Applicator reconstruction in MRI 3D image-based dose planning of brachytherapy for cervical cancer

被引:100
作者
Haack, Soren [1 ]
Nielsen, Soren Kynde [2 ,3 ]
Lindegaard, Jacob Christian [4 ]
Gelineck, John
Tanderup, Kari [3 ]
机构
[1] Aarhus Univ Hosp, Dept Biomed Engn, DK-8200 Aarhus N, Denmark
[2] Aarhus Univ Hosp, Dept Oncol, DK-8200 Aarhus N, Denmark
[3] Aarhus Univ Hosp, Dept Med Phys, DK-8200 Aarhus N, Denmark
[4] Aarhus Univ Hosp, Dept Radiol, DK-8200 Aarhus N, Denmark
关键词
Brachytherapy; Applicator reconstruction; MRI; Copper sulphate; INTERSTITIAL BRACHYTHERAPY; COMBINED INTRACAVITARY; VOLUME PARAMETERS; VIENNA APPLICATOR; ARTIFACTS; RECOMMENDATIONS; SUSCEPTIBILITY; IMPACT; TERMS; SEED;
D O I
10.1016/j.radonc.2008.09.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To elaborate a method for applicator reconstruction for MRI-based brachytherapy for cervical cancer. Materials and methods: Custom-made plastic catheters with a copper sulphate solution were made for insertion in the Source channels of MR-CT compatible applicators: plastic and titanium tandem ring applicators, and titanium needles. The applicators were CT and MR scanned in a phantom for accurate 3D assessment of applicator visibility and geometry. A reconstruction method was developed and evaluated in 19 patient MR examinations with ring applicator (plastic: 14, titanium: 5). MR applicator reconstruction uncertainties related to inter-observer variation were evaluated. Results: The catheters were visible in the plastic applicator on T1-weighted images in phantom and in 14/14 clinical applications. On T2-weighted images, the catheters appeared weaker but Still visible in phantom and in 13/14 MR clinical applications. In the titanium applicator, the catheters Could not be separated from the artifacts from the applicator itself. However, these artifacts could be used to localize both titanium ring applicator (5/5 clinical applications) and needles (6/6 clinical applications). Standard deviations of inter-observer differences were below 2 mm in all directions. Conclusion: 3D applicator reconstruction based on MR imaging Could be performed for plastic and titanium applicators. Plastic applicators proved well to be suited for MRI-based reconstruction. For improved practicability of titanium applicator reconstruction, development of MR applicator markets is essential. Reconstruction of titanium applicator and needles at 1.5 T MR requires geometric evaluations in phantoms before using the applicator in patients. (C) 2008 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 91 (2009) 187-193
引用
收藏
页码:187 / 193
页数:7
相关论文
共 19 条
[1]   MR-IMAGING ARTIFACTS THAT SIMULATE DISEASE - HOW TO RECOGNIZE AND ELIMINATE THEM [J].
ARENA, L ;
MOREHOUSE, HT ;
SAFIR, J .
RADIOGRAPHICS, 1995, 15 (06) :1373-1394
[2]   Accuracy of seed reconstruction in prostate postplanning studied with a CT- and MRI-compatible phantom [J].
De Brabandere, Marisol ;
Kirisits, Christian ;
Peeters, Ronald ;
Haustermans, Karin ;
Van den Heuvel, Frank .
RADIOTHERAPY AND ONCOLOGY, 2006, 79 (02) :190-197
[3]   Systematic evaluation of MRI findings in different stages of treatment of cervical cancer:: Potential of MRI on delineation of target, pathoanatomic structures, and organs at risk [J].
Dimopoulos, JCA ;
Schard, G ;
Berger, D ;
Lang, S ;
Goldner, G ;
Helbich, T ;
Pötter, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (05) :1380-1388
[4]   The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer:: Clinical feasibility and preliminary results [J].
Dimopoulos, Johannes C. A. ;
Kirisits, Christian ;
Petric, Primoz ;
Georg, Petra ;
Lang, Stefan ;
Berger, Daniel ;
Poetter, Richard .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (01) :83-90
[5]   Metallic artefacts in MR imaging: Effects of main field orientation and strength [J].
Guermazi, A ;
Miaux, Y ;
Zaim, S ;
Peterfy, CG ;
White, D ;
Genant, HK .
CLINICAL RADIOLOGY, 2003, 58 (04) :322-328
[6]   Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group* (I):: concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV [J].
Haie-Meder, C ;
Pötter, R ;
Van Limbergen, E ;
Briot, E ;
De Brabandere, M ;
Dimopoulos, J ;
Dumas, I ;
Hellebust, TP ;
Kirisits, C ;
Lang, SF ;
Muschitz, S ;
Nevinson, J ;
Nulens, A ;
Petrow, P ;
Wachter-Gerstner, N .
RADIOTHERAPY AND ONCOLOGY, 2005, 74 (03) :235-245
[7]   Reconstruction of a ring applicator using CT imaging: impact of the reconstruction method and applicator orientation [J].
Hellebust, Taran Paulsen ;
Tanderup, Kari ;
Bergstrand, Eva Stabell ;
Knutsen, Bjorn Helge ;
Roislien, Jo ;
Olsen, Dag Rune .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (16) :4893-4904
[8]  
Kirisits C, 2007, RADIOTHER ONCOL, V84, pS14
[9]   The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer:: Design, application, treatment planning, and dosimetric results [J].
Kirisits, C ;
Lang, S ;
Dimopoulos, J ;
Berger, D ;
Georg, D ;
Pötter, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02) :624-630
[10]   Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancer [J].
Kirisits, C ;
Pötter, R ;
Lang, S ;
Dimopoulos, J ;
Wachter-Gerstner, N ;
Georg, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (03) :901-911