Premature ventricular contractions during triggered imaging with ultrasound contrast

被引:105
作者
van der Wouw, PA
Brauns, AC
Bailey, SE
Powers, JE
Wilde, AAA
机构
[1] Onze Lieve Vrouwe Gasthuis, Dept Cardiol, NL-1091 HA Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Cardiol, NL-1105 AZ Amsterdam, Netherlands
[3] Andaris Ltd, Nottingham, England
[4] ATL Ultrasound Inc, Bothell, WA USA
关键词
D O I
10.1067/mje.2000.103865
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Premature ventricular contractions (PVCs) were observed during triggered second harmonic imaging of a contrast agent for myocardial perfusion assessment, with continuous infusion of the contrast agent. Further investigation into the relation of this phenomenon to both ultrasound energy and the contrast agent was carried out during a subsequent bolus-versus-infusion study. Methods and Results: Two open-label studies in healthy male volunteers were performed. The initial study was a dose-response study in 10 subjects, which compared 3 infusion rates. Each volunteer received 3 continuous infusions with different infusion rates of the contrast agent for either 10 (n = 6) or 20 (n = 4) minutes. End-systolic triggered imaging with a mechanical index (MI) of 1.5 was used throughout this part of the study. The second study compared bolus injection with a continuous infusion in 9 volunteers, with a single-dose level but different imaging modalities: end-systolic and end-diastolic triggered imaging at MIs of both 1.1 and 1.5. Spontaneous baseline PVCs were uncommon: 10 in 344 minutes (0.03 PVC/min, maximal 1 PVC/min) of baseline imaging. During end-diastolic triggering, no increase in PVCs was seen, irrespective of MI. A significant increase to 1.06 PVC/min (P < .001) was seen during end-systolic imaging with an MI of 1.5, but not with an MI of 1.1, The increase in WC rate was dose-dependent in the initial study. Conclusion: Imaging of contrast agents with high acoustic pressures can cause PVCs if end-systolic triggering is used. This effect is related to both the dose of contrast agent and acoustic pressure. It does not occur during end-diastolic triggered imaging. Precautionary measures would include using lower MIs or end-diastolic triggering.
引用
收藏
页码:288 / 294
页数:7
相关论文
共 12 条
[1]   Bioeffects of positive and negative acoustic pressures in vivo [J].
Bailey, MR ;
Dalecki, D ;
Child, SZ ;
Raeman, CH ;
Penney, DP ;
Blackstock, DT ;
Carstensen, EL .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 100 (06) :3941-3946
[2]   BIOEFFECTS IN ECHOCARDIOGRAPHY [J].
CARSTENSEN, EL ;
DUCK, FA ;
MELTZER, RS ;
SCHWARZ, KQ ;
KELLER, B .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1992, 9 (06) :605-623
[3]  
*CTR DEV RAD HLTH, 1993, REV 510K DIAGN ULTR
[4]   EFFECTS OF PULSED ULTRASOUND ON THE FROG-HEART .1. THRESHOLDS FOR CHANGES IN CARDIAC-RHYTHM AND AORTIC PRESSURE [J].
DALECKI, D ;
KELLER, BB ;
RAEMAN, CH ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (05) :385-390
[5]   CARDIAC-ARRHYTHMIAS DURING NONSYNCHRONIZED EXTRACORPOREAL SHOCK-WAVE LITHOTRIPSY [J].
GREENSTEIN, A ;
KAVER, I ;
LECHTMAN, V ;
BRAF, Z .
JOURNAL OF UROLOGY, 1995, 154 (04) :1321-1322
[6]   Thresholds for premature contractions in murine hearts exposed to pulsed ultrasound [J].
MacRobbie, AG ;
Raeman, CH ;
Child, SZ ;
Dalecki, D .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (05) :761-765
[7]  
Meltzer R S, 1996, J Am Soc Echocardiogr, V9, P216, DOI 10.1016/S0894-7317(96)90035-8
[8]   A review of in vitro bioeffects of inertial ultrasonic cavitation from a mechanistic perspective [J].
Miller, MW ;
Miller, DL ;
Brayman, AA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (09) :1131-1154
[9]   Direct in vivo visualization of intravascular destruction of microbubbles by ultrasound and its local effects on tissue [J].
Skyba, DM ;
Price, RJ ;
Linka, AZ ;
Skalak, TC ;
Kaul, S .
CIRCULATION, 1998, 98 (04) :290-293
[10]  
VANDERWOUW PA, 1998, J AM COLL CARDIOL SC, V31, pC292