Generation of arbitrary monotonic concentration profiles by a serial dilution microfluidic network composed of microchannels with a high fluidic-resistance ratio

被引:52
作者
Hattori, Koji [1 ]
Sugiura, Shinji [1 ]
Kanamori, Toshiyuki [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Res Ctr Adv Bion, Tsukuba, Ibaraki 3058565, Japan
关键词
CANCER CELL CHEMOTAXIS; IN-VITRO CYTOTOXICITY; CONCENTRATION GRADIENTS; NEUTROPHIL CHEMOTAXIS; DEVICE; ARRAY; DOXORUBICIN; PARALLEL; SYSTEMS; FORMULATION;
D O I
10.1039/b816995k
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports a serial dilution microfluidic network composed of microchannels with a high fluidic-resistance ratio for generating linear concentration profiles as well as logarithmic concentration profiles spanning 3 and 6 orders of magnitude. The microfluidic networks were composed of thin fluidic-resistance microchannels with 160 to 730 mu m(2) cross-sectional areas and thick diffusion-mixing microchannels with 3,600 to 17,000 mu m(2) cross-sectional areas, and were fabricated from polydimethylsiloxane by multilayer photolithography and replica molding. We proposed a design algorithm of the microfluidic network for an arbitrary monotonic concentration profile by means of a hydrodynamic calculation. Because of the high fluidic-resistance ratio of the fluidic-resistance microchannels to the diffusion-mixing microchannels, appropriate geometry and dimensions of the fluidic-resistance microchannels allowed us to obtain desired concentration profiles. The fabricated microfluidic network was compact, occupying a 8 x 18 to 21.0 x 13.5 mm(2) area on the microchip. Both the linear and the logarithmic concentration profiles were successfully generated with the error less than 15% for the linear concentration profile, 22% and 35% for the logarithmic concentration profiles of 3 and 6 orders of magnitude, respectively. The generated linear concentration profiles of the small molecule, calcein, were independent of the flow rate within the range of 0.009 to 0.23 mu L/min. The concentration profiles of the large molecules, dextrans, depended on the flow rate and molecular weight. The required residence time of large molecules in the diffusion-mixing microchannel was correlated with dimensionless diffusion time, Fick number, and was discussed based on the scaling law. These compact, stable serial dilution microfluidic networks are expected to be applied to various integrated on-chip analyses.
引用
收藏
页码:1763 / 1772
页数:10
相关论文
共 48 条
[1]   Compact microfluidic structures for generating spatial and temporal gradients [J].
Amarie, Dragos ;
Glazier, James A. ;
Jacobson, Stephen C. .
ANALYTICAL CHEMISTRY, 2007, 79 (24) :9471-9477
[2]   In vitro cytotoxicity of (-)-catechin gallate, a minor polyphenol in green tea [J].
Babich, H. ;
Zuckerbraun, H. L. ;
Weinerman, S. M. .
TOXICOLOGY LETTERS, 2007, 171 (03) :171-180
[3]   Serial dilution microchip for cytotoxicity test [J].
Bang, H ;
Lim, SH ;
Lee, YK ;
Chung, S ;
Chung, C ;
Han, DC ;
Chang, JK .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (08) :1165-1170
[4]   Fabrication of gradient hydrogels using a microfluidics/photopolymerization process [J].
Burdick, JA ;
Khademhosseini, A ;
Langer, R .
LANGMUIR, 2004, 20 (13) :5153-5156
[5]   Generation of complex concentration profiles in microchannels in a logarithmically small number of steps [J].
Campbell, Kyle ;
Groisman, Alex .
LAB ON A CHIP, 2007, 7 (02) :264-272
[6]   Synthesis, characterization and in vitro cytotoxicity studies of a macromolecular conjugate of paclitaxel bearing oxytocin as targeting moiety [J].
Cavallaro, Gennara ;
Maniscalco, Laura ;
Campisi, Monica ;
Schillaci, Domenico ;
Giammona, Gaetano .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2007, 66 (02) :182-192
[7]   Human neural stem cell growth and differentiation in a gradient-generating microfluidic device [J].
Chung, BG ;
Flanagan, LA ;
Rhee, SW ;
Schwartz, PH ;
Lee, AP ;
Monuki, ES ;
Jeon, NL .
LAB ON A CHIP, 2005, 5 (04) :401-406
[8]   Prototyping of masks, masters, and stamps/molds for soft lithography using an office printer and photographic reduction [J].
Deng, T ;
Wu, HK ;
Brittain, ST ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3176-3180
[9]   Generation of gradients having complex shapes using microfluidic networks [J].
Dertinger, SKW ;
Chiu, DT ;
Jeon, NL ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1240-1246
[10]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984