Very low dose mammography: new perspectives in Diffraction Enhanced Imaging (DEI) mammography

被引:16
作者
Bravin, A [1 ]
Fiedler, S [1 ]
Thomlinson, WC [1 ]
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
来源
MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING | 2002年 / 4682卷
关键词
low dose; mammography; synchrotron radiation; DEI; X-ray refraction; ACR; phase contrast; digital detector; imaging; high energy;
D O I
10.1117/12.465555
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Diffraction Enhanced Imaging (DEI) can significantly improve the expressiveness of mammography radiographs. Whereas the contrast in conventional radiographs is based on small X-ray absorption differences of tissues, the contrast mechanism of DEI is, in addition, partially related to the differences in X-ray refraction properties. DEI has been successfully applied to in-vitro mammography studies where little absorption tissue differentiation is present. In this paper we will present work on high-energy DEI mammography, which has been carried out by utilizing a tunable monochromatic X-ray beam. Since the refraction characteristics of soft tissues are much less energy dependent than absorption, the use of high energy X-rays is favoured. They can be employed in mammographic imaging without reducing the image contrast, while getting the benefit of reduced dose since the X-ray absorption falls off considerably. In-vitro images of an American College of Radiology (ACR) mammographic phantom using monochromatic X-rays through 50 keV have been obtained with a digital detector. High-energy mammography has been successfully performed at a significantly lower dose than that usually applied in clinical mammography without important contrast loss.
引用
收藏
页码:167 / 173
页数:5
相关论文
共 25 条
[1]   Low-dose phase contrast x-ray medical imaging [J].
Arfelli, F ;
Assante, M ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Tromba, G ;
Vacchi, A ;
Vallazza, E ;
Zanconati, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :2845-2852
[2]   Mammography with synchrotron radiation: Phase-detection techniques [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Fabrizioli, M ;
Longo, R ;
Menk, RH ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Ratti, M ;
Rigon, L ;
Tromba, G ;
Vacchi, A ;
Vallazza, E ;
Zanconati, F .
RADIOLOGY, 2000, 215 (01) :286-293
[3]   Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment [J].
Boone, JM .
RADIOLOGY, 1999, 213 (01) :23-37
[4]   MAMMOGRAPHY WITH SYNCHROTRON-RADIATION [J].
BURATTINI, E ;
COSSU, E ;
DIMAGGIO, C ;
GAMBACCINI, M ;
INDOVINA, PL ;
MARZIANI, M ;
POCEK, M ;
SIMEONI, S ;
SIMONETTI, G .
RADIOLOGY, 1995, 195 (01) :239-244
[5]   Diffraction enhanced x-ray imaging [J].
Chapman, D ;
Thomlinson, W ;
Johnston, RE ;
Washburn, D ;
Pisano, E ;
Gmur, N ;
Zhong, Z ;
Menk, R ;
Arfelli, F ;
Sayers, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2015-2025
[6]   First human transvenous coronary angiography at the European Synchrotron Radiation Facility [J].
Elleaume, H ;
Fiedler, S ;
Estève, F ;
Bertrand, B ;
Charvet, AM ;
Berkvens, P ;
Berruyer, G ;
Brochard, T ;
Le Duc, G ;
Nemoz, C ;
Renier, M ;
Suortti, P ;
Thomlinson, W ;
Le Bas, JF .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09) :L39-L43
[7]   Instrumentation of the ESRF medical imaging facility [J].
Elleaume, H ;
Charvet, AM ;
Berkvens, P ;
Berruyer, G ;
Brochard, T ;
Dabin, Y ;
Dominguez, MC ;
Draperi, A ;
Fiedler, S ;
Goujon, G ;
Le Duc, G ;
Mattenet, M ;
Nemoz, C ;
Perez, M ;
Renier, M ;
Schulze, C ;
Spanne, P ;
Suortti, P ;
Thomlinson, W ;
Esteve, F ;
Bertrand, B ;
Le Bas, JF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3) :513-527
[8]  
FEIG SA, 1997, MONOGR NATL CANC I, V22, P119
[9]  
FIEDLER A, UNPUB ASSESSMENT SYN
[10]   Dual-energy coronary angiography in pigs using a Gd contrast agent [J].
Fiedler, S ;
Elleaume, H ;
Le Duc, G ;
Nemoz, C ;
Brochard, T ;
Renier, M ;
Bertrand, B ;
Estève, F ;
Le Bas, JF ;
Suortti, P ;
Thomlinson, W .
MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 :96-103