A wireless, remote query glucose biosensor based on a pH-sensitive polymer

被引:129
作者
Cai, QY
Zeng, KF
Ruan, CM
Desai, TA
Grimes, CA
机构
[1] Penn State Univ, Dept Elect Engn, University Pk, PA 16802 USA
[2] Penn State Univ, Dept Mat Sci & Engn, University Pk, PA 16802 USA
[3] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
关键词
D O I
10.1021/ac0498516
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a wireless, remote query glucose biosensor using a ribbonlike, mass-sensitive magnetoelastic sensor as the transducer. The glucose biosensor is fabricated by first coating the magnetoelastic sensor with a pH-sensitive polymer and upon it a layer of glucose oxidase (GOx). The pH-responsive polymer swells or shrinks, thereby changing mass, respectively, in response to increasing or decreasing pH values. The GOx-catalyzed oxidation of glucose produces gluconic acid, inducing the pH-responsive polymer to shrink, which in turn decreases the polymer mass. In response to a time-varying magnetic field, a magnetoelastic sensor mechanically vibrates at a characteristic resonance frequency, the value of which inversely depends on sensor mass loading. As the magnetoelastic films are magnetostrictive, the vibrations launch magnetic flux that can be remotely detected using a pickup coil. Hence, changes in the resonance frequency of a passive magnetoelastic transducer are detected on a remote query basis, without the use of physical connections to the sensors. The sensitivity of the glucose biosensors decreases with increasing ionic strength; at physiological salt concentrations, 0.6 mmol/L of glucose can be measured. At glucose concentrations of 1 - 10 mmol/ L, the biosensor response is reversible and linear, with the detection limit of 0.6 mmol/L corresponding to an error in resonance frequency determination of 20 Hz. Since no physical connections between the sensor and the monitoring instrument are required, this sensor can potentially be applied to in vivo and in situ measurement of glucose concentrations.
引用
收藏
页码:4038 / 4043
页数:6
相关论文
共 39 条
  • [1] Photonic crystal carbohydrate sensors: Low ionic strength sugar sensing
    Asher, SA
    Alexeev, VL
    Goponenko, AV
    Sharma, AC
    Lednev, IK
    Wilcox, CS
    Finegold, DN
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (11) : 3322 - 3329
  • [2] Dynamic delay and maximal dynamic error in continuous biosensors
    Baker, DA
    Gough, DA
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (08) : 1292 - 1297
  • [3] Multicomponent blood analysis by near-infrared Raman spectroscopy
    Berger, AJ
    Koo, TW
    Itzkan, I
    Horowitz, G
    Feld, MS
    [J]. APPLIED OPTICS, 1999, 38 (13) : 2916 - 2926
  • [4] Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor
    Boyne, MS
    Silver, DM
    Kaplan, J
    Saudek, CD
    [J]. DIABETES, 2003, 52 (11) : 2790 - 2794
  • [5] A remote query magnetoelastic pH sensor
    Cai, QY
    Grimes, CA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 71 (1-2) : 112 - 117
  • [6] A wireless, remote query magnetoelastic CO2 sensor
    Cai, QY
    Cammers-Goodwin, A
    Grimes, CA
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 2000, 2 (06): : 556 - 560
  • [7] A wireless, remote query ammonia sensor
    Cai, QY
    Jain, MK
    Grimes, CA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (03) : 614 - 619
  • [8] Cameron BD, 1999, DIABETES TECHNOL THE, V1, P125
  • [9] In situ assembled mass-transport controlling micromembranes and their application in implanted amperometric glucose sensors
    Chen, T
    Friedman, KA
    Lei, I
    Heller, A
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (16) : 3757 - 3763
  • [10] Saccharide detection based on the amplified fluorescence quenching of a water-soluble poly(phenylene ethynylene) by a boronic acid functionalized benzyl viologen derivative
    DiCesare, N
    Pinto, MR
    Schanze, KS
    Lakowicz, JR
    [J]. LANGMUIR, 2002, 18 (21) : 7785 - 7787