A rapid and reliable method for the quantitation of tricyclic antidepressants in serum using HPLC-MS/MS

被引:44
作者
Breaud, Autumn R. [1 ]
Harlan, Robert [1 ]
Kozak, Marta [1 ]
Clarke, William [1 ]
机构
[1] Johns Hopkins Univ, Dept Pathol, Baltimore, MD USA
关键词
HPLC-MS/MS; Amitriptyline; Nortriptyline; Imipramine; Desipramine; Therapeutic drug monitoring; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; HUMAN-PLASMA; ELECTROSPRAY-IONIZATION; GAS-CHROMATOGRAPHY; SAMPLE PREPARATION; ISOTOPE-DILUTION; ION SUPPRESSION; DRUGS; MATRIX;
D O I
10.1016/j.clinbiochem.2009.05.006
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
100118 [医学信息学]; 100208 [临床检验诊断学];
摘要
Objective: Here we describe a liquid chromatography-tandem mass spectrometry method for the detection of tricyclic antidepressant drugs (amitriptyline, desipramme, imipramine, and nortriptyline) in serum. Design and methods: Following a protein precipitation from serum and dilution of supernatant with water, these analytes and their internal standards (deuterated versions of each drug) were injected, separated, and eluted from a Hypersil Gold C-18 (50 x 2.1 mm) analytical column with a gradient of water and acetonitrile each with 0.1% formic acid. Analytes were then ionized and detected over a 3.5 minute analysis time by electrospray ionization mass spectrometry with multiple reaction monitoring. Matrix effects were characterized using three methods: post-column infusion, pre- and post-extraction addition of analyte to matrix, and comparison of neet to serum preparations. Results: The inter-day and intra-day coefficients of variation for all compounds were <= 12%. The limit of detection for all drugs was < 15 ng/mL and the limit quantitation for all drugs was <22 ng/mL. Recoveries were between 97 and 131% for all drugs. Patient method comparison and proficiency samples were run with acceptable results. Conclusion: We have developed a specific and sensitive method for rapid quantitation of tricyclic antidepressants in serum, suitable for use in the clinical laboratory. (C) 2009 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1300 / 1307
页数:8
相关论文
共 34 条
[1]
Analysis of tricyclic antidepressant drugs in plasma by means of solid-phase microextraction-liquid chromatography-mass spectrometry [J].
Alves, Claudete ;
Santos-Neto, Alvaro J. ;
Fernandes, Christian ;
Rodrigues, Jose C. ;
Lancas, Fernando M. .
JOURNAL OF MASS SPECTROMETRY, 2007, 42 (10) :1342-1347
[2]
Ion suppression in mass spectrometry [J].
Annesley, TM .
CLINICAL CHEMISTRY, 2003, 49 (07) :1041-1044
[3]
Sensitive and rapid method for the simultaneous quantification of five antidepressants with their respective metabolites in plasma using high-performance liquid chromatography with diode-array detection [J].
Aymard, G ;
Livi, P ;
Pham, YT ;
Diquet, B .
JOURNAL OF CHROMATOGRAPHY B, 1997, 700 (1-2) :183-189
[4]
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.0.CO
[5]
2-0
[6]
Bose Devasish, 2005, Journal of Pharmacological and Toxicological Methods, V52, P323, DOI 10.1016/j.vascn.2005.04.015
[7]
Matrix effect in bio-analysis of illicit drugs with LC-MS/MS: Influence of ionization type, sample preparation, and biofluid [J].
Dams, R ;
Huestis, MA ;
Lambert, WE ;
Murphy, CM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (11) :1290-1294
[8]
SENSITIVE AND QUANTITATIVE-DETERMINATION OF PLASMA DOXEPIN AND DESMETHYLDOXEPIN IN CHRONIC PAIN PATIENTS BY GAS-CHROMATOGRAPHY AND MASS-SPECTROMETRY [J].
DAVIS, TP ;
VEGGEBERG, SK ;
HAMEROFF, SR ;
WATTS, KL .
JOURNAL OF CHROMATOGRAPHY, 1983, 273 (02) :436-441
[9]
Effect of the sample matrix on the determination of indinavir in human urine by HPLC with turbo ion spray tandem mass spectrometric detection [J].
Fu, I ;
Woolf, EJ ;
Matuszewski, BK .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (03) :347-357
[10]
GARLAND WA, 1979, CLIN PHARMACOL THER, V25, P844