Feasibility of using orthogonal fluoroscopic images to measure in vivo joint kinematics

被引:156
作者
Li, GA
Wuerz, TH
DeFrate, LE
机构
[1] Massachusetts Gen Hosp, Dept Orthopaed Surg, Bioengn Lab, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
[3] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2004年 / 126卷 / 02期
关键词
D O I
10.1115/1.1691448
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Accurately determining in vivo knee kinematics is still a challenge in biomedical engineering. This paper presents an imaging technique using two orthogonal images to measure 6 degree-of-freedom (DOF) knee kinematics during weight-bearing flexion. Using this technique, orthogonal images of the knee were captured using a 3-D fluoroscope at different flexion angles during weight-bearing flexion. The two orthogonal images uniquely characterized the knee Position at the specific flexion angle. A virtual fluoroscope was then created in solid modeling software and was used to reproduce the relative positions of the orthogonal images and X-ray sources of the 3-D fluoroscope during the actual imaging procedure. Two virtual cameras in the software were used to represent the X-ray sources. The 3-D computer model of the knee was then introduced into the virtual fluoroscope and was projected onto the orthogonal images by the two virtual cameras. By matching the projections of the knee model to the orthogonal images of the knee obtained during weight-bearing flexion, the knee kinematics in 6 DOF were determined. Using regularly shaped objects with known positions and orientations, this technique was shown to have an accuracy, of 0.1 mm and 0.1 deg in determining the positions and orientations of the objects, respectively.
引用
收藏
页码:314 / 318
页数:5
相关论文
共 17 条
[1]  
Andrade F, 1998, MECH ENG, V120, P6
[2]   FUNCTIONAL-ANALYSIS OF PRE-KNEE AND POST-KNEE SURGERY - TOTAL KNEE ARTHROPLASTY AND ACL RECONSTRUCTION [J].
ANDRIACCHI, TP .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :575-581
[3]   In vivo three-dimensional knee kinematics using a biplanar image-matching technique [J].
Asano, T ;
Akagi, M ;
Tanaka, K ;
Tamura, J ;
Nakamura, T .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (388) :157-166
[4]   Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[5]   MEASUREMENT ERRORS IN ROENTGEN-STEREOPHOTOGRAMMETRIC JOINT-MOTION ANALYSIS [J].
DELANGE, A ;
HUISKES, R ;
KAUER, JMG .
JOURNAL OF BIOMECHANICS, 1990, 23 (03) :259-269
[6]  
DENNIS DA, 1996, CLIN ORTHOP RELAT R, V331, P107
[7]   The movement of the knee studied by magnetic resonance imaging [J].
Freeman, MAR ;
Pinskerova, V .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :35-43
[8]   Three-dimensional tibiofemoral kinematics of the anterior cruciate ligament-deficient and reconstructed knee during walking [J].
Georgoulis, AD ;
Papadonikolakis, A ;
Papageorgiou, CD ;
Mitsou, A ;
Stergiou, N .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (01) :75-79
[9]   CHRONIC ANTEROLATERAL INSTABILITY OF THE KNEE - A ROENTGEN STEREOPHOTOGRAMMETRIC EVALUATION [J].
KARRHOLM, J ;
ELMQVIST, LG ;
SELVIK, G ;
HANSSON, LI .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (04) :555-563
[10]   In vivo fluoroscopic analysis of the normal human knee [J].
Komistek, RD ;
Dennis, DA ;
Mahfouz, M .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :69-81