Validation of the coupling of magnetic resonance imaging velocity measurements with computational fluid dynamics in a U bend

被引:24
作者
Glor, FP
Westenberg, JJM
Vierendeels, J
Danilouchkine, M
Verdonck, P
机构
[1] Univ Ghent, Hydraul Lab, Inst Biomed Technol, B-9000 Ghent, Belgium
[2] Leiden Univ, Med Ctr, Div Imaging Proc, Leiden, Netherlands
[3] Univ Ghent, Fluid Mech Lab, Dept Flow Heat & Combust Mech, B-9000 Ghent, Belgium
关键词
cine magnetic resonance imaging; computational fluid dynamics; inflow boundary condition; U bend;
D O I
10.1046/j.1525-1594.2002.07085.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic resonance imaging (MRI) can be used in vivo in combination with computational fluid dynamics (CFD) to derive velocity profiles in space and time and accordingly, pressure drop and wall shear stress distribution in natural or artificial vessel segments. These hemodynamic data are difficult or impossible to acquire directly in vivo. Therefore, research has been performed combining MRI and CFD for flow simulations in flow phantoms, such as bends or anastomoses, and even in human vessels such as the aorta, the carotid, and the abdominal bifurcation. There is, however, no unanimity concerning the use of MRI velocity measurements as input for the inflow boundary condition of a CFD simulation. In this study, different input possibilities for the inflow boundary conditions are compared. MRI measurements of steady and pulsatile flow were performed on a U bend phantom, representing the aorta geometry. PAMFLOW (ESI Software, Krimpen aan den Ussel, The Netherlands), an industrial CFD software package, was used to solve the Navier-Stokes equations for incompressible flow. Three main parameters were found to influence the choice of an inflow boundary condition type. First, the flow rate through a vessel should be exact, since it proves to be a determining factor for the accuracy of the velocity profile. The other decisive parameters are the physiology of the flow profile and the required computer processing unit time. Our comparative study indicates that the best way to handle an inflow boundary condition is to use the velocities measured by MRI at the inflow plane as being fixed velocities. However, before using these MRI velocity data, they first should be corrected for the partial volume effect by filtering and second scaled in order to obtain the correct flow rate. This implies that a reliable flow rate measurement absolutely is needed for CFD calculations based on MRI velocity measurements.
引用
收藏
页码:622 / 635
页数:14
相关论文
共 61 条
[1]   LASER ANEMOMETER STUDY OF FLOW DEVELOPMENT IN CURVED CIRCULAR PIPES [J].
AGRAWAL, Y ;
TALBOT, L ;
GONG, K .
JOURNAL OF FLUID MECHANICS, 1978, 85 (APR) :497-518
[2]   Air flow and particle deposition patterns in bronchial airway bifurcations: The effect of different CFD models and bifurcation geometries [J].
Balashazy, I ;
Heistracher, T ;
Hofmann, W .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1996, 9 (03) :287-301
[3]   Hemodynamics in the carotid artery bifurcation: a comparison between numerical simulations and in vitro MRI measurements [J].
Botnar, R ;
Rappitsch, G ;
Scheidegger, MB ;
Liepsch, D ;
Perktold, K ;
Boesiger, P .
JOURNAL OF BIOMECHANICS, 2000, 33 (02) :137-144
[4]   STEADY ENTRY FLOW IN A CURVED PIPE [J].
BOVENDEERD, PHM ;
VANSTEENHOVEN, AA ;
VANDEVOSSE, FN ;
VOSSERS, G .
JOURNAL OF FLUID MECHANICS, 1987, 177 :233-246
[5]   New methods for computational fluid dynamics modeling of carotid artery from magnetic resonance angiography [J].
Cebral, JR ;
Yim, PJ ;
Löhner, R ;
Soto, O ;
Marcos, H ;
Choyke, PL .
MEDICAL IMAGING 2001: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2001, 4321 :177-187
[6]   From medical images to anatomically accurate finite element grids [J].
Cebral, JR ;
Löhner, R .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2001, 51 (08) :985-1008
[7]   Quantification of mitral regurgitation with MR phase-velocity mapping using a control volume method [J].
Chatzimavroudis, GP ;
Oshinski, JN ;
Pettigrew, RI ;
Walker, PG ;
Franch, RH ;
Yoganathan, AP .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03) :577-582
[8]   Evaluation of the precision of magnetic resonance phase velocity mapping for blood flow measurements [J].
Chatzimavroudis, GP ;
Oshinski, JN ;
Franch, RH ;
Walker, PG ;
Yoganathan, AP ;
Pettigrew, RI .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2001, 3 (01) :11-19
[9]   EXPERIMENTAL-STUDY OF WALL SHEAR RATES IN THE ENTRY REGION OF A CURVED TUBE [J].
CHOI, US ;
TALBOT, L ;
CORNET, I .
JOURNAL OF FLUID MECHANICS, 1979, 93 (AUG) :465-489
[10]   DEAN VORTICES IN CURVED TUBE FLOW .5. 3-D MRI AND NUMERICAL-ANALYSIS OF THE VELOCITY-FIELD [J].
CHUNG, KY ;
BELFORT, G ;
EDELSTEIN, WA ;
LI, XM .
AICHE JOURNAL, 1993, 39 (10) :1592-1602