Quantitative analysis of clenbuterol in meat products using liquid chromatography-electrospray ionisation tandem mass spectrometry

被引:42
作者
Guy, PA [1 ]
Savoy, MC [1 ]
Stadler, RH [1 ]
机构
[1] Nestec Ltd, Nestle Res Ctr, Dept Qual & Safety Assurance, CH-1000 Lausanne, Switzerland
来源
JOURNAL OF CHROMATOGRAPHY B | 1999年 / 736卷 / 1-2期
关键词
clenbuterol; growth hormones;
D O I
10.1016/S0378-4347(99)00466-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method is presented that allows quantitation of clenbuterol in meat and liver products at the ng/kg level by liquid chromatography-electrospray ionisation tandem mass spectrometry (LC-ESIMS-MS) using a stable isotopically labeled internal standard. The practical procedure involves acid extraction followed by two solid-phase clean-up steps with C-18 and strong cation-exchange (SCX) resins. The typical recovery of the analyte spiked at 0.4 mu g/kg in meat and liver samples was at 63+/-7%. Mass spectral acquisition was done in multiple reaction monitoring (MRM) to provide a high degree of sensitivity, achieving a limit of detection and quantitation at 10 and 15 ng/kg, respectively. Two precursor ions at m/z 277 and 279, corresponding to the characteristic isotopic cluster of the two chlorine atoms of clenbuterol, were monitored by LC-ESIMS-MS to provide unambiguous identity of the analyte. Samples of meat and liver of various origins with either incurred residues or spiked with known amounts of clenbuterol were used to validate the method. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:209 / 219
页数:11
相关论文
共 24 条
[1]  
[Anonymous], 1996, WHO FOOD ADD SER, V38, P3
[2]  
Biancotto G, 1997, J MASS SPECTROM, V32, P781, DOI 10.1002/(SICI)1096-9888(199707)32:7<781::AID-JMS532>3.0.CO
[3]  
2-5
[4]   MATRIX SOLID-PHASE DISPERSION AS A MULTIRESIDUE EXTRACTION TECHNIQUE FOR BETA-AGONISTS IN BOVINE LIVER-TISSUE [J].
BOYD, D ;
OKEEFFE, M ;
SMYTH, MR .
ANALYST, 1994, 119 (07) :1467-1470
[5]   DETERMINATION OF CLENBUTEROL IN BOVINE LIVER BY ENZYME-IMMUNOASSAY [J].
BUCKNALL, SD ;
MACKENZIE, AL ;
SAUER, MJ ;
EVEREST, DJ ;
NEWMAN, R ;
JACKMAN, R .
ANALYTICA CHIMICA ACTA, 1993, 275 (1-2) :227-230
[6]   Quantitative multi-residue determination of beta-agonists in bovine urine using on-line immunoaffinity extraction coupled column packed capillary liquid chromatography tandem mass spectrometry [J].
Cai, J ;
Henion, J .
JOURNAL OF CHROMATOGRAPHY B, 1997, 691 (02) :357-370
[7]   ROBUST STATISTICS IN ANALYTICAL-CHEMISTRY [J].
DANZER, K .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (08) :869-875
[8]  
Debrauwer L, 1997, RAPID COMMUN MASS SP, V11, P1089, DOI 10.1002/(SICI)1097-0231(19970630)11:10<1089::AID-RCM978>3.0.CO
[9]  
2-R
[10]   DETERMINATION OF CLENBUTEROL RESIDUES BY LIQUID-CHROMATOGRAPHY ELECTROSPRAY MASS-SPECTROMETRY [J].
DEBRAUWER, L ;
BORIES, G .
ANALYTICA CHIMICA ACTA, 1993, 275 (1-2) :231-239