Inadequate polyethylene thickness and osteolysis in cementless hip arthroplasty

被引:18
作者
Learmonth, ID [1 ]
Hussell, JG [1 ]
Smith, EJ [1 ]
机构
[1] UNIV BRISTOL,DEPT ORTHOPAED SURG,BRISTOL,AVON,ENGLAND
关键词
cementless hip arthroplasty; osteolysis; polyethylene wear; WEAR;
D O I
10.1016/S0883-5403(97)90027-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
A matched series of Porous Coated Anatomic (PCA, Howmedica, Rutherford, NJ) cementless hip arthroplasties comparing a 26-mm with a 32-mm head were reviewed. The 26-mm head was used in 63 hips of 56 patients (group 1), and the 32-mm head was inserted into 97 hips of 90 patients (group 2). The two groups were matched for age, sex, and primary diagnosis. The postoperative follow-up period ranged from 3 to 6.9 years (mean, 4.2 years) in group 1, compared with 3 to 7.9 years (mean, 4.5 years) for group 2. The mean clinical scores for pain, movement, and function were similar for the two groups. Erosive osteolytic lesions were encountered in 25.7% of the group 2 hips but in none of the group 1 cases. These lesions were not seen before 3 years after surgery and were present in Gruen zone 7 of all involved hips, although in two patients they were also noted in zone 1. Osteolysis was encountered only with the 32-mm head where the outer diameter of the metal-backed cup was 52 mm or less. Therefore, inadequate polyethylene thickness, rather than head size, is implicated as the cause of plastic particle-mediated osteolysis.
引用
收藏
页码:305 / 309
页数:5
相关论文
共 14 条
[1]
Bartel D L, 1983, Hip, P229
[2]
POLYETHYLENE WEAR IN CEMENTED METAL-BACKED ACETABULAR CUPS [J].
CATES, HE ;
FARIS, PM ;
KEATING, EM ;
RITTER, MA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :249-253
[3]
OPTIMUM SIZE OF PROSTHETIC HEADS IN RELATION TO WEAR OF PLASTIC SOCKETS IN TOTAL REPLACEMENT OF HIP [J].
CHARNLEY, J ;
KAMANGAR, A ;
LONGFIELD, MD .
MEDICAL & BIOLOGICAL ENGINEERING, 1969, 7 (01) :31-+
[4]
Charnley JJLfaotht, 1979, Numerical grading of clinical results, P20
[5]
COLLIER JP, 1990, CLIN ORTHOP RELAT R, V261, P107
[6]
DELEE JG, 1976, CLIN ORTHOPAEDICS, V121, P20
[7]
Jones LC., 1987, Clin Orthop, V225, P192
[8]
LEARMONTH ID, 1992, J BONE JOINT SURG BR, V72, P980
[9]
POLYETHYLENE FAILURE IN 2 TOTAL KNEES - WEAR OF THIN, METAL-BACKED PCA TIBIAL COMPONENTS [J].
LINDSTRAND, A ;
RYD, L ;
STENSTROM, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1990, 61 (06) :575-577
[10]
EFFECT OF FEMORAL-HEAD SIZE ON WEAR OF THE POLYETHYLENE ACETABULAR COMPONENT [J].
LIVERMORE, J ;
ILSTRUP, D ;
MORREY, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (04) :518-528