Assessment of errors in static electrical impedance tomography with adjacent and trigonometric current patterns

被引:111
作者
Kolehmainen, V
Vauhkonen, M
Karjalainen, PA
Kaipio, JP
机构
[1] UNIV KUOPIO,DEPT APPL PHYS,FIN-70211 KUOPIO,FINLAND
[2] UNIV OULU,DEPT MATH SCI,FIN-90570 OULU,FINLAND
关键词
static EIT; errors in EIT; complete electrode model; current patterns; regularization;
D O I
10.1088/0967-3334/18/4/003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In electrical impedance tomography (EIT), difference imaging is often preferred over static imaging. This is because of the many unknowns in the forward modelling which make it difficult to obtain reliable absolute resistivity estimates. However, static imaging and absolute resistivity values are needed in some potential applications of EIT. In this paper we demonstrate by simulation the effects of different error components that are included in the reconstruction of static EIT images. All simulations are carried out in two dimensions with the so-called complete electrode model. Errors that are considered are the modelling error in the boundary shape of an object, errors in the electrode sizes and localizations and errors in the contact impedances under the electrodes. Results using both adjacent and trigonometric current patterns are given.
引用
收藏
页码:289 / 303
页数:15
相关论文
共 30 条
  • [1] Errors in reconstruction of resistivity images using a linear reconstruction technique
    Barber, D.C.
    Brown, B.H.
    [J]. Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A): : 101 - 104
  • [2] Effect of skin impedance on image quality and variability in electrical impedance tomography: A model study
    Boone, KG
    Holder, DS
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (05) : 351 - 354
  • [3] Data errors and reconstruction algorithms in electrical impedance tomography
    Breckon, W.R.
    Pidcock, M.K.
    [J]. Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A): : 105 - 109
  • [4] Possibilities and problems of real-time imaging of tissue resistivity
    Brown, B.H.
    Barber, D.C.
    [J]. Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A): : 121 - 125
  • [5] APPLIED POTENTIAL TOMOGRAPHY - POSSIBLE CLINICAL-APPLICATIONS
    BROWN, BH
    BARBER, DC
    SEAGAR, AD
    [J]. CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1985, 6 (02): : 109 - 121
  • [6] ELECTRODE MODELS FOR ELECTRIC-CURRENT COMPUTED-TOMOGRAPHY
    CHENG, KS
    ISAACSON, D
    NEWELL, JC
    GISSER, DG
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (09) : 918 - 924
  • [7] ERRORS DUE TO MEASURING VOLTAGE ON CURRENT-CARRYING ELECTRODES IN ELECTRIC-CURRENT COMPUTED-TOMOGRAPHY
    CHENG, KS
    SIMSKE, SJ
    ISAACSON, D
    NEWELL, JC
    GISSER, DG
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) : 60 - 65
  • [8] RESOLUTION AND STABILITY ANALYSIS OF AN INVERSE PROBLEM IN ELECTRICAL-IMPEDANCE TOMOGRAPHY - DEPENDENCE ON THE INPUT CURRENT PATTERNS
    DOBSON, DC
    SANTOSA, F
    [J]. SIAM JOURNAL ON APPLIED MATHEMATICS, 1994, 54 (06) : 1542 - 1560
  • [9] COMMENTS ON DISTINGUISHABILITY IN ELECTRICAL-IMPEDANCE IMAGING
    EYUBOGLU, BM
    PILKINGTON, TC
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (12) : 1328 - 1330
  • [10] Influence of changing peripheral geometry on electrical impedance tomography measurements
    Gersing, E
    Hofmann, B
    Osypka, M
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (05) : 359 - 361