Simultaneous Voltammetry Determination of Dihydroxybenzene Isomers by Nanogold Modified Electrode

被引:65
作者
Han, Lit [1 ]
Hang, Xiaoli [1 ]
机构
[1] Shandong Univ, Sch Chem & Chem Engn, Jinan 250100, Peoples R China
关键词
Nanogold modified electrode; Dihydroxybenzene isomers; Voltammetry; Simultaneous determination; GLASSY-CARBON ELECTRODE; DIRECT ELECTROCHEMISTRY; LIQUID-CHROMATOGRAPHY; GOLD NANOPARTICLES; PHENOLIC-COMPOUNDS; GLUCOSE-OXIDASE; COMPOSITE FILM; BIOSENSOR; CATECHOL; DERIVATIZATION;
D O I
10.1002/elan.200804403
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A convenient electrochemical deposition method to prepare nanogold/glassy carbon modified electrode (nano-Au/GCE) is adopted. In 0.1 mol/L HAc-NaAc buffer solution (pH4.61), the nano-Au/GCE shows an excellent electrocatalytical behavior for the redox of dihydroxybenzene. A simple, rapid and highly selective voltammetry for simultaneous determination of dihydroxybenzene isomers, hydroquinone, catechol, and resorcinol, is developed using the nano-Au/GCE. This method has been applied to the direct determination of the three dihydroxybenzene isomers in artificial wastewater.
引用
收藏
页码:124 / 129
页数:6
相关论文
共 20 条
[1]   Determination of major phenolic compounds in water by reversed-phase liquid chromatography after pre-column derivatization with benzoyl chloride [J].
Asan, A ;
Isildak, I .
JOURNAL OF CHROMATOGRAPHY A, 2003, 988 (01) :145-149
[2]   Amperometric immunosensors based on layer-by-layer assembly of gold nanoparticles and methylene blue on thiourea modified glassy carbon electrode for determination of human chorionic gonadotrophin [J].
Chai, Rong ;
Yuan, Ruo ;
Chai, Yaqin ;
Ou, Chaofeng ;
Cao, Shurui ;
Li, Xuelian .
TALANTA, 2008, 74 (05) :1330-1336
[3]   Simultaneous determination of 5-hydroxyindoles and catechols by high-performance liquid chromatography with fluorescence detection following derivatization with benzylamine and 1,2-diphenylethylenediamine [J].
Fujino, K ;
Yoshitake, T ;
Kehr, J ;
Nohta, H ;
Yamaguchi, M .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1012 (02) :169-177
[4]   Selective determination of dopamine in the presence of high concentration of ascorbic acid using nano-Au self-assembly glassy carbon electrode [J].
Hu, Guang-Zhi ;
Zhang, Da-Peng ;
Wu, Wei-Li ;
Yang, Zhou-Sheng .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2008, 62 (02) :199-205
[5]   Gold nanoelectrode ensembles for the simultaneous electrochemical detection of ultratrace arsenic, mercury, and copper [J].
Jena, Bikash Kumar ;
Raj, C. Retna .
ANALYTICAL CHEMISTRY, 2008, 80 (13) :4836-4844
[6]   A new scheme of hybridization based on the Aunano-DNA modified glassy carbon electrode [J].
Kang, Jingwan ;
Li, Xiaoning ;
Wu, Guofan ;
Wang, Zhihua ;
Lu, Xiaoquan .
ANALYTICAL BIOCHEMISTRY, 2007, 364 (02) :165-170
[7]   Direct electrochemistry of glucose oxidase entrapped in nano gold particles-ionic liquid-N,N-dimethylformamide composite film on glassy carbon electrode and glucose sensing [J].
Li, Jiangwen ;
Yu, Jingjing ;
Zhao, Faqiong ;
Zeng, Baizhao .
ANALYTICA CHIMICA ACTA, 2007, 587 (01) :33-40
[8]   Amperometric biosensor based on coentrapment of enzyme and mediator by gold nanoparticles on indium-tin oxide electrode [J].
Lin, Jiehua ;
Zhang, Lijuan ;
Zhang, Shusheng .
ANALYTICAL BIOCHEMISTRY, 2007, 370 (02) :180-185
[9]   Electrical detection of DNA hybridization:: Three extraction techniques based on interdigitated Al/Al2O3 capacitors [J].
Moreno-Hagelsieb, L. ;
Foultier, B. ;
Laurent, G. ;
Pampin, R. ;
Remacle, J. ;
Raskin, J. -P. ;
Flandre, D. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10) :2199-2207
[10]   A sensitive and selective spectrophotometric estimation of catechol derivatives in pharmaceutical preparations [J].
Nagaraja, P ;
Vasantha, RA ;
Sunitha, KR .
TALANTA, 2001, 55 (06) :1039-1046