Chemical cytometry on a picoliter-scale integrated microfluidic chip

被引:208
作者
Wu, HK [1 ]
Wheeler, A [1 ]
Zare, RN [1 ]
机构
[1] Stanford Univ, Dept Chem, Stanford, CA 94305 USA
关键词
D O I
10.1073/pnas.0405299101
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
An integrated microfluidic device has been fabricated for analyzing the chemical contents of a single cell (chemical cytometry). The device is designed to accomplish four different functions: (i) cell handling, (it) metering and delivering of chemical reagents, (iii) cell lysis and chemical derivatization, and (iv) separating derivatized compounds and detecting them by laser-induced fluorescence. These functions are accomplished with only two valves, formed by multilayer soft lithography. A new kind of three-state valve and a picopipette are described; these elements are crucial for minimizing the reaction volume and ensuring optimal shape of the channel for electrophoresis injection. By using these valves, a reaction volume of approximate to70 pl is achieved for the lysis and derivitization of the contents of a single Jurkat T cell (approximate to10 mum diameter). As a demonstration of the use of this integrated microfluidic device, electropherograms of amino acids from individual Jurkat T cells are recorded and compared with those collected from a multiple-cell homogenate.
引用
收藏
页码:12809 / 12813
页数:5
相关论文
共 31 条
[1]   Fabrication of topologically complex three-dimensional microfluidic systems in PDMS by rapid prototyping [J].
Anderson, JR ;
Chiu, DT ;
Jackman, RJ ;
Cherniavskaya, O ;
McDonald, JC ;
Wu, HK ;
Whitesides, SH ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3158-3164
[2]   Probing single secretory vesicles with capillary electrophoresis [J].
Chiu, DT ;
Lillard, SJ ;
Scheller, RH ;
Zare, RN ;
Rodriguez-Cruz, SE ;
Williams, ER ;
Orwar, O ;
Sandberg, M ;
Lundqvist, JA .
SCIENCE, 1998, 279 (5354) :1190-1193
[3]   A Microfabricated Rotary Pump [J].
Chou, Hou-Pu ;
Unger, Marc A. ;
Quake, Stephen R. .
BIOMEDICAL MICRODEVICES, 2001, 3 (04) :323-330
[4]   Microchip injection and separation anomalies due to pressure effects [J].
Crabtree, HJ ;
Cheong, ECS ;
Tilroe, DA ;
Backhouse, CJ .
ANALYTICAL CHEMISTRY, 2001, 73 (17) :4079-4086
[5]   Chemical cytometry [J].
Dovichi, NJ ;
Hu, S .
CURRENT OPINION IN CHEMICAL BIOLOGY, 2003, 7 (05) :603-608
[6]   An integrated microfabricated cell sorter [J].
Fu, AY ;
Chou, HP ;
Spence, C ;
Arnold, FH ;
Quake, SR .
ANALYTICAL CHEMISTRY, 2002, 74 (11) :2451-2457
[7]   Integration of single cell injection, cell lysis, separation and detection of intracellular constituents on a microfluidic chip [J].
Gao, J ;
Yin, XF ;
Fang, ZL .
LAB ON A CHIP, 2004, 4 (01) :47-52
[8]   ANALYSIS OF SINGLE CELLS BY CAPILLARY ELECTROPHORESIS WITH ON COLUMN DERIVATIZATION AND LASER-INDUCED FLUORESCENCE DETECTION [J].
GILMAN, SD ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1995, 67 (01) :58-64
[9]   A robust and scalable microfluidic metering method that allows protein crystal growth by free interface diffusion [J].
Hansen, CL ;
Skordalakes, E ;
Berger, JM ;
Quake, SR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (26) :16531-16536
[10]  
Haugland R.P., 2002, Handbook of Fluorescent Probes and Research Products, V9th