De novo peptide sequencing via tandem mass spectrometry

被引:422
作者
Dancík, V
Addona, TA
Clauser, KR
Vath, JE
Pevzner, PA
机构
[1] Millennium Pharmaceut, Cambridge, MA 02139 USA
[2] Slovak Acad Sci, Math Inst, Kosice, Slovakia
[3] Univ So Calif, Dept Math, Los Angeles, CA 90089 USA
[4] Univ So Calif, Dept Comp Sci, Los Angeles, CA 90089 USA
[5] Univ So Calif, Dept Mol Biol, Los Angeles, CA 90089 USA
关键词
protein sequencing; mass-spectrometry;
D O I
10.1089/106652799318300
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Peptide sequencing via tandem mass spectrometry (MS/MS) is one of the most powerful tools in proteomics for identifying proteins. Because complete genome sequences are accumulating rapidly, the recent trend in interpretation of MS/MS spectra has been database search. However, de novo MS/MS spectral interpretation remains an open problem typically involving manual interpretation by expert mass spectrometrists. We have developed a new algorithm, SHERENGA, for de novo interpretation that automatically learns fragment ion types and intensity thresholds from a collection of test spectra generated from any type of mass spectrometer, The test data are used to construct optimal path scoring in the graph representations of MS/MS spectra, A ranked list of high scoring paths corresponds to potential peptide sequences. SHERENGA is most useful for interpreting sequences of peptides resulting from unknown proteins and for validating the results of database search algorithms in fully automated, high-throughput peptide sequencing.
引用
收藏
页码:327 / 342
页数:16
相关论文
共 33 条
[1]  
[Anonymous], 1979, Computers and Intractablity: A Guide to the Theoryof NP-Completeness
[2]   FAST ALGORITHM FOR PEPTIDE SEQUENCING BY MASS-SPECTROSCOPY [J].
BARTELS, C .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1990, 19 (06) :363-368
[3]   TANDEM MASS-SPECTROMETRY OF PEPTIDES USING HYBRID AND 4-SECTOR INSTRUMENTS - A COMPARATIVE-STUDY [J].
BEAN, MF ;
CARR, SA ;
THORNE, GC ;
REILLY, MH ;
GASKELL, SJ .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1473-1481
[4]   NOMENCLATURE FOR PEPTIDE FRAGMENT IONS (POSITIVE-IONS) [J].
BIEMANN, K .
METHODS IN ENZYMOLOGY, 1990, 193 :886-887
[5]   Role of accurate mass measurement (±10 ppm) in protein identification strategies employing MS or MS MS and database searching [J].
Clauser, KR ;
Baker, P ;
Burlingame, AL .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2871-2882
[6]  
CLAUSER KR, 1996, 44 ASMS C MASS SPECT, P365
[7]  
CLAUSER KR, 1999, INPRESS PEPTIDE SEQU
[8]  
Cormen TH, 1991, INTRO ALGORITHMS
[9]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[10]  
Fenyo D, 1997, COMPUT APPL BIOSCI, V13, P617