Enhanced method performance due to a shorter chromatographic run-time in a liquid chromatography-tandem mass spectrometry assay for paclitaxel

被引:24
作者
Mortier, KA
Verstraete, AG
Zhang, GF
Lambert, WE
机构
[1] State Univ Ghent, Toxicol Lab, B-9000 Ghent, Belgium
[2] State Univ Ghent Hosp, Dept Biol Clin, B-9000 Ghent, Belgium
关键词
sensitivity; paclitaxel; docetaxel;
D O I
10.1016/j.chroma.2004.04.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography-tandem mass spectrometry (LC-MS-MS) is often performed in a high-throughput environment. Unfortunately, with atmospheric pressure ionization (API) techniques, shorter run-times or reduced sample clean-up often result in ion or matrix suppression, which can lead to erroneous results. The present work on the analysis of paclitaxel compares ion suppression, sensitivity and linearity of a high-throughput LC-MS-MS method (0.8 min run-time, method 13) to a method with increased separation (2.0 min run-time, method A). An atmospheric pressure chemical ionization (APCI) interface was used for both methods. The high-sample-throughput method uses an increased amount of organic solvent in the mobile phase (isocratic, 85% versus 70% of methanol) and a higher flow-rate (600 mul/min versus 400 mul/min). As a result, internal standard (docetaxel) and target analyte (paclitaxel) co-elute, close to, although separated from the solvent front. Ion suppression of both methods was evaluated by comparing pure standard to plasma and plasma containing a vehicle. Sensitivity and linearity were compared by injecting matrix matched calibration samples with both methods. Ion suppression by the vehicle Cremophor EL led to poor data quality for the standard method (A), while for the short method (13), ion suppression was compensated for by the co-eluting internal standard. The short method showed similar linearity but increased sensitivity by at least a factor five. This work provides a strategy to compensate for ion suppression without the use of labeled internal standards. In addition, a better sensitivity and a shorter run-time are noted. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:235 / 238
页数:4
相关论文
共 13 条
[1]   Measurement of paclitaxel in biological matrices: high-throughput liquid chromatographic-tandem mass spectrometric quantification of paclitaxel and metabolites in human and dog plasma [J].
Alexander, MS ;
Kiser, MM ;
Culley, T ;
Kern, JR ;
Dolan, JW ;
McChesney, JD ;
Zygmunt, J ;
Bannister, SJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (02) :253-261
[2]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.3.CO
[3]  
2-S
[4]   Quantitation of SR 27417 in human plasma using electrospray liquid chromatography tandem mass spectrometry: A study of ion suppression [J].
Buhrman, DL ;
Price, PI ;
Rudewicz, PJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (11) :1099-1105
[5]   Postcolumn introduction of an internal standard for quantitative LC-MS analysis [J].
Choi, BK ;
Gusev, AI ;
Hercules, DM .
ANALYTICAL CHEMISTRY, 1999, 71 (18) :4107-4110
[6]   Effect of the sample matrix on the determination of indinavir in human urine by HPLC with turbo ion spray tandem mass spectrometric detection [J].
Fu, I ;
Woolf, EJ ;
Matuszewski, BK .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (03) :347-357
[7]   Mechanistic investigation of ionization suppression in electrospray ionization [J].
King, R ;
Bonfiglio, R ;
Fernandez-Metzler, C ;
Miller-Stein, C ;
Olah, T .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (11) :942-950
[8]   Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3019-3030
[9]   Matrix effect in quantitative LC/MS/MS analyses of biological fluids: A method for determination of finasteride in human plasma at picogram per milliliter concentrations [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :882-889
[10]   Investigation of matrix effects in bioanalytical high-performance liquid chromatography/tandem mass spectrometric assays: application to drug discovery [J].
Mei, H ;
Hsieh, YS ;
Nardo, C ;
Xu, XY ;
Wang, SY ;
Ng, K ;
Korfmacher, WA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (01) :97-103