Adaptive-optics ultrahigh-resolution optical coherence tomography

被引:309
作者
Hermann, B [1 ]
Fernández, EJ
Unterhuber, A
Sattmann, H
Fercher, AF
Drexler, W
Prieto, PM
Artal, P
机构
[1] Med Univ Vienna, Christian Doppler Lab, Dept Phys Med, Vienna, Austria
[2] Univ Murcia, Dept Fis, Lab Opt, Murcia, Spain
关键词
D O I
10.1364/OL.29.002142
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Merging of ultrahigh-resolution optical coherence tomography (UHR OCT) and adaptive optics (AO), resulting in high axial (3 mum) and improved transverse resolution (5-10 mum) is demonstrated for the first time to our knowledge in in vivo retinal imaging. A compact (300 mm X 300 mm) closed-loop AO system, based on a real-time Hartmann-Shack wave-front sensor operating at 30 Hz and a 37-actuator membrane deformable mirror, is interfaced to an UHR OCT system, based on a commercial OCT instrument, employing a compact Ti:sapphire laser with 130-nm bandwidth. Closed-loop correction of both ocular and system aberrations results in a residual uncorrected wave-front rms of 0.1 mum for a 3.68-mm pupil diameter. When this level of correction is achieved, OCT images are obtained under a static mirror configuration. By use of AO, an improvement of the transverse resolution of two to three times, compared with UHR OCT systems used so far, is obtained. A significant signal-to-noise ratio improvement of up to 9 dB in corrected compared with uncorrected OCT tomograms is also achieved. (C) 2004 Optical Society of America.
引用
收藏
页码:2142 / 2144
页数:3
相关论文
共 13 条
  • [1] HIGH-RESOLUTION IMAGING OF THE LIVING HUMAN FOVEA - MEASUREMENT OF THE INTERCENTER CONE DISTANCE BY SPECKLE INTERFEROMETRY
    ARTAL, P
    NAVARRO, R
    [J]. OPTICS LETTERS, 1989, 14 (20) : 1098 - 1100
  • [2] Compensation of corneal aberrations by the internal optics in the human eye
    Artal, Pablo
    Guirao, Antonio
    Berrio, Esther
    Williams, David R.
    [J]. JOURNAL OF VISION, 2001, 1 (01): : 1 - 8
  • [3] In vivo ultrahigh-resolution optical coherence tomography
    Drexler, W
    Morgner, U
    Kärtner, FX
    Pitris, C
    Boppart, SA
    Li, XD
    Ippen, EP
    Fujimoto, JG
    [J]. OPTICS LETTERS, 1999, 24 (17) : 1221 - 1223
  • [4] Ultrahigh-resolution ophthalmic optical coherence tomography
    Drexler, W
    Morgner, U
    Ghanta, RK
    Kärtner, FX
    Schuman, JS
    Fujimoto, JG
    [J]. NATURE MEDICINE, 2001, 7 (04) : 502 - 507
  • [5] Ultrahigh-resolution optical coherence tomography
    Drexler, W
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) : 47 - 74
  • [6] Membrane deformable mirror for adaptive optics:: performance limits in visual optics
    Fernández, EJ
    Artal, P
    [J]. OPTICS EXPRESS, 2003, 11 (09): : 1056 - 1069
  • [7] Closed-loop adaptive optics in the human eye
    Fernández, EJ
    Iglesias, I
    Artal, P
    [J]. OPTICS LETTERS, 2001, 26 (10) : 746 - 748
  • [8] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [9] Supernormal vision and high-resolution retinal imaging through adaptive optics
    Liang, JZ
    Williams, DR
    Miller, DT
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (11) : 2884 - 2892
  • [10] Coherence gating and adaptive optics in the eye
    Miller, DT
    Qu, JL
    Jonnal, RS
    Thorn, K
    [J]. COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VII, 2003, 4956 : 65 - 72