Effect of ventilation rate on gradient of aerial contaminants in the confinement pig building

被引:17
作者
Kim, Ki Youn [1 ]
Ko, Han Jong
Kim, Hyeon Tae
Kim, Yoon Shin
Roh, Young Man
Kim, Chi Nyon
机构
[1] Hanyang Univ, Inst Ind & Environm Med, Seoul 133791, South Korea
[2] Kyoto Univ, Grad Sch Agr, Kyoto 606, Japan
[3] Yonsei Univ, Coll Med, Inst Occupat Hlth, Seoul 120749, South Korea
关键词
aerial contaminants; confinement pig building; ventilation rate; dust; airborne microorganisms;
D O I
10.1016/j.envres.2006.09.005
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The principal aim of this study was to compare the aerial contaminants concentrations between the levels of ventilation rate and determine the variation pattern of aerial contaminants affected by the ventilation rate. As a result, there was not significant difference in total dust and total airborne microorganisms among three levels of ventilation rate (P > 0.05) whereas the increased ventilation rate lowered the levels of respirable dust and gaseous compounds (P < 0.05). Based on the results, it was concluded that the suspended gases in the confinement pig building generally followed the air streamline formed by the ventilation whereas the ventilation rate had little effect on the gradient of particulates, especially total dust, due to gravity generated by their size and weight. The findings that the concentrations of total airborne microorganisms were not also significantly different among the ventilation rates could be explained in terms of the fact that airborne microorganisms are easily adsorbed on the surface of dust particle. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:352 / 357
页数:6
相关论文
共 24 条
[1]  
ANDERSON JF, 1978, T ASAE, V21, P1169
[2]  
BUNDY DS, 1984, T ASAE, V27, P865
[3]  
BUNDY DS, 1975, T ASAE, V18, P138
[4]   Exposure assessment to airborne endotoxin, dust, ammonia, hydrogen sulfide and carbon dioxide in open style swine houses [J].
Chang, CW ;
Chung, H ;
Huang, CF ;
Su, HJJ .
ANNALS OF OCCUPATIONAL HYGIENE, 2001, 45 (06) :457-465
[5]   Sampling and assay of bioaerosols in the work environment [J].
Crook, B ;
SherwoodHigham, JL .
JOURNAL OF AEROSOL SCIENCE, 1997, 28 (03) :417-426
[6]  
CURTIS SE, 1975, J ANIM SCI, V41, P1502, DOI 10.2527/jas1975.4151502x
[7]   A facility for controlled exposure of pigs to airborne dusts and gases [J].
Demmers, TGM ;
Wathes, CM ;
Richards, PA ;
Teer, N ;
Taylor, LL ;
Bland, V ;
Goodman, J ;
Armstrong, D ;
Chennells, D ;
Done, SH ;
Hartung, J .
BIOSYSTEMS ENGINEERING, 2003, 84 (02) :217-230
[8]   CHARACTERIZATION OF DUSTS COLLECTED FROM SWINE CONFINEMENT BUILDINGS [J].
DONHAM, KJ ;
SCALLON, LJ ;
POPENDORF, W ;
TREUHAFT, MW ;
ROBERTS, RC .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1986, 47 (07) :404-410
[9]   Factors affecting the release and concentration of dust in pig houses [J].
Gustafsson, G .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1999, 74 (04) :379-390
[10]  
HEBER AJ, 1988, T ASAE, V31, P882