Relative values of the interventions of diversion and improved donor-arm disinfection to reduce the bacterial risk from blood transfusion

被引:84
作者
McDonald, CP
Roy, A
Mahajan, P
Smith, R
Charlett, A
Barbara, JAJ
机构
[1] Natl Blood Serv, Natl Bacteriol Lab, London NW9 5BG, England
[2] Hlth Protect Agcy, London, England
关键词
diversion; disinfection; bacteria;
D O I
10.1111/j.0042-9007.2004.00404.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives The aim of this study was to demonstrate the efficiency of diverting the initial 20-ml donation from the collection bag and of an improved donor-arm disinfection procedure in reducing bacterial contamination in blood. Materials and Methods Donations were collected in bags specially manufactured for the study. These bags incorporated two satellite pouches into each of which 20 ml of blood was collected. Blood initially flowed into sample pouch P1, representing a diversion pouch. Pouch P2 was then filled with 20 ml of blood, which allowed us to sample the collection bag after diversion was complete. Blood then flowed into the standard collection bag. The contents of the pouches were aerobically and anaerobically cultured on the BacT/ALERT automated culture system for 7 days. Two procedures were investigated in the study (each involving 1409 blood donations): one analysed the current disinfection procedure; and the other analysed an improved donor-arm disinfection procedure. Results The use of diversion alone resulted in a 47% reduction in contamination, and improved donor-arm disinfection alone resulted in a 57% reduction in contamination. Diversion plus improved donor-arm disinfection produced a predicted 77% reduction in contamination. Conclusions The study validates diversion and an improved donor-arm disinfection procedure. In combination, these two interventions produced a substantial reduction in contamination. These procedures are to be introduced by the English National Blood Service to enhance the safety of the blood supply.
引用
收藏
页码:178 / 182
页数:5
相关论文
共 14 条
[1]   Evaluation of an automated culture system for detecting bacterial contamination of platelets: an analysis with 15 contaminating organisms [J].
Brecher, ME ;
Means, N ;
Jere, CS ;
Heath, D ;
Rothenberg, S ;
Stutzman, LC .
TRANSFUSION, 2001, 41 (04) :477-482
[2]   Efficacy of a new collection procedure for preventing bacterial contamination of whole-blood donations [J].
Bruneau, C ;
Perez, P ;
Chassaigne, M ;
Allouch, P ;
Audurier, A ;
Gulian, C ;
Janus, G ;
Boulard, G ;
De Micco, P ;
Salmi, LR ;
Noel, L .
TRANSFUSION, 2001, 41 (01) :74-81
[3]   Reduction of bacterial load by predonation sampling [J].
Chassaigne, M ;
Vassort-Bruneau, C ;
Allouch, P ;
Audurier, A ;
Boulard, G ;
Grosdhomme, F ;
Noel, L ;
Gulian, C ;
Janus, G ;
Perez, P .
TRANSFUSION AND APHERESIS SCIENCE, 2001, 24 (03) :253-253
[4]   Diversion of first blood volume results in a reduction of bacterial contamination for whole-blood collections [J].
de Korte, D ;
Marcelis, JH ;
Verhoeven, AJ ;
Soeterboek, AM .
VOX SANGUINIS, 2002, 83 (01) :13-16
[5]  
Figueroa P. I., 1995, Transfusion (Bethesda), V35, p11S
[6]   Evaluation of donor skin disinfection methods [J].
Goldman, M ;
Roy, G ;
Frechette, N ;
Decary, F ;
Massicotte, L ;
Delage, G .
TRANSFUSION, 1997, 37 (03) :309-312
[7]  
McDonald C. P., 2002, CLIN MICROBIOL INFEC, V8, P152
[8]   Evaluation of the 3D BacT/ALERT automated culture system for the detection of microbial contamination of platelet concentrates [J].
McDonald, CP ;
Rogers, A ;
Cox, M ;
Smith, R ;
Roy, A ;
Robbins, S ;
Hartley, S ;
Barbara, JAJ ;
Rothenberg, S ;
Stutzman, L ;
Widders, G .
TRANSFUSION MEDICINE, 2002, 12 (05) :303-309
[9]   Evaluation of donor arm disinfection techniques [J].
McDonald, CP ;
Lowe, P ;
Roy, A ;
Robbins, S ;
Hartley, S ;
Harrison, JF ;
Slopecki, A ;
Verlander, N ;
Barbara, JAJ .
VOX SANGUINIS, 2001, 80 (03) :135-141
[10]  
McDonald CP, 1998, TRANSFUSION MED, V8, P19