An adaptive segmentation algorithm for time-of-flight MRA data

被引:139
作者
Wilson, DL
Noble, JA
机构
[1] CSIRO, N Ryde, NSW 1670, Australia
[2] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
关键词
intracranial aneurysms; expectation maximization (EM) algorithm; 3-D segmentation; time-of-flight MR angiography (TOF MRA);
D O I
10.1109/42.811277
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A three-dimensional (3-D) representation of cerebral vessel morphology is essential for neuroradiologists treating cerebral aneurysms, However, current imaging techniques cannot provide such a representation, Slices of MR angiography (MRA) data can only give two-dimensional (2-D) descriptions and ambiguities of aneurysm position and size arising in X-ray projection images can often be intractable, To overcome these problems, we have established a new automatic statistically based algorithm for extracting the 3-D vessel information from time-of-flight (TOF) MRA data. We introduce distributions for the data, motivated by a physical model of blood flow, that are used in a modified version of the expectation maximization (EM) algorithm, The estimated model parameters are then used to classify statistically the voxels into vessel or other brain tissue classes, The algorithm is adaptive because the model fitting is performed recursively so that classifications are made on local subvolumes of data, We present results from applying our algorithm to several real data sets that contain both artery and aneurysm structures of various sizes.
引用
收藏
页码:938 / 945
页数:8
相关论文
共 30 条
[11]   Phase-derivative analysis in MR angiography: Reduced V-enc dependency and improved vessel wall detection in laminar and disturbed flow [J].
Hoogeveen, RM ;
Bakker, CJG ;
Viergever, MA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (02) :321-330
[12]  
KOLLER TM, 1995, FIFTH INTERNATIONAL CONFERENCE ON COMPUTER VISION, PROCEEDINGS, P864, DOI 10.1109/ICCV.1995.466846
[13]  
KRISSIAN K, 1998, 3442 I NAT RECH INF
[14]   PARAMETER-ESTIMATION OF FINITE MIXTURES USING THE EM ALGORITHM AND INFORMATION CRITERIA WITH APPLICATION TO MEDICAL IMAGE-PROCESSING [J].
LIANG, Z ;
JASZCZAK, RJ ;
COLEMAN, RE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :1126-1133
[15]   PARAMETER-ESTIMATION AND TISSUE SEGMENTATION FROM MULTISPECTRAL MR-IMAGES [J].
LIANG, ZR ;
MACFALL, JR ;
HARRINGTON, DP .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (03) :441-449
[16]  
McInerney T, 1997, LECT NOTES COMPUT SC, V1205, P23, DOI 10.1007/BFb0029221
[17]   Improved vessel visualization in MR angiography by nonlinear anisotropic filtering [J].
Orkisz, MM ;
Bresson, C ;
Magnin, IE ;
Champin, O ;
Douek, PC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (06) :914-919
[18]   THRESHOLD SELECTION METHOD FROM GRAY-LEVEL HISTOGRAMS [J].
OTSU, N .
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1979, 9 (01) :62-66
[19]  
PRINET V, 1996, P INT C PATT REC
[20]  
SANDERSON AR, 1996, THESIS U UTAH