Iron isotope ratio measurements by negative thermal ionisation mass spectrometry using FeF4- molecular ions

被引:73
作者
Walczyk, T
机构
来源
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES | 1997年 / 161卷 / 1-3期
关键词
iron; isotope ratio measurement; negative thermal ionisation mass spectrometry;
D O I
10.1016/S0168-1176(96)04532-6
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Based on the formation of molecular FeF4- ions under thermal ion source conditions, a negative thermal ionisation technique for iron was developed. Compared with the widely used iron isotopic analysis by positive thermal ionisation mass spectrometry, a better control of mass-dependent isotopic fractionation is possible by generating molecular FeF4- ions instead of an atomic Fe+ ion beam at comparable ionisation efficiencies. In comparison with the positive thermal ionisation technique, an improvement in the internal (in-run) and external (between-nm) precision by a factor of three to four under equivalent experimental conditions was achieved by this approach. Using a magnetic sector field mass spectrometer and multiple ion beam detection, external precisions well below 0.1% were obtained for the different iron isotope ratios without normalisation of the isotopic data. Using the Fe-54/Fe-56 isotope ratio as an internal standard for normalisation, external precisions of 0.006% for the Fe-57/Fe-58 isotope ratio and 0.02% for the Fe-58/Fe-56 isotope ratio were obtained for an iron sample of natural isotopic composition. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:217 / 227
页数:11
相关论文
共 35 条
  • [31] VOLKENING J, 1989, ASTROPHYS J, V347, pL43, DOI 10.1086/185603
  • [32] NEGATIVE THERMAL IONIZATION MASS-SPECTROMETRY OF MAIN GROUP ELEMENTS .1. 5TH GROUP - PHOSPHORUS, ARSENIC AND ANTIMONY
    WACHSMANN, M
    HEUMANN, KG
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 108 (01): : 75 - 86
  • [33] LOW BLANK RHENIUM ISOTOPE RATIO DETERMINATIONS BY V2O5 COATED NICKEL FILAMENTS USING NEGATIVE THERMAL IONIZATION MASS-SPECTROMETRY
    WALCZYK, T
    HEBEDA, EH
    HEUMANN, KG
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 130 (03): : 237 - 246
  • [34] IRIDIUM ISOTOPE RATIO MEASUREMENTS BY NEGATIVE THERMAL IONIZATION MASS-SPECTROMETRY AND ATOMIC-WEIGHT OF IRIDIUM
    WALCZYK, T
    HEUMANN, KG
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 123 (02): : 139 - 147
  • [35] WALCZYK T, 1991, FRESEN J ANAL CHEM, V341, P357