A simple algorithm improves mass accuracy to 50-100 ppm for delayed extraction linear matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

被引:10
作者
Hack, CA [1 ]
Benner, WH [1 ]
机构
[1] Lawrence Berkeley Natl, Berkeley, CA 94720 USA
关键词
D O I
10.1002/rcm.715
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple mathematical technique for improving mass calibration accuracy of linear delayed extraction matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (DE MALDI-TOFMS) spectra is presented. The method involves fitting a parabola to a plot of Deltam vs. mass data where Deltam is the difference between the theoretical mass of calibrants and the mass obtained from a linear relationship between the square root of m/z and ion time of flight. The quadratic equation that describes the parabola is then used to correct the mass of unknowns by subtracting the deviation predicted by the quadratic equation from measured data. By subtracting the value of the parabola at each mass from the calibrated data, the accuracy of mass data points can be improved by factors of 10 or more. This method produces highly similar results whether or not initial ion velocity is accounted for in the calibration equation; consequently, there is no need to depend on that uncertain parameter when using the quadratic correction. This method can be used to correct the internally calibrated masses of protein digest peaks. The effect of nitrocellulose as a matrix additive is also briefly discussed, and it is shown that using nitrocellulose as an additive to the alpha-cyano-4-hydroxycinnamic acid (alphaCHCA) matrix does not significantly change initial ion velocity but does change the average position of ions relative to the sample electrode at the instant the extraction voltage is applied. Published in 2002 by John Wiley Sons, Ltd.
引用
收藏
页码:1304 / 1312
页数:9
相关论文
共 17 条
[1]   Evaluation of the variables that affect resolution in delayed extraction MALDI-TOF [J].
Barbacci, DC ;
Edmondson, RD ;
Russell, DH .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 165 :221-235
[2]   IDENTIFICATION OF DENATURED DOUBLE-STRANDED DNA BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY [J].
BENNER, WH ;
HORN, D ;
KATZ, J ;
JAKLEVIC, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (06) :537-540
[3]   Improvements in protein identification by MALDI-TOF-MS peptide mapping [J].
Egelhofer, V ;
Büssow, K ;
Luebbert, C ;
Lehrach, H ;
Nordhoff, E .
ANALYTICAL CHEMISTRY, 2000, 72 (13) :2741-2750
[4]  
Glückmann M, 1999, J MASS SPECTROM, V34, P467, DOI 10.1002/(SICI)1096-9888(199905)34:5<467::AID-JMS809>3.0.CO
[5]  
2-8
[6]  
Jensen ON, 1996, RAPID COMMUN MASS SP, V10, P1371, DOI 10.1002/(SICI)1097-0231(199608)10:11<1371::AID-RCM682>3.3.CO
[7]  
2-X
[8]   On the initial velocity of ions generated by matrix-assisted laser desorption ionization and its effect on the calibration of delayed extraction time-of-flight mass spectra [J].
Juhasz, P ;
Vestal, ML ;
Martin, SA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (03) :209-217
[9]  
Karas M, 2000, J MASS SPECTROM, V35, P1, DOI 10.1002/(SICI)1096-9888(200001)35:1<1::AID-JMS904>3.0.CO
[10]  
2-0