Open tubular liquid chromatography using a sol-gel derived stationary phase

被引:32
作者
Guo, Y [1 ]
Colon, LA [1 ]
机构
[1] SUNY BUFFALO,DEPT CHEM,BUFFALO,NY 14260
关键词
column liquid chromatography; open tubular columns; sol-gel coatings; laser-induced fluorescence detection;
D O I
10.1007/BF02292997
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An organically modified silica glass material containing octyl groups (C-8) was fabricated by the sol-gel process and coated onto the inner walls of fused silica capillaries. The coating was used as the stationary phase for reversed-phase open tubular liquid chromatography (OTLC). The sol-gel process facilitated the fabrication of a porous silica glass layer with the stationary phase in one single step. The high surface area of the coating, characteristic of materials fabricated by the sol-gel process, resulted in capillary columns with a stronger retention than those prepared by a conventional procedure. The molar ratio of the precursors was used as a tunable parameter to adjust the retention and selectivity of the stationary phase. The column performance was evaluated using anthracene derivatives as model analytes which were monitored by laser-induced fluorescence (LIF) detection. Separation efficiencies of 200,000 theoretical plates/meter were typical for the model compounds. Solute selectivity of the sol-gel derived stationary phase was found to be similar to the selectivity of HPLC monomeric-type phases.
引用
收藏
页码:477 / 483
页数:7
相关论文
共 31 条
[1]   USE OF TAYLOR-ARIS DISPERSION FOR MEASUREMENT OF A SOLUTE DIFFUSION-COEFFICIENT IN THIN CAPILLARIES [J].
BELLO, MS ;
REZZONICO, R ;
RIGHETTI, PG .
SCIENCE, 1994, 266 (5186) :773-776
[2]  
BRINKER CJ, 1989, SOL GEL SCI
[3]   ESTIMATION OF THE INSTRUMENTAL BAND BROADENING CONTRIBUTION TO THE COLUMN ELUTION PROFILES IN OPEN TUBULAR CAPILLARY LIQUID-CHROMATOGRAPHY [J].
CLAESSENS, HA ;
HETEM, MJJ ;
LECLERCQ, PA ;
CRAMERS, CA .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (02) :176-180
[4]   PREPARATION OF OPEN-TUBULAR COLUMNS FOR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CREGO, AL ;
DIEZMASA, JC ;
DABRIO, MV .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1615-1621
[5]  
DLUZNESKI PR, 1985, J HIGH RES CHROMATOG, V8, P248
[6]  
DORSEY JG, 1994, ANAL CHEM, V66, pR531
[7]   PERFORMANCE AND PREPARATION OF IMMOBILIZED POLYSILOXANE STATIONARY PHASES IN 5-55 MU-M ID OPEN-TUBULAR FUSED-SILICA COLUMNS FOR LIQUID-CHROMATOGRAPHY [J].
FOLESTAD, S ;
JOSEFSSON, B ;
LARSSON, M .
JOURNAL OF CHROMATOGRAPHY, 1987, 391 (02) :347-372
[8]   STUDY OF POLYORGANOSILOXANES (NATIVE AND SOLVENT SWOLLEN) FOR THE PREPARATION OF NARROW (5-15 MU-M ID) AND LONG (1-6 M) OPEN-TUBULAR COLUMNS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
GOHLIN, K ;
LARSSON, M .
JOURNAL OF CHROMATOGRAPHY, 1993, 645 (01) :41-56
[9]   VINYL MODIFICATION OF FUSED-SILICA SURFACES IN POLYSILOXANE-COATED 10-50 MU-M I D CAPILLARIES FOR OPEN-TUBULAR LIQUID-CHROMATOGRAPHY [J].
GOHLIN, K ;
LARSSON, M .
JOURNAL OF CHROMATOGRAPHY, 1993, 634 (01) :31-39
[10]   MODIFICATION OF THE INNER CAPILLARY SURFACE BY THE SOL-GEL METHOD - APPLICATION TO OPEN-TUBULAR ELECTROCHROMATOGRAPHY [J].
GUO, Y ;
COLON, LA .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1995, 7 (05) :485-491