Effects of disinfectant fogging procedure on dust, ammonia concentration, aerobic bacteria and fungal spores in a farrowing-weaning room

被引:12
作者
Costa, Annamaria [1 ]
Colosio, Claudio [2 ]
Gusmara, Claudia [3 ]
Sala, Vittorio [3 ]
Guarino, Marcella [1 ]
机构
[1] Univ Milan, Fac Vet Med, Dept Hlth Anim Sci & Food Safety, I-20133 Milan, Italy
[2] Univ Milan, Dept Hlth Sci, I-20133 Milan, Italy
[3] Univ Milan, Fac Vet Med, Dept Dept Vet Sci & Publ Hlth, I-20133 Milan, Italy
关键词
disinfectant fogging; piggery; dust; ammonia; aerobic bacteria; fungal spores; SWINE; CONTAMINANTS; VENTILATION; EMISSIONS; EXPOSURE; FILTERS; MODEL; HOUSE;
D O I
10.5604/12321966.1120589
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
air quality can be easily degraded by aerial contaminants that can pose a health riskto the pigs and farm workers. This study evaluated the effects of fogging disinfectant procedure on productive performance, ammonia and dust concentration, aerobic bacteria and fungal spores spreading in the farrowing weaning room. Materials and Method. This trial was conducted in 2 identical farrowing-weaning rooms of a piggery. In both rooms, 30 pregnant sows were lodged in individual cages. At 75 days of age, the piglets were moved to the fattening room. In the treated room, with the birth of the first suckling-pig, the fogging disinfection with diluted Virkon S was applied once a day in the experimental room per 15 minutes at 11:00. The fogging disinfectant treatment was switched between rooms at the end of the first trial period. Temperature, relative humidity, dust (TSP-RF fractions and number of particles), ammonia concentration and aerial contaminants (enterococci, Micrococcaeae and fungal spores) were monitored in both rooms. Results. Ammonia concentration reduction induced by fogging disinfection was estimated 18%, total suspended particles and the respirable fraction were significantly lower in the experimental room. Fungal spores resulted in a significant reduction by the fogging procedure, together with dust respirable fraction and fine particulate matter abatement. Conclusions. The fogging disinfection procedure improved air quality in the piggery, thereby enhancing workers and animals health.
引用
收藏
页码:494 / 499
页数:6
相关论文
共 25 条
[11]   Development of a dynamic model to predict PM10 emissions from swine houses [J].
Haeussermann, Angelika ;
Costa, Annamaria ;
Aerts, Jean-Marie ;
Hartung, Eberhard ;
Jungbluth, Thomas ;
Guarino, Marcella ;
Berckmans, Daniel .
JOURNAL OF ENVIRONMENTAL QUALITY, 2008, 37 (02) :557-564
[12]  
Hartung J, 2002, PARTICULATE MATTER IN AND FROM AGRICULTURE, P119
[13]   Assessment of in-vitro efficacy of 1% Virkon® against bacteria, fungi, viruses and spores by means of AFNOR guidelines [J].
Hernández, A ;
Martró, E ;
Matas, L ;
Martín, M ;
Ausina, V .
JOURNAL OF HOSPITAL INFECTION, 2000, 46 (03) :203-209
[14]   Effect of ventilation rate on gradient of aerial contaminants in the confinement pig building [J].
Kim, Ki Youn ;
Ko, Han Jong ;
Kim, Hyeon Tae ;
Kim, Yoon Shin ;
Roh, Young Man ;
Kim, Chi Nyon .
ENVIRONMENTAL RESEARCH, 2007, 103 (03) :352-357
[15]  
MAGHIRANG RG, 1994, T ASAE, V37, P1607, DOI 10.13031/2013.28247
[16]  
Muller B., 1999, THESIS FREIE U BERLI
[17]  
NADIS, 2009, VET REP FOR FEBR 200
[18]   Effect of manure on ammonia emission from a fattening pig house with partly slatted floor [J].
Ni, JQ ;
Vinckier, C ;
Coenegrachts, J ;
Hendriks, J .
LIVESTOCK PRODUCTION SCIENCE, 1999, 59 (01) :25-31
[19]  
Omland O, 2002, ANN AGR ENV MED, V9, P119
[20]   MICROBIAL VALIDATION OF VENT FILTERS [J].
ROBERTSON, JH ;
FRIEBEN, WR .