Evaluation of fast gas chromatography and gas chromatography-mass spectrometry in the analysis of lipids

被引:56
作者
Mondello, L
Casilli, A
Tranchida, PQ
Costa, R
Chiofalo, B
Dugo, P
Dugo, G
机构
[1] Univ Messina, Fac Farm, Dipartimento Farmaco Chim, I-98168 Messina, Italy
[2] Univ Messina, Dip Mo Bi Fi PA, Sez Zootecn, I-98168 Messina, Italy
[3] Univ Messina, Fac Sci MM FF NN, Dipartimento Chim Organ & Biol, I-98165 Messina, Italy
关键词
gas chromatography; fast; comprehensive two-dimensional; lipids; fatty acid methyl esters;
D O I
10.1016/j.chroma.2004.02.058
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fast and conventional gas chromatography (GC) techniques were applied to nine different lipidic matrices (butter, lard, tallow, and peanut, corn, sunflower, soya, olive, menhaden oils). Simultaneous methylic transesterification was performed on all samples prior to GC analysis. Several practical aspects concerning high speed analysis were investigated, such as the great increase in linear velocity, the use of fast temperature ramps, column sample capacity and detection systems. Analytical results showed certain losses in resolution, balanced by a consistent reduction in analysis time. The actual time savings were variable (60-70 min) as they were dependent on the complexity of the sample while the speed enhancement factor was equal to 10.5. Peak identification was achieved by means of different information sources, such as fast GC-mass spectrometry (MS), linear retention indices and comprehensive two-dimensional (2D) gas chromatography group patterns. The method developed was shown to be applicable in routine applications on complex natural samples. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:237 / 247
页数:11
相关论文
共 31 条
[11]  
Golay M.J.E., 1958, GAS CHROMATOGRAPHY
[12]  
Hinshaw JV, 2002, LC GC EUR, V15, P152
[13]   Dietetic guidelines: diet in secondary prevention of cardiovascular disease [J].
Hooper, L .
JOURNAL OF HUMAN NUTRITION AND DIETETICS, 2001, 14 (04) :297-305
[14]   HIGH-SPEED GAS-CHROMATOGRAPHY USING SIMULTANEOUS TEMPERATURE-GRADIENTS IN BOTH TIME AND DISTANCE ALONG NARROW-BORE CAPILLARY COLUMNS [J].
JAIN, V ;
PHILLIPS, JB .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1995, 33 (11) :601-605
[15]   Practical fast gas chromatography:: methods, instrumentation and applications [J].
Korytár, P ;
Janssen, HG ;
Matisová, E ;
Brinkman, UAT .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (9-10) :558-572
[16]   Practical approaches to fast gas chromatography-mass spectrometry [J].
Mastovská, K ;
Lehotay, SJ .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :153-180
[17]   Fast gas chromatography and its use in trace analysis [J].
Matisová, E ;
Dömötörová, M .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :199-221
[18]  
McNair HM, 2000, J MICROCOLUMN SEP, V12, P351, DOI 10.1002/1520-667X(2000)12:6<351::AID-MCS3>3.0.CO
[19]  
2-Y
[20]   Detailed analysis and group-type separation of natural fats and oils using comprehensive two-dimensional gas chromatography [J].
Mondello, L ;
Casilli, A ;
Tranchida, PQ ;
Dugo, P ;
Dugo, G .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1019 (1-2) :187-196