Evaluation of a target contouring protocol for 3D conformal radiotherapy in non-small cell lung cancer

被引:120
作者
Senan, S
de Koste, JV
Samson, M
Tankink, H
Jansen, P
Nowak, PJCM
Krol, ADG
Schmitz, P
Lagerwaard, FJ
机构
[1] Univ Rotterdam Hosp, Dr Daniel den Hoed Canc Ctr, Dept Radiat Oncol, NL-3075 EA Rotterdam, Netherlands
[2] Univ Rotterdam Hosp, Dr Daniel den Hoed Canc Ctr, Dept Stat, NL-3075 EA Rotterdam, Netherlands
关键词
conformal radiotherapy; non-small cell lung cancer; target contouring; inter-clinician variability;
D O I
10.1016/S0167-8140(99)00143-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: A protocol for the contouring of target volumes in lung cancer was implemented. Subsequently, a study was performed in order to determine the intra and inter-clinician variations in contoured volumes. Materials and methods: Six radiation oncologists (RO) contoured the gross tumour volume (GTV) and/or clinical target volume (CTV), and planning target volume (PTV) for three patients with non-small cell lung cancer (NSCLC), on two separate occasions. These were, respectively, a well-circumscribed T1N0M0 lesion, an irregularly shaped T2N0M0 lesion, and a T2N2M0 tumour. Detailed diagnostic radiology reports were provided and contours were entered into a 3D planning system. The target volumes were calculated and beams-eye view (BEV) plots were generated to visualise differences in contouring. A software tool was used to expand the GTV and CTV in three dimensions for an automatically derived PTV. Results: Significant inter-RO variations in contoured target volumes were observed for all patients, and these were greater than intra-RO differences. The ratio of the largest to smallest contoured volume ranged from 1.6 for the GTV in the T1N0 lesion, to 2.0 for the PTV in the T2N2 lesion. The BEV plots revealed significant inter-RO variations in contouring the mediastinal CTV. The PTV's derived using a 3D margin programme were larger than manually contoured PTV's. These variations did not correlate with the experience of ROs. Conclusions: Despite the use of an institutional contouring protocol, significant interclinician variations persist in contouring target volumes in NSCLC. Additional measures to decrease such variations should be incorporated into clinical trials. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:247 / 255
页数:9
相关论文
共 26 条
[1]   Target volume definition for three-dimensional conformal radiation therapy of lung cancer [J].
Armstrong, JG .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (846) :587-594
[2]   Measurement error and correlation coefficients [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 313 (7048) :41-42
[3]  
Bland JM, 1996, BRIT MED J, V313, P744
[4]   Interphysician variability in defining the planning target volume in the irradiation of prostate and seminal vesicles [J].
Cazzaniga, LF ;
Marinoni, MA ;
Bossi, A ;
Bianchi, E ;
Cagna, E ;
Cosentino, D ;
Scandolaro, L ;
Valli, M ;
Frigerio, M .
RADIOTHERAPY AND ONCOLOGY, 1998, 47 (03) :293-296
[5]  
DEBOIS M, 1998, RADIOTHER ONCOL, V48, pS13
[6]   What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer? [J].
Ekberg, L ;
Holmberg, O ;
Wittgren, L ;
Bjelkengren, G ;
Landberg, T .
RADIOTHERAPY AND ONCOLOGY, 1998, 48 (01) :71-77
[7]   3-DIMENSIONAL RADIATION TREATMENT PLANNING STUDY FOR PATIENTS WITH CARCINOMA OF THE LUNG [J].
GRAHAM, MV ;
MATTHEWS, JW ;
HARMS, WB ;
EMAMI, B ;
GLAZER, HS ;
PURDY, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 29 (05) :1105-1117
[8]  
Hamilton C S, 1992, Clin Oncol (R Coll Radiol), V4, P141, DOI 10.1016/S0936-6555(05)81075-1
[9]   THE EFFECT ON APPARENT SIZE OF SIMULATED PULMONARY NODULES OF USING 3 STANDARD CT WINDOW SETTINGS [J].
HARRIS, KM ;
ADAMS, H ;
LLOYD, DCF ;
HARVEY, DJ .
CLINICAL RADIOLOGY, 1993, 47 (04) :241-244
[10]  
HAYMAN JA, 1999, J CLIN ONCOL, V18, pA459