A Wireless and Batteryless 10-Bit Implantable Blood Pressure Sensing Microsystem With Adaptive RF Powering for Real-Time Laboratory Mice Monitoring

被引:148
作者
Cong, Peng [1 ]
Chaimanonart, Nattapon [1 ]
Ko, Wen H. [1 ]
Young, Darrin J. [1 ]
机构
[1] Case Western Reserve Univ, Dept Elect Engn & Comp Sci, Cleveland, OH 44106 USA
关键词
Adaptive powering; batteryless implant; blood pressure sensor; biomedical implant; implantable microsystem; low power design; RF powering; wireless implant; NOISE; DESIGN; CIRCUIT;
D O I
10.1109/JSSC.2009.2035551
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An implantable real-time blood pressure monitoring microsystem for laboratory mice has been demonstrated. The system achieves a 10-bit blood pressure sensing resolution and can wirelessly transmit the pressure information to an external unit. The implantable device is operated in a batteryless manner, powered by an external RF power source. The received RF power level can be sensed and wirelessly transmitted along with blood pressure signal for feedback control of the external RF power. The microsystem employs an instrumented silicone cuff, wrapped around a blood vessel with a diameter of approximately 200 mu m, for blood pressure monitoring. The cuff is filled by low-viscosity silicone oil with an immersed MEMS capacitive pressure sensor and integrated electronic system to detect a down-scaled vessel blood pressure waveform with a scaling factor of approximately 0.1. The integrated electronic system, consisting of a capacitance-to-voltage converter, an 11-bit ADC, an adaptive RF powering system, an oscillator-based 433 MHz FSK transmitter and digital control circuitry, is fabricated in a 1.5 mu m CMOS process and dissipates a power of 300 mu W. The packaged microsystem weighs 130 milligram and achieves a capacitive sensing resolution of 75 aF over 1 kHz bandwidth, equivalent to a pressure sensing resolution of 1 mmHg inside an animal vessel, with a dynamic range of 60 dB. Untethered laboratory animal in vivo evaluation demonstrates that the microsystem can capture real-time blood pressure information with a high fidelity under an adaptive RF powering and wireless data telemetry condition.
引用
收藏
页码:3631 / 3644
页数:14
相关论文
共 25 条
[1]   A NEW METHOD FOR CONTINUOUS CHRONIC MEASUREMENT AND RECORDING OF BLOOD-PRESSURE, HEART-RATE AND ACTIVITY IN THE RAT VIA RADIOTELEMETRY [J].
BROCKWAY, BP ;
MILLS, PA ;
AZAR, SH .
CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1991, 13 (05) :885-895
[2]  
Broten T., 1997, Measurement of cardiovascular function
[3]  
CHAIMANONART N, 2009, 6 INT C NETW SENS SY, P52
[4]  
CHAIMANONART N, 2008, P 7 IEEE C SENS OCT, P1421
[5]  
CONG P, 2006, P 28 ANN INT C IEEE, P1854
[6]  
CONG P, 2009, THESIS CASE W RESERV
[7]  
Cong P, 2008, SENSOR MATER, V20, P327
[8]  
Cong P, 2008, IEEE CUST INTEGR CIR, P523, DOI 10.1109/CICC.2008.4672137
[9]   Circuit techniques for reducing the effects of op-amp imperfections: Autozeroing, correlated double sampling, and chopper stabilization [J].
Enz, CC ;
Temes, GC .
PROCEEDINGS OF THE IEEE, 1996, 84 (11) :1584-1614
[10]   A CMOS 13-B CYCLIC RSD A/D CONVERTER [J].
GINETTI, B ;
JESPERS, PGA ;
VANDEMEULEBROECKE, A .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1992, 27 (07) :957-965