On-line sample preconcentration using field-amplified stacking injection in microchip capillary electrophoresis

被引:56
作者
Gong, Maojun
Wehmeyer, Kenneth R.
Limbach, Patrick A.
Arias, Francisco
Heineman, William R.
机构
[1] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
[2] Procter & Gamble Co, Pharmaceut, Hlth Care Res Ctr, Mason, OH 45040 USA
关键词
D O I
10.1021/ac0521798
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Previous reports describing sample stacking on microchip capillary electrophoresis ( ACE) have regarded the microchip channels as a closed system and treated the bulk flow as in traditional capillary electrophoresis. This work demonstrates that the flows arising from the intersection should be investigated as an open system. It is shown that the pressure-driven flows into or from the branch channels due to bulk velocity mismatch in the main channel should not be neglected but can be used for liquid transportation in the channels. On the basis of these concepts, a sample preconcentration scheme was developed in a commercially available single-cross glass chip for ACE. Similar to field-amplified stacking injection in traditional CE, a low conductivity sample buffer plug was introduced into the separation channel immediately before the negatively charged analyte molecules were injected. The detection sensitivity was improved by 94-, 108-, and 160-fold for fluorescein-5-isothiocyanate, fluorescein disodium, and 5-carboxyfluorescein, respectively, relative to a traditional pinched injection. The calibration curves for fluorescein and 5-carboxyfluorescein demonstrated good linearity in the concentration range (1-60 nM) investigated with acceptable reproducibility of migration time and peak height and area ratios ( 4-5% RSD). This preconcentration scheme will be of particular significance to the practical use of ACE in the emerging miniaturized analytical instrumentation.
引用
收藏
页码:3730 / 3737
页数:8
相关论文
共 51 条
[11]  
2-H
[12]   Sample stacking revisited: A personal perspective [J].
Chien, RL .
ELECTROPHORESIS, 2003, 24 (03) :486-497
[13]   ELECTROOSMOTIC PROPERTIES AND PEAK BROADENING IN FIELD-AMPLIFIED CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
HELMER, JC .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1354-1361
[14]   ON-COLUMN SAMPLE CONCENTRATION USING FIELD AMPLIFICATION IN CZE [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :A489-A496
[15]   Electroosmotically induced hydraulic pumping on microchips: Differential ion transport [J].
Culbertson, CT ;
Ramsey, RS ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2000, 72 (10) :2285-2291
[16]  
Dolník V, 2000, ELECTROPHORESIS, V21, P41, DOI 10.1002/(SICI)1522-2683(20000101)21:1<41::AID-ELPS41>3.0.CO
[17]  
2-7
[18]   MICROCHIP ELECTROPHORESIS WITH SAMPLE STACKING [J].
JACOBSON, SC ;
RAMSEY, JM .
ELECTROPHORESIS, 1995, 16 (04) :481-486
[19]   Thousandfold signal increase using field-amplified sample stacking for on-chip electrophoresis [J].
Jung, B ;
Bharadwaj, R ;
Santiago, JG .
ELECTROPHORESIS, 2003, 24 (19-20) :3476-3483
[20]   Development of an on-line preconcentration method for the analysis of pathogenic lipopolysaccharides using capillary electrophoresis - electrospray mass spectrometry - Application to small colony isolates [J].
Li, J ;
Thibault, P ;
Martin, A ;
Richards, JC ;
Wakarchuk, WW ;
van der Wilp, W .
JOURNAL OF CHROMATOGRAPHY A, 1998, 817 (1-2) :325-336