION OF LIMITING DILUTION ASSAYS [J].
DESTGROTH, SF .
JOURNAL OF IMMUNOLOGICAL METHODS, 1982, 49 (02) :R11-R23
[7]   Mathematical Analysis of Copy Number Variation in a DNA Sample Using Digital PCR on a Nanofluidic Device [J].
Dube, Simant ;
Qin, Jian ;
Ramakrishnan, Ramesh .
PLOS ONE, 2008, 3 (08)
[8]   TURBIDITY FLUCTUATIONS IN FLOWING SUSPENSIONS [J].
GREGORY, J .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1985, 105 (02) :357-371
[9]   Comparison of Droplet Digital PCR to Real-Time PCR for Quantitative Detection of Cytomegalovirus [J].
Hayden, R. T. ;
Gu, Z. ;
Ingersoll, J. ;
Abdul-Ali, D. ;
Shi, L. ;
Pounds, S. ;
Caliendo, A. M. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (02) :540-546
[10]   Low-level detection and quantitation of cellular HIV-1 DNA and 2-LTR circles using droplet digital PCR [J].
Henrich, Timothy J. ;
Gallien, Sebastien ;
Li, Jonathan Z. ;
Pereyra, Florencia ;
Kuritzkes, Daniel R. .
JOURNAL OF VIROLOGICAL METHODS, 2012, 186 (1-2) :68-72