The role of ambient conditions on the performance of a planar, air-breathing hydrogen PEM fuel cell

被引:100
作者
Fabian, Tibor
Posner, Jonathan D.
O'Hayre, Ryan
Cha, Suk-Won
Eaton, John K.
Prinz, Fritz B.
Santiago, Juan G.
机构
[1] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
[2] Arizona State Univ, Dept Mech & Aerosp Engn, Tempe, AZ 85287 USA
[3] Seoul Natl Univ, Sch Mech & Aerosp Engn, Seoul 151744, South Korea
关键词
hydrogen fuel cell; natural convection; planar fuel cell; air-breathing fuel cell; dead-ended anode; shadowgraphy;
D O I
10.1016/j.jpowsour.2006.03.054
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper presents experimental data on the effects of varying ambient temperature (10-40 degrees C) and relative humidity (20-80%) on the operation of a free-breathing fuel cell operated on dry-hydrogen in dead ended mode. We visualize the natural convection plume around the cathode using shadowgraphy, measure the gas diffusion layer (GDL) surface temperature and accumulation of water at the cathode, as well as obtain polarization curves and impedance spectra. The average free-convection air speed was 9.1, cm s(-1) and 11.2 cm s(-1) in horizontal and vertical cell orientations, respectively. We identified three regions of operation characterized by increasing current density: partial membrane hydration, full membrane hydration with GDL flooding, and membrane dry-out. The membrane transitions from the fully hydrated state to a dry out regime at a GDL temperature of approximately 60 degrees C, irrespective of the ambient temperature and humidity conditions. The cell exhibits strong hysteresis and the dry membrane regime cannot be captured by a sweeping polarization scan without complete removal of accumulated water after each measurement point. Maximum power density of 356 mW cm(-2) was measured at an ambient temperature of 20 degrees C and relative humidity of 40%. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:168 / 182
页数:15
相关论文
共 30 条
[1]  
BIRCH G, 1998, METROLOGIA, V35
[2]  
BIRCH KP, 1993, METROLOGIA, V30
[3]   Li-ion batteries and portable power source prospects for the next 5-10 years [J].
Broussely, M ;
Archdale, G .
JOURNAL OF POWER SOURCES, 2004, 136 (02) :386-394
[4]   Performance of polymer electrolyte membrane fuel cell (PEMFC) stacks Part I. Evaluation and simulation of an air-breathing PEMFC stack [J].
Chu, D ;
Jiang, RZ .
JOURNAL OF POWER SOURCES, 1999, 83 (1-2) :128-133
[5]   Electrochemical impedance study of PEM fuel cells. Experimental diagnostics and modeling of air cathodes [J].
Ciureanu, M ;
Roberge, R .
JOURNAL OF PHYSICAL CHEMISTRY B, 2001, 105 (17) :3531-3539
[6]   Fuel cells for portable applications [J].
Dyer, CK .
JOURNAL OF POWER SOURCES, 2002, 106 (1-2) :31-34
[7]  
EDLEN B, 1966, METROLOGIA, V2
[8]   Evaluation of planar free-breathing polymer electrolyte membrane fuel cell design [J].
Hottinen, T ;
Mikkola, M ;
Lund, P .
JOURNAL OF POWER SOURCES, 2004, 129 (01) :68-72
[9]   Effect of ambient conditions on performance and current distribution of a polymer electrolyte membrane fuel cell [J].
Hottinen, T ;
Noponen, M ;
Mennola, T ;
Himanen, O ;
Mikkola, M ;
Lund, P .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2003, 33 (3-4) :265-271
[10]  
INCROPERA FP, 1996, FUNDAMENTALS HEAT MA, P487