Alternans of blood pressure and heart rate in dilated cardiomyopathy

被引:13
作者
Leder, U
Pohl, HP
Baier, V
Baumert, M
Liehr, M
Haueisen, J
Voss, A
Figulla, HR
机构
[1] Univ Jena, Innere Med Klin 3, D-6900 Jena, Germany
[2] Fachhsch Jena, FB Med Tech, Jena, Germany
[3] Univ Jena, Biomagnet Zentrum, D-6900 Jena, Germany
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2002年 / 25卷 / 09期
关键词
alternans; dilated cardiomyopathy; heart failure; heart rate variability; blood pressure variability;
D O I
10.1046/j.1460-9592.2002.01307.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Impaired myocardial performance is known to be associated with electrical and mechanical beat-to-beat alternans phenomena. The alternans in blood pressure and heart rate and their interdependency in idiopathic dilated cardiomyopathy (IDC) were studied. The arterial blood pressure and the electrocardiograph (ECG) were continuously recorded in 22 patients suffering from IDC (age 49 +/- 13 years, ejection fraction 0.33 +/- 0.13, left ventricular diameter of 67 +/- 8 mm) and in 21 healthy controls (age 52 +/- 15 years), The beat-to-beat variations of the interbeat intervals (IBI) and of the blood pressure amplitudes (AMP) were measured. An alternans beat was defined as a beat preceded and followed by beats that had higher or lower values in the respective modality. The percentages of singular and repetitive alternans patterns, and the interdependency of the alternans patterns in AMP and IBI were assessed. The study found significantly more singular and repetitive alternans patterns in the IDC group compared to the control group both in the analysis of AMP and IBI (singular alternans in IBI: 55 +/- 11 vs 47 +/- 7%, P < 0.01; singular alternans in AMP: 61 +/- 15 vs 45 +/- 6%, P < 0.01; triple alternans in IBI: 29 +/- 18 vs 16 +/- 9%, P < 0.01; triple alternans in AMP: 34 24 vs 12 7%, P < 0.01). The amplitudes of the AMP alternans patterns were higher in IDC compared to controls (9 +/- 7 vs 4 +/- 2% of AMP, P = 0.01) whereas they did not differ in IBI. The correlation analysis revealed a significant interdependency of the alternans pattern in IBI and AMP in 18 of 22 IDC patients and in 12 of 21 controls (r = 0.50 +/- 0.21 [IDC]; r = 0.26 +/- 0.05 [controls]). The slope of the linear regression (DeltaAMP vs DeltaIBI) was steeper in the IDC group compared to the control group (62 +/- 50 vs 20 +/- 22 mmHg/s, P < 0,01). The percentages of alternans patterns appearing in IBI and AMP were positively correlated to the left ventricular diameter (r = 0.70 in the IBI, and r = 0.30 in the AMP), The blood pressure amplitude and the heart rate did not differ between the two groups. Patients suffering from IDC have a higher prevalence, stability, amplitude, and interdependency of alternans patterns in IBI and AMP compared to the control group. The amount of alternans patterns indicates the stage of disease. The alternans analysis may have impact on the functional assessment of patients suffering from heart failure.
引用
收藏
页码:1307 / 1314
页数:8
相关论文
共 19 条
[1]  
Ando S, 1997, CIRCULATION, V95, P316
[2]   HEART-RATE ALTERNANS [J].
BINKLEY, PF ;
EATON, GM ;
NUNZIATA, E ;
KHOT, U ;
CODY, RJ .
ANNALS OF INTERNAL MEDICINE, 1995, 122 (02) :115-117
[3]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[4]   POSTEXTRASYSTOLIC PULSUS ALTERNANS AND HEART-RATE [J].
CARLSON, CJ ;
RAPAPORT, E .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 246 (02) :H245-H249
[5]   AN EVALUATION OF PULSUS ALTERNANS IN CLOSED-CHEST DOGS [J].
FREEMAN, GL ;
WIDMAN, LE ;
CAMPBELL, JM ;
COLSTON, JT .
AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 262 (01) :H278-H284
[6]   STUDIES ON STARLINGS LAW OF HEART .4. RELATIONSHIPS BETWEEN LEFT VENTRICULAR END-DIASTOLIC VOLUME AND STROKE VOLUME IN MAN WITH OBSERVATIONS ON MECHANISM OF PULSUS ALTERNANS [J].
GLEASON, WL ;
BRAUNWALD, E .
CIRCULATION, 1962, 25 (05) :841-+
[7]   Accuracy and reliability of noninvasive continuous finger blood pressure measurement in critically ill patients [J].
Hirschl, MM ;
Binder, M ;
Herkner, H ;
Bur, A ;
Brunner, M ;
Seidler, D ;
Stuhlinger, HG ;
Laggner, AN .
CRITICAL CARE MEDICINE, 1996, 24 (10) :1684-1689
[8]   Abnormalities in beat-to-beat dynamics of heart rate before the spontaneous onset of life-threatening ventricular tachyarrhythmias in patients with prior myocardial infarction [J].
Huikuri, HV ;
Seppanen, T ;
Koistinen, MJ ;
Airaksinen, KEJ ;
Ikaheimo, MJ ;
Castellanos, A ;
Myerburg, RJ .
CIRCULATION, 1996, 93 (10) :1836-1844
[9]   Fifteen years experience with finger arterial pressure monitoring: assessment of the technology [J].
Imholz, BPM ;
Wieling, W ;
van Montfrans, GA ;
Wesseling, KH .
CARDIOVASCULAR RESEARCH, 1998, 38 (03) :605-616
[10]   FEASIBILITY OF AMBULATORY, CONTINUOUS 24-HOUR FINGER ARTERIAL-PRESSURE RECORDING [J].
IMHOLZ, BPM ;
LANGEWOUTERS, GJ ;
VANMONTFRANS, GA ;
PARATI, G ;
VANGOUDOEVER, J ;
WESSELING, KH ;
WIELING, W ;
MANCIA, G .
HYPERTENSION, 1993, 21 (01) :65-73