Automated Ankle-Brachial Pressure Index Measurement by Clinical Staff for Peripheral Arterial Disease Diagnosis in Nondiabetic and Diabetic Patients

被引:19
作者
Clairotte, Cecile [1 ]
Retout, Sylvie [2 ,3 ,4 ]
Potier, Louis [5 ]
Roussel, Ronan [3 ,5 ,6 ]
Escoubet, Brigitte [1 ,3 ,7 ]
机构
[1] Hop Bichat Claude Bernard, AP HP, Dept Physiol Explorat Fonct, F-75877 Paris, France
[2] Hop Bichat Claude Bernard, AP HP, Unite Fonct Biostat, F-75877 Paris, France
[3] Univ Paris Diderot, Unite Format &t Rech Med, Paris, France
[4] Inst Natl Sante & Rech Med, U738, Paris, France
[5] Hop Bichat Claude Bernard, AP HP, Dept Endocrinol Diabetol & Nutr, F-75877 Paris, France
[6] Inst Natl Sante & Rech Med, U695, Paris, France
[7] Inst Natl Sante & Rech Med, U872, Paris, France
关键词
LOWER-EXTREMITY; CARDIOVASCULAR RISK; HEALTH; POPULATION; MORTALITY; MEDICINE; TESTS; CARE;
D O I
10.2337/dc08-2230
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - Peripheral arterial disease (PAD) is a prognostic marker in cardiovascular disease. The use of Doppler-measured ankle-brachial pressure index (Dop-ABI) for PAD diagnosis is limited because of time, required training, and costs. We assessed automated oscillometric measurement of the ankle-brachial pressure index (Osc-ABI) by nurses and clinical staff. RESEARCH DESIGN AND METHODS - Clinical staff obtained Csc-ABI with an automated oscillometric device in 146 patients (83 with diabetes) at the time of Dop-ABI measurement and ultrasound evaluation. RESULTS - Measurements were obtained in Most legs (Dop-ABI 98%; Osc-ABI 95.5%). Dop- and Osc-ABI were significantly related in diabetic and nondiabetic patients With good agreement over a wide range of values. When Dop-ABI <= 0.90 was used as the gold standard for PAD, receiver operating characteristic curve analysis showed that PAD was accurately diagnosed with Osc-ABI in diabetic patients. When ultrasound was used to define PAD, Dop-ABI had better diagnostic performance than Osc-ABI in the whole population and in diabetic patients (P = 0.026). Both methods gave similar results in nondiabetic patients, The cutoff values for the highest sensitivity and specificity for PAD screening were between 1.0 and 1.1. Estimation of cost with the French medical care system fees showed a potential reduction by three of the screening procedures. CONCLUSIONS - PAD screening could be improved by Using Osc-ABI measured by clinical staff with the benefit of greater Cost-effectiveness but at the risk of lower diagnostic performance in diabetic patients.
引用
收藏
页码:1231 / 1236
页数:6
相关论文
共 21 条
[1]   Automated oscillometric determination of the ankle - Brachial index provides accuracy necessary for office practice [J].
Beckman, JA ;
Higgins, CO ;
Gerhard-Herman, M .
HYPERTENSION, 2006, 47 (01) :35-38
[2]   Validation of a new method of detecting peripheral artery disease by determination of ankle-brachial index using an automatic blood pressure device [J].
Benchimol, A ;
Bernard, V ;
Pillois, X ;
Hong, NT ;
Benchimol, D ;
Bonnet, J .
ANGIOLOGY, 2004, 55 (02) :127-134
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[5]   Peripheral artery disease, diabetes, and reduced lower extremity functioning [J].
Dolan, NC ;
Liu, K ;
Criqui, MH ;
Greenland, P ;
Guralnik, JM ;
Chan, CL ;
Schneider, JR ;
Mandapat, AL ;
Martin, G ;
McDermott, MM .
DIABETES CARE, 2002, 25 (01) :113-120
[6]   Prevalence of lower-extremity disease in the US adult population ≥40 years of age with and without diabetes -: 1999-2000 National Health and Nutrition Examination Survey [J].
Gregg, EW ;
Sorlie, P ;
Paulose-Ram, R ;
Gu, QP ;
Eberhardt, MS ;
Wolz, M ;
Burt, V ;
Curtin, L ;
Engelgau, M ;
Geiss, L .
DIABETES CARE, 2004, 27 (07) :1591-1597
[7]   Principles and practical application of the receiver-operating characteristic analysis for diagnostic tests [J].
Greiner, M ;
Pfeiffer, D ;
Smith, RD .
PREVENTIVE VETERINARY MEDICINE, 2000, 45 (1-2) :23-41
[8]  
Hirsch AT, 2006, CIRCULATION, V113, pE463, DOI 10.1161/CIRCULATIONAHA.106.174526
[9]   Peripheral arterial disease detection, awareness, and treatment in primary care [J].
Hirsch, AT ;
Criqui, MH ;
Treat-Jacobson, D ;
Regensteiner, JG ;
Creager, MA ;
Olin, JW ;
Krook, SH ;
Hunninghake, DB ;
Comerota, AJ ;
Walsh, ME ;
McDermott, MM ;
Hiatt, WR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 286 (11) :1317-1324
[10]   CLINICAL-EVALUATION OF SEMIAUTOMATIC AND AUTOMATIC DEVICES FOR HOME BLOOD-PRESSURE MEASUREMENT - COMPARISON BETWEEN CUFF-OSCILLOMETRIC AND MICROPHONE METHODS [J].
IMAI, Y ;
ABE, K ;
SASAKI, S ;
MINAMI, N ;
MUNAKATA, M ;
SAKUMA, H ;
HASHIMOTO, J ;
SEKINO, H ;
IMAI, K ;
YOSHINAGA, K .
JOURNAL OF HYPERTENSION, 1989, 7 (12) :983-990