A mobile EEG system with dry electrodes

被引:42
作者
Gargiulo, Gaetano [1 ,2 ]
Bifulco, Paolo [2 ]
Calvo, Rafael A. [1 ]
Cesarelli, Mario [2 ]
Jin, Craig [1 ]
van Schaik, Andre [1 ]
机构
[1] Univ Sydney, Sch Elect & Informat Engn, Sydney, NSW 2006, Australia
[2] Univ Naples Federico II, DIET, Naples, Italy
来源
2008 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE - INTELLIGENT BIOMEDICAL SYSTEMS (BIOCAS) | 2008年
关键词
EEG; bio-signal amplifier; dry electrodes; brain computer interfaces; neurofeedback;
D O I
10.1109/BIOCAS.2008.4696927
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A new EEG recording device demonstrating an ultra-high input impedance is presented. Dry electrodes made of conductive rubber were employed for this study with careful shielding of the electrodes and cables. The device has a small form factor, so it is wearable, and has continuous Bluetooth connectivity. Tests were performed to assess features of the proposed device and to compare it with standard clinical devices. Simultaneous EEG recordings were measured from adjacent sites on the scalp using the new EEG device with dry electrodes and a reference EEG device with standard electrodes. The gain and bandwidth settings for the two devices were set similarly. Traditional closing eyes alpha-wave replacement and mu-rhythm were compared in both the time and frequency domains. Results from eight subjects show a high correlation coefficient (0.83 on average) between recordings of contiguous dry and standard electrodes. We conclude that the performance of the new device is comparable with standard EEG recording equipment, but offers a shorter set-up time, the possibility of long-term recording, and a wireless connection - all of which are advantages valuable in the field of brain computer interfaces and neurofeedback.
引用
收藏
页码:273 / +
页数:2
相关论文
共 11 条
[1]  
Artz W, 1970, Biomed Eng, V5, P300
[2]  
Dornhege G., 2007, BRAIN COMPUTER INTER
[3]  
Evans J.Abarbanel., 1999, Introduction to Quantitative EEG and neurofeedback
[4]  
HOWITZ P, 2002, ART ELECT
[5]   WEARABLE ELECTROENCEPHALOGRAPH SYSTEM WITH PREAMPLIFIED ELECTRODES [J].
IGUCHI, H ;
WATANABE, K ;
KOZATO, A ;
ISHII, N .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1994, 32 (04) :459-461
[6]  
Mohanan P. V., 1995, BIOCOMPATIBILITY STU, p4/12
[7]   Single Trial Classification of Motor Imagination Using 6 Dry EEG Electrodes [J].
Popescu, Florin ;
Fazli, Siamac ;
Badower, Yakob ;
Blankertz, Benjamin ;
Mueller, Klaus-R. .
PLOS ONE, 2007, 2 (07)
[8]  
PRIOR PF, 1986, MONITORING CEREBRAL
[9]   A direct comparison of wet, dry and insulating bioelectric recording electrodes [J].
Searle, A ;
Kirkup, L .
PHYSIOLOGICAL MEASUREMENT, 2000, 21 (02) :271-283
[10]  
Webster JG, 1998, MED INSTRUMENTATION