Miniature sodium-selective ion-exchange optode with fluorescent pH chromoionophores and tunable dynamic range

被引:133
作者
Shortreed, M
Bakker, E
Kopelman, R
机构
[1] Department of Chemistry, University of Michigan, Ann Arbor
[2] Department of Chemistry, Auburn University, Auburn
关键词
D O I
10.1021/ac960035a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An extension into the fluorescence mode of ion-exchange optodes is described, allowing miniaturization and its concomitant benefits, A micrometer-size, fluorescent fiber-optic sodium sensor is described, based on a highly sodium-selective, crown ether-capped calix[4]arene ionophore, capable of ratiometric operation, Three sensor configurations are given, employing different lipophilic, fluorescent pH chromoionophores (Nile Blue derivatives), demonstrating the ability to improve the detection limit and tune the dynamic range to the desired region of interest, Two of the sensors are of special interest in that their working ranges he within those desired for measuring intracellular cytosolic or blood levels of sodium at the respective physiological pH. These optodes have excellent sodium selectivity, with other physiologically relevant cations (e.g., potassium, calcium, and magnesium) being highly discriminated. Three simple mathematical relationships are given for the three experimentally used fluorescent signal mechanisms (intensity, intensity ratios, and inner-filter or energy transfer effects), permitting visualization on a single graph and enabling direct comparison of the different sensors' optical responses on a common platform. Finally, these optodes measure the sample's sodium activity, rather than the concentration, provided that the sample's pH is measured simultaneously by another sensor, such as a glass electrode.
引用
收藏
页码:2656 / 2662
页数:7
相关论文
共 45 条
  • [1] Ammann, 1986, ION SELECTIVE MICROE
  • [2] PROPERTIES OF PVC BASED MEMBRANES USED IN ION-SELECTIVE ELECTRODES
    ARMSTRONG, RD
    HORVAI, G
    [J]. ELECTROCHIMICA ACTA, 1990, 35 (01) : 1 - 7
  • [3] SELECTIVITY OF ION-SENSITIVE BULK OPTODES
    BAKKER, E
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (17) : 1805 - 1812
  • [4] SYNTHESIS AND CHARACTERIZATION OF NEUTRAL HYDROGEN ION-SELECTIVE CHROMOIONOPHORES FOR USE IN BULK OPTODES
    BAKKER, E
    LERCHI, M
    ROSATZIN, T
    RUSTERHOLZ, B
    SIMON, W
    [J]. ANALYTICA CHIMICA ACTA, 1993, 278 (02) : 211 - 225
  • [5] DETECTION LIMIT OF ION-SELECTIVE BULK OPTODES AND CORRESPONDING ELECTRODES
    BAKKER, E
    WILLER, M
    PRETSCH, E
    [J]. ANALYTICA CHIMICA ACTA, 1993, 282 (02) : 265 - 271
  • [6] SODIUM-SELECTIVE MEMBRANE-ELECTRODE BASED ON P-TERT-BUTYLCALIX[4]ARENE METHOXYETHYLESTER
    CUNNINGHAM, K
    SVEHLA, G
    HARRIS, SJ
    MCKERVEY, MA
    [J]. ANALYST, 1993, 118 (04) : 341 - 345
  • [7] LIFETIME OF NEUTRAL-CARRIER-BASED LIQUID MEMBRANES IN AQUEOUS SAMPLES AND BLOOD AND THE LIPOPHILICITY OF MEMBRANE-COMPONENTS
    DINTEN, O
    SPICHIGER, UE
    CHANIOTAKIS, N
    GEHRIG, P
    RUSTERHOLZ, B
    MORF, WE
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (06) : 596 - 603
  • [8] SENSITIVITY ENHANCEMENT OF FLUORESCENT PH INDICATORS USING PH-DEPENDENT ENERGY-TRANSFER
    GABOR, G
    CHADHA, S
    WALT, DR
    [J]. ANALYTICA CHIMICA ACTA, 1995, 313 (1-2) : 131 - 137
  • [9] SENSITIVITY ENHANCEMENT OF FLUORESCENT PH INDICATORS BY INNER FILTER EFFECTS
    GABOR, G
    WALT, DR
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (08) : 793 - 796
  • [10] Guilbault G. G., 1976, PURE APPL CHEM, V48, P129