Our aim was to assess the intra- and inter-observer reliability in the establishment of the anterior pelvic plane used in imageless computer-assisted navigation. From this we determined the subsequent effects on version and inclination of the acetabular component. A cadaver model was developed with a specifically-designed rod which held the component tracker at a fixed orientation to the pelvis, leaving the anterior pelvic plane as the only variable. Eight surgeons determined the anterior pelvic plane by palpating and registering the bony landmarks as reference points. The exact anterior pelvic plane was then established by using anatomically-placed bone screws as reference points. The difference between the surgeons was found to be highly significant (p < 0.001). The variation was significantly larger for anteversion (SD 9.6 degrees than for inclination (SD 6.3 degrees). The present method for registering pelvic landmarks shows significant inaccuracy, which highlights the need for improved methods of registration before this technique is considered to be safe.
引用
收藏
页码:972 / 975
页数:4
相关论文
共 9 条
[1]
Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial [J].
Chauhan, SK ;
Scott, RG ;
Breidahl, W ;
Beaver, RJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03) :372-377
[2]
Comparison of a mechanical acetabular alignment guide with computer placement of the socket [J].
DiGioia, AM ;
Jaramaz, B ;
Plakseychuk, AY ;
Moody, JE ;
Nikou, C ;
LaBarca, RS ;
Levison, TJ ;
Picard, F .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :359-364
[3]
Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement [J].
Jolles, BM ;
Genoud, P ;
Hoffmeyer, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) :174-179
[4]
Imageless navigation for insertion of the acetabular component in total hip arthroplasty -: Is it as accurate as CT-based navigation? [J].
Kalteis, T ;
Handel, A ;
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02) :163-167
[5]
Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration [J].
Kennedy, JG ;
Rogers, WB ;
Soffe, KE ;
Sullivan, RJ ;
Griffen, DG ;
Sheehan, LJ .
JOURNAL OF ARTHROPLASTY, 1998, 13 (05) :530-534
[6]
DISLOCATIONS AFTER TOTAL HIP-REPLACEMENT ARTHROPLASTIES [J].
LEWINNEK, GE ;
LEWIS, JL ;
TARR, R ;
COMPERE, CL ;
ZIMMERMAN, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (02) :217-220
[7]
MCCOLLUM DE, 1990, CLIN ORTHOP RELAT R, P159
[8]
Reduced variability of acetabular cup positioning with use of an imageless navigation system [J].
Nogler, M ;
Kessler, O ;
Prassl, A ;
Donnelly, B ;
Streicher, R ;
Sledge, JB ;
Krismer, M .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) :159-163
[9]
Cup aligmuent error model for total hip arthroplasty [J].
Wolf, A ;
DiGioia, AM ;
Mor, AB ;
Jaramaz, B .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (437) :132-137