A wearable multisensing patch for continuous sweat monitoring

被引:318
作者
Anastasova, Salzitsa [1 ]
Crewther, Blair [1 ,2 ]
Bembnowicz, Pawel [1 ]
Curto, Vincenzo [1 ]
Ip, Henry M. D. [1 ]
Rosa, Bruno [1 ]
Yang, Guang-Zhong [1 ]
机构
[1] Imperial Coll, Hamlyn Ctr, Dept Comp, London, England
[2] Natl Res Inst, Inst Sport, Warsaw, Poland
基金
英国工程与自然科学研究理事会;
关键词
Flexible patch; Microfluidic; Sensors; Exercise; Saliva; LACTATE; SENSOR; EXERCISE; PERSPIRATION; DEVICES; FLUIDS;
D O I
10.1016/j.bios.2016.09.038
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In sport, exercise and healthcare settings, there is a need for continuous, non-invasive monitoring of biomarkers to assess human performance, health and wellbeing. Here we report the development of a flexible microfluidic platform with fully integrated sensing for on-body testing of human sweat. The system can simultaneously and selectively measure metabolite (e.g. lactate) and electrolytes (e.g. pH, sodium) together with temperature sensing for internal calibration. The construction of the platform is designed such that continuous flow of sweat can pass through an array of flexible microneedle type of sensors (50 gm diameter) incorporated in a microfluidic channel. Potentiometric sodium ion sensors were developed using a polyvinyl chloride (PVC) functional membrane deposited on an electrochemically deposited internal layer of Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer. The pH sensing layer is based on a highly sensitive membrane of iridium oxide (IrOx). The amperometric-based lactate sensor consists of doped enzymes deposited on top of a semipermeable copolymer membrane and outer polyurethane layers. Real-time data were collected from human subjects during cycle ergometry and treadmill running. A detailed comparison of sodium, lactate and cortisol from saliva is reported, demonstrating the potential of the multi-sensing platform for tracking these outcomes. In summary, a fully integrated sensor for continuous, simultaneous and selective measurement of sweat metabolites, electrolytes and temperature was achieved using a flexible microfluidic platform. This system can also transmit information wirelessly for ease of collection and storage, with the potential for real-time data analytics.
引用
收藏
页码:139 / 145
页数:7
相关论文
共 30 条
[1]   Development of miniature all-solid-state potentiometric sensing system [J].
Anastasova-Ivanova, Salzitsa ;
Mattinen, Ulriika ;
Radu, Aleksandar ;
Bobacka, Johan ;
Lewenstam, Andrzej ;
Migdalski, Jan ;
Danielewskic, Marek ;
Diamond, Dermot .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 146 (01) :199-205
[2]   Cardiopulmonary Exercise Testing in the Clinical Evaluation of Patients With Heart and Lung Disease [J].
Arena, Ross ;
Sietsema, Kathy E. .
CIRCULATION, 2011, 123 (06) :668-680
[3]   Non-invasive wearable electrochemical sensors: a review [J].
Bandodkar, Amay J. ;
Wang, Joseph .
TRENDS IN BIOTECHNOLOGY, 2014, 32 (07) :363-371
[4]   Epidermal tattoo potentiometric sodium sensors with wireless signal transduction for continuous non-invasive sweat monitoring [J].
Bandodkar, Amay J. ;
Molinnus, Denise ;
Mirza, Omar ;
Guinovart, Tomas ;
Windmiller, Joshua R. ;
Valdes-Ramirez, Gabriela ;
Andrade, Francisco J. ;
Schoening, Michael J. ;
Wang, Joseph .
BIOSENSORS & BIOELECTRONICS, 2014, 54 :603-609
[5]   The relationship between exercise intensity and the sweat lactate excretion rate [J].
Buono, Michael J. ;
Lee, Nanette V. L. ;
Miller, Paul W. .
JOURNAL OF PHYSIOLOGICAL SCIENCES, 2010, 60 (02) :103-107
[6]   Lactate in human sweat: a critical review of research to the present day [J].
Derbyshire, Philip J. ;
Barr, Hugh ;
Davis, Frank ;
Higson, Seamus P. J. .
JOURNAL OF PHYSIOLOGICAL SCIENCES, 2012, 62 (06) :429-440
[7]   Transport in two-dimensional paper networks [J].
Fu, Elain ;
Ramsey, Stephen A. ;
Kauffman, Peter ;
Lutz, Barry ;
Yager, Paul .
MICROFLUIDICS AND NANOFLUIDICS, 2011, 10 (01) :29-35
[8]   Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis [J].
Gao, Wei ;
Emaminejad, Sam ;
Nyein, Hnin Yin Yin ;
Challa, Samyuktha ;
Chen, Kevin ;
Peck, Austin ;
Fahad, Hossain M. ;
Ota, Hiroki ;
Shiraki, Hiroshi ;
Kiriya, Daisuke ;
Lien, Der-Hsien ;
Brooks, George A. ;
Davis, Ronald W. ;
Javey, Ali .
NATURE, 2016, 529 (7587) :509-+
[9]   Thin-film IrOx pH microelectrode for microfluidic-based microsystems [J].
Ges, IA ;
Ivanov, BL ;
Schaffer, DK ;
Lima, EA ;
Werdich, AA ;
Baudenbacher, FJ .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (02) :248-256
[10]   THE RELATIVE INFLUENCE OF PHYSICAL-FITNESS, ACCLIMATIZATION STATE, ANTHROPOMETRIC MEASURES AND GENDER ON INDIVIDUAL REACTIONS TO HEAT-STRESS [J].
HAVENITH, G ;
VANMIDDENDORP, H .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1990, 61 (5-6) :419-427