Cardiac cine imaging at 3 Tesla - Initial experience with a 32-element body-array coil

被引:14
作者
Fenchel, Michael
Deshpande, Vibhas S.
Nael, Kambiz
Finn, J. Paul
Miller, Stephan
Ruehm, Stefan
Laub, Gerhard
机构
[1] Univ Tubingen, Dept Diagnost Radiol, D-72076 Tubingen, Germany
[2] Univ Calif Los Angeles, Dept Radiol Sci, David Geffen Sch Med, Los Angeles, CA USA
[3] Siemens Med Solut, Malvern, PA USA
关键词
magnetic resonance; MR angiography; MRA; parallel imaging; GRAPPA; 3; Tesla;
D O I
10.1097/01.rli.0000223896.70095.49
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We sought to assess the feasibility of cardiac cine imaging and evaluate image quality at 3 T using a body-array coil with 32 coil elements. Materials and Methods: Eight healthy volunteers (3 men; median age 29 years) were examined on a 3-T magnetic resonance scanner (Magnetom Trio, Siemens Medical Solutions) using a 32-element phased-array coil (prototype from In vivo Corp.). Gradient-recalled-echo (GRE) cine (GRAPPAx3), GRE cine with tagging lines, steady-state-free-precession (SSFP) cine (GRAPPAx3 and x4), and SSFP cine (TSENSEx4 and x6) images were acquired in short-axis and 4-chamber view. Reference images with identical scan parameters were acquired using the total-imaging-matrix (Tim) coil system with a total of 12 coil elements. Images were assessed by 2 observers in a consensus reading with regard to image quality, noise and presence of artifacts. Furthermore, signal-to-noise values were determined in phantom measurements. Results: In phantom measurements signal-to-noise values were increased by 115-155% for the various cine sequences using the 32-element coil. Scoring of image quality yielded statistically significant increased image quality with the SSFP-GRAPPAx4, SSFP-TSENSEx4, and SSFP-TSENSEx6 sequence using the 32-element coil (P < 0.05). Similarly, scoring of image noise yielded a statistically significant lower noise rating with the SSFP-GRAPPAx4, GRE-GRAPPAx3, SSFP-TSENSEx4, and SSFP-TSENSEx6 sequence using the 32-element coil (P < 0.05). Conclusion: This study shows that cardiac cine imaging at 3 T using a 32-element body-array coil is feasible in healthy volunteers. Using a large number of coil elements with a favorable sensitivity profile supports faster image acquisition, with high diagnostic image quality even for high parallel imaging factors.
引用
收藏
页码:601 / 608
页数:8
相关论文
共 28 条
[1]  
Atalay MK, 2001, MAGNET RESON MED, V45, P341, DOI 10.1002/1522-2594(200102)45:2<341::AID-MRM1043>3.0.CO
[2]  
2-Q
[3]   Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency [J].
Deshpande, VS ;
Shea, SM ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) :803-809
[4]   Planimetry of mitral valve stenosis by magnetic resonance imaging [J].
Djavidani, B ;
Debl, K ;
Lenhart, M ;
Seitz, J ;
Paetzel, C ;
Schmid, FX ;
Nitz, WR ;
Feuerbach, S ;
Riegger, G ;
Luchner, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (12) :2048-2053
[5]   Comprehensive cardiac magnetic resonance imaging at 3.0 tesla - Feasibility and implications for clinical applications [J].
Gutberlet, M ;
Noeske, R ;
Schwinge, K ;
Freyhardt, P ;
Felix, R ;
Niendorf, T .
INVESTIGATIVE RADIOLOGY, 2006, 41 (02) :154-167
[6]   Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging:: comparison of 1.5 T vs. 3.0 T [J].
Gutberlet, M ;
Schwinge, K ;
Freyhardt, P ;
Spors, B ;
Grothoff, M ;
Denecke, T ;
Lüdemann, L ;
Noeske, R ;
Niendorf, T ;
Felix, R .
EUROPEAN RADIOLOGY, 2005, 15 (08) :1586-1597
[7]   Parallel acquisition techniques in cardiac cine magnetic resonance imaging using TrueFISP sequences: Comparison of image quality and artifacts [J].
Hunold, P ;
Maderwald, S ;
Ladd, ME ;
Jellus, V ;
Barkhausen, J .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (03) :506-511
[8]   Adaptive sensitivity encoding incorporating temporal filtering (TSENSE) [J].
Kellman, P ;
Epstein, FH ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) :846-852
[9]  
Kramer C M, 2000, Cardiol Rev, V8, P216, DOI 10.1097/00045415-200008040-00007
[10]   MR imaging evaluation of myocardial viability in the setting of equivocal SPECT results with 99mTc sestamibi [J].
Lee, VS ;
Resnick, D ;
Tiu, SS ;
Sanger, JJ ;
Nazzaro, CA ;
Israel, GM ;
Simonetti, OP .