Comparison of a sliding hip screw with a trochanteric lateral support plate to an intramedullary hip screw for fixation of unstable intertrochanteric hip fractures: A Cadaver study

被引:48
作者
Bong, MR [1 ]
Patel, V [1 ]
Iesaka, K [1 ]
Egol, KA [1 ]
Kummer, FJ [1 ]
Koval, KJ [1 ]
机构
[1] NYU, Dept Orthopaed Surg, Hosp Joint Dis, New York, NY 10003 USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2004年 / 56卷 / 04期
关键词
biomechanics; hip fracture; sliding hip screw; intramedullary fixation;
D O I
10.1097/01.TA.0000046265.44785.0C
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. The lateral trochanteric support plate (LSP) was developed to prevent excessive sliding of unstable intertrochanteric femur fractures fixed with a sliding hip screw (SHS). This study compared the fracture stability and screw sliding characteristics of unstable intertrochanteric femur fractures fixed with either an SHS and LSP or an Intramedullary Hip Screw (IMHS). Methods. Six matched pairs of cadaveric human femurs with simulated, unstable intertrochanteric femur fractures were stabilized with either an IMHS or a 135-degree SHS with an attached LSP. Inferior and lateral head displacements and lag screw sliding distances were measured for applied static loads of 750 N, before and after cycling. Results: Four-part unstable intertrochanteric femur fractures showed comparable screw sliding characteristics and stability whether instrumented with an SHS and LSP or an IMHS. Conclusion: A sliding hip screw with an attached lateral support plate provides stability and ability to resist medial displacement of the femoral shaft similar to that seen with the IMHS.
引用
收藏
页码:791 / 794
页数:4
相关论文
共 24 条
[1]   Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur [J].
Adams, CI ;
Robinson, CM ;
Court-Brown, CM ;
McQueen, MM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (06) :394-400
[2]   GAMMA-NAIL VS COMPRESSION SCREW FOR TROCHANTERIC FEMORAL FRACTURES - 15 REOPERATIONS IN A PROSPECTIVE, RANDOMIZED STUDY OF 378 PATIENTS [J].
AUNE, AK ;
EKELAND, A ;
ODEGAARD, B ;
GROGAARD, B ;
ALHO, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (02) :127-130
[3]  
BABST R, 1993, HELV CHIR ACTA, V59, P521
[4]   Clinical results using the trochanter stabilizing plate (TSP): The modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures [J].
Babst, R ;
Renner, N ;
Biedermann, M ;
Rosso, R ;
Heberer, M ;
Harder, F ;
Regazzoni, P .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (06) :392-399
[5]  
Bess R J, 1997, J South Orthop Assoc, V6, P173
[6]  
Boriani S, 1990, Chir Organi Mov, V75, P67
[7]   FIXATION OF INTERTROCHANTERIC FRACTURES OF THE FEMUR - A RANDOMIZED PROSPECTIVE COMPARISON OF THE GAMMA-NAIL AND THE DYNAMIC HIP SCREW [J].
BRIDLE, SH ;
PATEL, AD ;
BIRCHER, M ;
CALVERT, PT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02) :330-334
[8]  
CHANG WS, 1987, CLIN ORTHOP RELAT R, V225, P141
[9]   PROXIMAL FEMORAL FRACTURES - A BIOMECHANICAL STUDY TO COMPARE INTRAMEDULLARY AND EXTRAMEDULLARY FIXATION [J].
CURTIS, MJ ;
JINNAH, RH ;
WILSON, V ;
CUNNINGHAM, BW .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1994, 25 (02) :99-104
[10]   INTERTROCHANTERIC FEMORAL FRACTURES - MECHANICAL FAILURE AFTER INTERNAL-FIXATION [J].
DAVIS, TRC ;
SHER, JL ;
HORSMAN, A ;
SIMPSON, M ;
PORTER, BB ;
CHECKETTS, RG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01) :26-31