Contrast media research

被引:17
作者
Runge, VM [1 ]
机构
[1] Univ Kentucky, Dept Diagnost Radiol, Lexington, KY USA
关键词
D O I
10.1097/00004424-199912000-00009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This selective review highlights research in contrast media development and application in the held of diagnostic radiology in 1998 and 1999, The focus is on research published in Investigative Radiology, supplemented with work from other publications in the few areas not extensively covered by the journal. Studies continue to be performed, although at a low level, examining safety issues. Most preclinical investigations have focused on MR and ultrasound agents. In MR, the research effort is concentrated on the development of targeted agents; in ultrasound, work is focused on the characterization of basic contrast mechanisms. The demonstration of clinical applications is still dominated by work with MR, both in disease models and human investigations. The use of extracellular gadolinium chelates to enhance visualization of blood vessels (the field of contrast-enhanced MR angiography) is the largest single new clinical application of contrast media to emerge in several years. New clinical applications continue to be pursued with contrast media in CT, ultrasound, and x-ray angiography, As intravenously injected ultrasound contrast agents come to market, trials demonstrating clinical applications and subsequent scientific publications,will increase in number.
引用
收藏
页码:785 / 790
页数:6
相关论文
共 102 条
[91]  
Uggowitzer MM, 1999, J ULTRAS MED, V18, P445
[92]   Acoustically active lipospheres containing paclitaxel - A new therapeutic ultrasound contrast agent [J].
Unger, EC ;
McCreery, TP ;
Sweitzer, RH ;
Caldwell, VE ;
Wu, YQ .
INVESTIGATIVE RADIOLOGY, 1998, 33 (12) :886-892
[93]  
Vander Elst L, 1998, INVEST RADIOL, V33, P828
[94]   Biphasic spiral computed tomography versus digital subtraction angiography for evaluation of arterial thrombosis after orthotopic liver transplantation [J].
Vogl, TJ ;
Hänninen, EL ;
Bechstein, WO ;
Neuhaus, P ;
Schumacher, G ;
Felix, R .
INVESTIGATIVE RADIOLOGY, 1998, 33 (03) :136-140
[95]   Comparative toxic effects of iobitridol and iohexol on the kidney [J].
Wasaki, M ;
Kawamura, H ;
Sugimoto, J ;
Shimada, M ;
Satoh, Y ;
Tanaka, E ;
Gemba, M .
INVESTIGATIVE RADIOLOGY, 1998, 33 (07) :393-400
[96]   Effects of inhaled gases on the ultrasound contrast produced by microspheres containing air or perfluoropropane in anesthetized dogs [J].
Wible, J ;
Wojdyla, J ;
Bugaj, J ;
Brandenburger, J .
INVESTIGATIVE RADIOLOGY, 1998, 33 (12) :871-879
[97]   Assessment of vascularity in reactive lymph nodes by means of D-galactose contrast-enhanced Doppler sonography [J].
Willam, C ;
Mäurer, J ;
Schroeder, R ;
Hidajat, N ;
Hell, B ;
Bier, J ;
Weber, S ;
Felix, R .
INVESTIGATIVE RADIOLOGY, 1998, 33 (03) :146-152
[98]   Gadolinium-enhanced magnetic resonance venography of the portal venous system prior to transjugular intrahepatic portosystemic shunts and liver transplantation - Original investigation [J].
Wilson, MW ;
Hamilton, BH ;
Dong, Q ;
Stafford-Johnson, DB ;
Kazanjian, SN ;
Williams, DM ;
Marx, MV ;
Cho, KJ ;
Prince, MR .
INVESTIGATIVE RADIOLOGY, 1998, 33 (09) :644-652
[99]   Binding and lysing of blood clots using MRX-408 [J].
Wu, YQ ;
Unger, EC ;
McCreery, TP ;
Sweitzer, RH ;
Shen, DK ;
Wu, GL ;
Vielhauer, MD .
INVESTIGATIVE RADIOLOGY, 1998, 33 (12) :880-885
[100]   Gadolinium-enhanced magnetic resonance angiography of the aorta - A review [J].
Yamada, CY ;
Grygotis, LA ;
Kaufman, J .
INVESTIGATIVE RADIOLOGY, 1998, 33 (09) :618-627