Double hepatic arterial phase MRI of the liver with switching of reversed centric and centric k-space reordering

被引:14
作者
Kanematsu, Masayuki
Goshima, Satoshi
Kondo, Hiroshi
Yokoyama, Ryujiro
Kajita, Kimihiro
Hoshi, Hiroaki
Onozuka, Minoru
Nozaki, Atsushi
Hirano, Masaya
Shiratori, Yoshimune
Moriyama, Noriyuki
机构
[1] Gifu Univ Hosp, Dept Radiol Serv, Gifu 5011193, Japan
[2] Gifu Univ, Sch Med, Dept Radiol, Gifu 500, Japan
[3] Kanagawa Dent Coll, Dept Physiol & Neurosci, Yokosuka, Kanagawa 238, Japan
[4] GE Yokogawa Med Syst, Imaging Applicat Technol Ctr, Tokyo, Japan
[5] Gifu Univ, Sch Med, Dept Med Informat, Gifu 500, Japan
[6] Natl Canc Ctr Hosp, Res Ctr Canc Prevent & Screening, Tsukiji, Japan
关键词
contrast media; high resolution; k-space reordering; liver; MR technique;
D O I
10.2214/AJR.05.0522
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
OBJECTIVE. The purpose of our study was to evaluate the clinical feasibility and usefulness of a 2D spoiled gradient-recalled echo MR sequence with serial switching of reversed centric and centric k-space reordering for high-spatial-resolution gadolinium-enhanced double hepatic arterial phase (HAP) MRI of the liver. SUBJECTS AND METHODS. MR images (frequency, 512; phase encoding without interpolation, 224; 6-mm thickness with 1-mm gap; 30 slices per 18 seconds) were obtained with multiphase imaging in which central k-space line data were filled 10, 21, 49, and 181 seconds after arrival of contrast medium in the abdominal aorta for the early HAP (reversed centric reordering, center of k-space lines acquired at end of acquisition), late HAP (centric reordering, center of k-space lines at beginning of acquisition), portal venous phase (centric reordering), and equilibrium phase (centric reordering), respectively, in 102 consecutive patients with suspected liver disease, including 48 untreated hepatocellular carcinomas (HCCs) in 35 patients. Images were quantitatively assessed for degree of contrast enhancement in the abdominal aorta, spleen, portal trunk, liver parenchyma, hepatic veins, and HCCs. Images were qualitatively assessed for the effectiveness of contrast enhancement in each phase and for degree of image degradation due to artifacts. RESULTS. Enhancement of the abdominal aorta peaked in the early HAP, of the portal trunk in the late HAP, and of the hepatic parenchyma and veins in the portal venous phase. Mean HCC-to-liver contrast peaked in the early HAP and turned to a negative value in the portal venous and equilibrium phases. Sufficient image quality was achieved in 99 (97%) of the patients. One of the other three patients had motion artifacts due to body motion, and the other two had unsatisfactory respiratory suspension. Scan timing for early and late HAP was optimal in 74 (73%) of the patients, for late HAP lagged in 20 (20%), for early HAP was premature in six (6%), and for early HAP lagged in five (5%) of the patients. CONCLUSION. We confirmed the feasibility and usefulness of a 2D gadolinium-enhanced double HAP spoiled gradient-recalled echo sequence incorporating serial switching of reversed centric and centric k-space reordering. This method has the potential for use in high-spatial-resolution double HAP MRI for the diagnosis of hypervascular HCC.
引用
收藏
页码:464 / 472
页数:9
相关论文
共 12 条
[1]
IMAGING TIME REDUCTION THROUGH MULTIPLE RECEIVER COIL DATA ACQUISITION AND IMAGE-RECONSTRUCTION [J].
CARLSON, JW ;
MINEMURA, T .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (05) :681-688
[2]
AN ALGORITHM FOR NMR IMAGING RECONSTRUCTION BASED ON MULTIPLE RF RECEIVER COILS [J].
CARLSON, JW .
JOURNAL OF MAGNETIC RESONANCE, 1987, 74 (02) :376-380
[3]
Can a multiphasic contrast-enhanced three-dimensional fast spoiled gradient-recalled echo sequence be sufficient for liver MR imaging? [J].
Coulam, CH ;
Chan, FP ;
Li, KCP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (02) :335-341
[4]
FLEISS JL, 1986, ANAL VARIANCE MULTIP, P51
[5]
A brief review of parallel magnetic resonance imaging [J].
Heidemann, RM ;
Özsarlak, Ö ;
Parizel, PM ;
Michiels, J ;
Kiefer, B ;
Jellus, V ;
Müller, M ;
Breuer, F ;
Blaimer, M ;
Griswold, MA ;
Jakob, PM .
EUROPEAN RADIOLOGY, 2003, 13 (10) :2323-2337
[6]
The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality [J].
Maki, JH ;
Prince, MR ;
Londy, FJ ;
Chenevert, TL .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04) :642-651
[7]
Hypervascular hepatocellular carcinoma: Detection with double arterial phase multi-detector row helical CT [J].
Murakami, T ;
Kim, T ;
Takamura, M ;
Hori, M ;
Takahashi, S ;
Federle, MP ;
Tsuda, K ;
Osuga, K ;
Kawata, S ;
Nakamura, H ;
Kudo, M .
RADIOLOGY, 2001, 218 (03) :763-767
[8]
3D time-of-flight MR angiography of the intracranial vessels:: optimization of the technique with water excitation, parallel acquisition, eight-channel phased-array head coil and low-dose contrast administration [J].
Özsarlak, Ö ;
Van Goethem, JW ;
Parizel, PM .
EUROPEAN RADIOLOGY, 2004, 14 (11) :2067-2071
[9]
A 16-element phased-array head coil [J].
Porter, JR ;
Wright, SM ;
Reykowski, A .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (02) :272-279
[10]
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays [J].
Sodickson, DK ;
Manning, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) :591-603