Comparison and interconversion of the two most common frequency-to-mass calibration functions for Fourier transform ion cyclotron resonance mass spectrometry

被引:204
作者
Shi, SDH
Drader, JJ
Freitas, MA
Hendrickson, CL
Marshall, AG [1 ]
机构
[1] Florida State Univ, Dept Chem, Tallahassee, FL 32310 USA
[2] Florida State Univ, Natl High Magnet Field Lab, Ctr Interdisciplinary Magnet Resonance, Tallahassee, FL 32310 USA
关键词
ion cyclotron resonance; Fourier transform mass spectrometry; penning trap;
D O I
10.1016/S1387-3806(99)00226-2
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
In a perfect three-dimensional axial quadrupolar electrostatic potential field, Ledford et al. showed that the frequency-to-mass calibration relation m/z = A(L)/v + B-L/v(2) is valid for ions of any mass-to-charge ratio, m/z < (m/z)(critical) = e B(0)(2)a(2)/4V(trap)alpha, in which v is the "reduced" (observed) ion cyclotron frequency, e is the electronic (elementary) charge, z is the number of elementary charges per ion, B-0, is magnetic field induction, a is a characteristic trap dimension, v(trap) is the potential applied to each trap endcap, alpha is a constant determined by the trap geometrical configuration, and A(L) and B-L are constants that are determined by fitting experimental ion cyclotron resonance (ICR) frequencies for ions of at least two known masses in a Fourier transform ICR (FT-ICR) mass spectrum. In the further limit that m/z much less than (m/z)(critical), Francl et al. obtained a different frequency-to-mass relation m/z = A(F)/(B-F + v). Here, we rederive both frequency-to-mass relations to derive a simple conversion between A(L) and B-L, versus A(F) and B-F (e.g, for comparing calibrated FT-ICR mass spectral data from different vendors). For accurate mass measurement, the conversion introduces a small error (a few parts per billion) that can usually be neglected. More important, by applying both calibration equations to the same experimental time-domain data, we find that mass accuracy resulting from the two calibration functions (or their interconversion) is indistinguishable, because Ledford et al,'s validity criterion, m/z < 0.001 (m/z)(critical), is generally satisfied for modern high-field instruments with optimized cell geometry. Interestingly, a small difference may result when different forms of the same calibration function are employed, presumably due to different roundoff errors in the calculation. (C) 2000 Elsevier Science B.V.
引用
收藏
页码:591 / 598
页数:8
相关论文
共 24 条
[1]  
ALLEMANN M, 1981, CHEM PHYS LETT, V84, P547, DOI 10.1016/0009-2614(81)80405-8
[2]   LINE-NARROWING BY MACROSCOPIC MOTION [J].
BLOCH, F .
PHYSICAL REVIEW, 1954, 94 (02) :496-497
[3]   GEONIUM THEORY - PHYSICS OF A SINGLE ELECTRON OR ION IN A PENNING TRAP [J].
BROWN, LS ;
GABRIELSE, G .
REVIEWS OF MODERN PHYSICS, 1986, 58 (01) :233-311
[4]   MODELING COULOMB EFFECTS IN FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY BY CHARGED DISKS AND CHARGED CYLINDERS [J].
CHEN, SP ;
COMISAROW, MB .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (01) :1-3
[5]   EXPERIMENTAL-DETERMINATION OF THE EFFECTS OF SPACE-CHARGE ON ION-CYCLOTRON RESONANCE FREQUENCIES [J].
FRANCL, TJ ;
SHERMAN, MG ;
HUNTER, RL ;
LOCKE, MJ ;
BOWERS, WD ;
MCIVER, RT .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 54 (1-2) :189-199
[6]   ELIMINATION OF FREQUENCY DRIFT FROM FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTRA BY DIGITAL QUADRATURE HETERODYNING - ULTRAHIGH MASS RESOLVING POWER FOR LASER-DESORBED MOLECULES [J].
GUAN, SH ;
WAHL, MC ;
MARSHALL, AG .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3647-3653
[7]   ION TRAPS FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY - PRINCIPLES AND DESIGN OF GEOMETRIC AND ELECTRIC CONFIGURATIONS [J].
GUAN, SH ;
MARSHALL, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1995, 146 :261-296
[8]   MASS-DEPENDENT Z-EXCITATION OF IONS IN CUBIC TRAPS USED IN FTMS [J].
HUANG, SK ;
REMPEL, DL ;
GROSS, ML .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 72 (1-2) :15-31
[9]   Linearity and quadrupolarity of tetragonal and cylindrical penning traps of arbitrary length-to-width ratio [J].
Jackson, GS ;
Canterbury, JD ;
Guan, SH ;
Marshall, AG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (03) :283-293
[10]   Matrix-shimmed ion cyclotron resonance ion trap simultaneously optimized for excitation, detection, quadrupolar axialization, and trapping [J].
Jackson, GS ;
White, FM ;
Guan, SH ;
Marshall, AG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (08) :759-769