Destruction of contrast microbubbles during ultrasound imaging at conventional power output

被引:37
作者
Villarraga, HR
Foley, DA
Aeschbacher, BC
Klarich, KW
Mulvagh, SL
机构
[1] MAYO CLIN & MAYO FDN,DIV CARDIOVASC DIS,ROCHESTER,MN 55905
[2] MAYO CLIN & MAYO FDN,DIV CARDIOVASC DIS & INTERNAL MED,ROCHESTER,MN 55905
[3] UNIV HOSP BERN,INSELSPITAL,CH-3010 BERN,SWITZERLAND
关键词
D O I
10.1016/S0894-7317(97)70036-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Inhomogeneous opacification of cardiac chambers has been frequently observed after intravenous administration of long-persisting echocardiographic contrast agents. We observed this phenomenon to be most pronounced at high acoustic powers with incomplete opacification of the left ventricular apex and left ventricular outflow tract. Reducing the acoustic energy to which the contrast was exposed by decreasing transmit power or intermittently suspending insonification resulted in homogenous opacification of the entire left ventricular cavity. We systematically examined the effect of varying insonification power on the persistence of three investigational ultrasound contrast agents in both in vitro and in vivo models. We found an inverse relationship between the insonifying power and the persistence of the contrast agents. Contrast intensity decay could be reduced either by decreasing exposure to ultrasound by minimizing the transmit power of the system or by intermittently suspending ultrasound generation (triggering). Minimization of ultrasound contrast exposure to ultrasound energy thus improves echocardiographic contrast duration and homogeneity.
引用
收藏
页码:783 / 791
页数:9
相关论文
共 14 条
[1]   PRINCIPLES AND RECENT DEVELOPMENTS IN ULTRASOUND CONTRAST AGENTS [J].
DEJONG, N ;
TENCATE, FJ ;
LANCEE, CT ;
ROELANDT, JRTC ;
BOM, N .
ULTRASONICS, 1991, 29 (04) :324-330
[3]  
GOTTLIEB S, 1995, J ULTRAS MED, V14, P109
[4]   EFFECTS OF LEFT-VENTRICULAR PRESSURE ON SONICATED ALBUMIN MICROBUBBLES - EVALUATION USING AN ISOLATED RABBIT HEART MODEL [J].
MORAVI, V ;
SHROFF, SG ;
ROBINSON, KA ;
NG, AF ;
CHOLLEY, BP ;
MARCUS, RH ;
LANG, RM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (07) :1779-1785
[5]  
OBrien Jr W.D., 1986, Echocardiography, V3, P165
[6]   TRANSIENT MYOCARDIAL CONTRAST AFTER INITIAL EXPOSURE TO DIAGNOSTIC ULTRASOUND PRESSURES WITH MINUTE DOSES OF INTRAVENOUSLY INJECTED MICROBUBBLES - DEMONSTRATION AND POTENTIAL MECHANISMS [J].
PORTER, TR ;
XIE, F .
CIRCULATION, 1995, 92 (09) :2391-2395
[7]  
SCHOLLE FD, 1994, 1994 IEEE ULTR S P, V3, P1563
[8]   Osmotically stabilized microbubble sonographic contrast agents [J].
Schutt, EG ;
Pelura, TJ ;
Hopkins, RM .
ACADEMIC RADIOLOGY, 1996, 3 :S188-S190
[9]   INTRAVENOUS CONTRAST ECHOCARDIOGRAPHY WITH USE OF SONICATED ALBUMIN IN HUMANS - SYSTOLIC DISAPPEARANCE OF LEFT-VENTRICULAR CONTRAST AFTER TRANSPULMONARY TRANSMISSION [J].
SHAPIRO, JR ;
REISNER, SA ;
LICHTENBERG, GS ;
MELTZER, RS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (07) :1603-1607
[10]  
UHLENDORF V, 1994, 1994 IEEE ULTR S P, V3, P1559