High-sensitivity human thyroglobulin (hTG) immunoradiometric assay in the follow-up of patients with differentiated thyroid cancer

被引:28
作者
Giovanella, L
Ceriani, L
机构
[1] Univ Hosp Osped Circolo, Lab Endocrinol & Oncol, I-21100 Varese, Italy
[2] Univ Hosp Osped Circolo, Thyroid Unit, Varese, Italy
[3] Fdn Macchi, Varese, Italy
关键词
thyroid cancer; thyroglobulin; immunoradiometric assay;
D O I
10.1515/CCLM.2002.083
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Circulating human thyroglobulin (hTG) measurement has a pivotal role in the management of patients affected by differentiated thyroid cancer (DTC). Generally, hTG serum concentration less than 1 ng/ml is considered a marker of complete remission after total thyroid ablation. Recently, highsensitivity immunoradiometric assays (IRMA) have been developed to detect very low hTG serum concentrations. The present study was undertaken to test a newly developed highsensitivity hTG IRMA and to evaluate its diagnostic performance and reproducibility in the followup of patients affected by DTC. We retrospectively selected 156 patients without signs of recurrence and 39 patients with DTC recurrence. Serum samples were collected during Lthyroxine (T4) suppressive therapy (ONT4) and 4 weeks after T4 withdrawal (OFFT4), and hTG was measured by a specific highsensitivity IRMA (DYNOtest Tgplus, BRAHMS Diagnostica GmbH, Berlin, Germany). Sera showing the presence of antibodies against hTG (AbhTG) or hTGrecovery less than 80% were excluded from the study. The receiver operator characteristic (ROC) curve analysis was performed to select the best cutoff levels, and diagnostic performance of the marker was evaluated. By using ONT4 cutoff level of 0.2 ng/ml and OFFT4 cutoff level of 0.5 ng/ml we obtained a sensitivity/specificity/accuracy profile of 0.92/0.98/0.97 and 0.97/0.98/0.98, respectively. We found falsenegative results in three (12%) and one (4%) out of 24 patients with cervical recurrence by using 0.2 and 0.5 ng/ml cutoff levels, respectively. However, we found falsenegative results in 13 (54%) and six (25%) patients when 1.0 ng/ml cutoff level was used. Finally, DYNOtest Tgplus showed a very satisfactory intra and interassay reproducibility in the very low hTG concentration range. Based on our data, we conclude that DYNOtest Tgplus assay is effective and accurate in evaluation of patients with DTC.
引用
收藏
页码:480 / 484
页数:5
相关论文
共 15 条
[11]   Serum thyroglobulin determination in the follow-up of patients with differentiated thyroid carcinoma [J].
Schlumberger, M ;
Baudin, E .
EUROPEAN JOURNAL OF ENDOCRINOLOGY, 1998, 138 (03) :249-252
[12]   Medical progress - Papillary and follicular thyroid carcinoma [J].
Schlumberger, MJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (05) :297-306
[13]   Detection of residual and recurrent differentiated thyroid carcinoma by serum thyroglobulin measurement [J].
Spencer, CA ;
LoPresti, JS ;
Fatemi, S ;
Nicoloff, JT .
THYROID, 1999, 9 (05) :435-441
[14]   Serum thyroglobulin measurement -: Utility in clinical practice [J].
Torréns, JI ;
Burch, HB .
ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 2001, 30 (02) :429-+
[15]   Levothyroxine suppression of thyroglobulin in patients with differentiated thyroid carcinoma [J].
Wang, PW ;
Wang, ST ;
Liu, RT ;
Chien, WY ;
Tung, SC ;
Lu, JC ;
Chen, HY ;
Lee, CH .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1999, 84 (12) :4549-4553