Spinal cage retrieval and assessment of biologic response

被引:7
作者
Brodke, DS
Willie, BM
Maaranen, TA
Bloebaum, RD
机构
[1] Univ Utah, Sch Med, Dept Orthoped, Salt Lake City, UT 84132 USA
[2] Salt Lake City Vet Affairs Hlth Care Syst, Bone & Joint Res Lab, Salt Lake City, UT USA
来源
JOURNAL OF SPINAL DISORDERS & TECHNIQUES | 2002年 / 15卷 / 03期
关键词
spine; interbody fusion device; allograft; cage; pseudoarthrosis; corpectomy;
D O I
10.1097/00024720-200206000-00007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Implant retrieval programs have been effective in understanding implant failure and biomaterial compatibility in joint arthroplasty; however, its application has not been extended extensively to the assessment of spinal constructs and implants. The objective of this study is to determine the efficacy of implant retrieval analysis as a standard for the assessment of explanted spinal implants. The limitations of clinical radiographic assessment of fusion through metal interbody devices are also identified. The implant analysis protocol is shown through a case report of a titanium mesh spinal fusion cage retrieved from a 54-year-old woman who had a pseudoarthrosis at the T12 cage interface. The implant analysis techniques include backscattered electron imaging, high-resolution contact radiography, histology, and fluorochrome analysis. Ail implant retrieval analysis program similar to the one discussed in the presented case study will enable an accurate assessment of outcomes of these commonly used implants and will guide future development.
引用
收藏
页码:206 / 212
页数:7
相关论文
共 43 条
[1]
Bloebaum R D, 1990, J Biomater Appl, V5, P56
[2]
Postmortem analysis of consecutively retrieved asymmetric porous-coated tibial components [J].
Bloebaum, RD ;
Bachus, KN ;
Jensen, JW ;
Hofmann, AA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (08) :920-929
[3]
Postmortem analysis of bone growth into porous-coated acetabular components [J].
Bloebaum, RD ;
Mihalopoulus, NL ;
Jensen, JW ;
Dorr, LD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07) :1013-1022
[4]
Porous-coated metal-backed patellar components in total knee replacement - A postmortem retrieval analysis [J].
Bloebaum, RD ;
Bachus, KN ;
Jensen, JW ;
Scott, DF ;
Hofmann, AA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (04) :518-528
[5]
Determining mineral content variations in bone using backscattered electron imaging [J].
Bloebaum, RD ;
Skedros, JG ;
Vajda, EG ;
Bachus, KN ;
Constantz, BR .
BONE, 1997, 20 (05) :485-490
[6]
BLOEBAUM RD, 1989, J HISTOTECHNOL, V12, P307
[7]
MINERAL APPOSITION RATES OF HUMAN CANCELLOUS BONE AT THE INTERFACE OF POROUS-COATED IMPLANTS [J].
BLOEBAUM, RD ;
BACHUS, KN ;
MOMBERGER, NG ;
HOFMANN, AA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (05) :537-544
[8]
BLOEBAUM RD, 1991, CLIN ORTHOP RELAT R, P179
[9]
BLOEBAUM RD, 1991, CLIN ORTHOP RELAT R, P97
[10]
BLOEBAUM RD, 1995, T ORTHOP RES SOC, V20, P776