Solitary pulmonary nodules: Evaluation of blood flow patterns with dynamic CT

被引:206
作者
Zhang, MM
Kono, M
机构
[1] Department of Radiology, Kobe University, School of Medicine, Chuo-ku, Kobe 650, Kusunoki-cho
关键词
aorta; flow dynamics; computed tomography; contrast enhancement; lung; nodule; lung neoplasms; CT; diagnosis;
D O I
10.1148/radiology.205.2.9356631
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the efficacy of dynamic computed tomography (CT) for differentiating benign from malignant solitary pulmonary nodules (SPNs). MATERIALS AND METHODS: Sixty-five patients with noncalcified SPNs (diameter, less than or equal to 30 mm; 42 malignant, 16 benign, seven inflammatory) underwent single-location dynamic contrast material-enhanced (100 mL, 4 mL/sec) serial CT. Peak height of time-attenuation curves and ratio of peak height of the SPN to that of the aorta were measured. Precontrast attenuation and enhancement pattern were recorded. Perfusion was calculated from the maximum gradient of the time-attenuation curve and the peak height of the aorta. RESULTS: Peak heights of malignant (41.9 HU +/- 2.8) and inflammatory (43.6 HU +/- 7.7) SPNs were significantly higher than that (13.4 HU +/- 2.2) of benign SPNs (P <.001; P < .01). SPN-to-aorta ratios in malignant and inflammatory SPNs were significantly higher than that in benign SPNs (P <.001, P <.05). No statistically significant differences in the peak height and SPN-to-aorta ratio were found between malignant and inflammatory SPNs. Precontrast attenuation of inflammatory SPNs was lower than that of malignant SPNs (P <.05). Perfusion values in malignant and inflammatory SPNs were significantly higher than that of the benign SPNs (P <.01). CONCLUSION: Dynamic CT provides quantitative information about blood flow patterns of SPNs and is an applicable diagnostic method for differentiating SPNs.
引用
收藏
页码:471 / 478
页数:8
相关论文
共 50 条
  • [11] Effect of rate of contrast medium injection on hepatic enhancement at CT
    Garcia, PA
    Bonaldi, VM
    Bret, PM
    Liang, LJ
    Reinhold, C
    Atri, M
    [J]. RADIOLOGY, 1996, 199 (01) : 185 - 189
  • [12] Guckel C, 1996, RADIOLOGY, V200, P681
  • [13] SOLITARY PULMONARY NODULES - DETECTION OF MALIGNANCY WITH PET WITH 2-[F-18]-FLUORO-2-DEOXY-D-GLUCOSE
    GUPTA, NC
    FRANK, AR
    DEWAN, NA
    REDEPENNING, LS
    ROTHBERG, ML
    MAILLIARD, JA
    PHALEN, JJ
    SUNDERLAND, JJ
    FRICK, MP
    [J]. RADIOLOGY, 1992, 184 (02) : 441 - 444
  • [14] DYNAMIC INCREMENTAL CT - EFFECT OF VOLUME AND CONCENTRATION OF CONTRAST MATERIAL AND PATIENT WEIGHT ON HEPATIC ENHANCEMENT
    HEIKEN, JP
    BRINK, JA
    MCCLENNAN, BL
    SAGEL, SS
    CROWE, TM
    GAINES, MV
    [J]. RADIOLOGY, 1995, 195 (02) : 353 - 357
  • [15] JAIN RK, 1988, CANCER RES, V48, P2641
  • [16] DYNAMIC CONTRAST ENHANCEMENT OF THE UPPER ABDOMEN - EFFECT OF CONTRAST-MEDIUM AND BODY-WEIGHT
    KORMANO, M
    PARTANEN, K
    SOIMAKALLIO, S
    KIVIMAKI, T
    [J]. INVESTIGATIVE RADIOLOGY, 1983, 18 (04) : 364 - 367
  • [17] EXTRAVASCULAR CONTRAST MATERIAL - MAJOR COMPONENT OF CONTRAST ENHANCEMENT
    KORMANO, M
    DEAN, PB
    [J]. RADIOLOGY, 1976, 121 (02) : 379 - 382
  • [18] GADOPENTETATE-DIMEGLUMINE-ENHANCED MAGNETIC-RESONANCE-IMAGING FOR LUNG NODULES - DIFFERENTIATION OF LUNG-CANCER AND TUBERCULOMA
    KUSUMOTO, M
    KONO, M
    ADACHI, S
    YAMASAKI, K
    ITOUJI, E
    SAKAI, E
    ENDO, M
    NAKAMURA, T
    KIMURA, K
    [J]. INVESTIGATIVE RADIOLOGY, 1994, 29 : S255 - S256
  • [19] Diagnostic accuracy and safety of CT-Guided percutaneous needle aspiration biopsy of the lung: Comparison of small and large pulmonary nodules
    Li, HQ
    Boiselle, PM
    Shepard, JAO
    TrotmanDickenson, B
    McLoud, TC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) : 105 - 109
  • [20] PULMONARY MASSES - CONTRAST ENHANCEMENT
    LITTLETON, JT
    DURIZCH, ML
    MOELLER, G
    HERBERT, DE